Rosemount 499 Series Dissolved Oxygen, Ozone and Chlorine Sensors
Purchase options
From$382.48
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Amperometric sensors for dissolved oxygen, dissolved ozone and free chlorine, with trace-oxygen ranges for boiler water and membrane-and-electrolyte service in the field.
Key features
- Amperometric dissolved oxygen, ozone and free chlorine sensors
- Trace oxygen ranges for boiler and power plant water
- Free chlorine and monochloramine versions for drinking water
- Membrane and electrolyte replaceable in the field
- Flow-through or submersible mounting
- Connects to Rosemount analytical transmitters over shielded cable
Key specifications
- Measurement principle
- Amperometric cell: the gas diffuses through a membrane and is reduced at the electrode, producing a current proportional to concentration
- Accuracy
- ±0.5% of reading for dissolved oxygen at calibration conditions; chlorine accuracy depends on the reference method used
- Process temperature
- 0 to 50 C (32 to 122 F) for standard membranes; high-temperature versions to 70 C
- Process connection
- Flow-through fitting or submersible mounting; 1 in NPT body
- Enclosure rating
- Sensor body rated for continuous immersion; cable and connector IP68
- Output signal
- Microamp sensor current to the transmitter; 4-20 mA at the transmitter output
What the 499 series is
A family of amperometric sensors that measure dissolved oxygen, dissolved ozone or free chlorine by consuming the gas at an electrode and reading the resulting current. The sensor is a complete measuring cell — membrane, electrolyte and electrode — that connects to a transmitter over a shielded cable.
The three variants
The dissolved oxygen sensor covers trace levels for boiler and power plant water as well as percent-level readings in aeration basins. The ozone sensor measures dissolved ozone in potable water disinfection. The chlorine sensors cover free chlorine and monochloramine in drinking water and cooling systems. They share a body and differ in membrane and electrolyte, which is why the model code matters more than the catalogue heading.
Why amperometric
The reading is proportional to the gas diffusing through the membrane, so it responds to the actual concentration rather than to a colour change or a reagent dose. There is no reagent to prepare and no sample conditioning beyond a flow that keeps the membrane wetted.
Installation and maintenance
Mounts in a flow-through fitting or submerged in a tank, with the membrane facing the flow. Maintenance is a membrane and electrolyte change on a schedule, plus a calibration against a reference method; the sensor body itself is reusable.
Where it fits
Drinking water disinfection, wastewater aeration control, cooling water treatment, boiler feedwater and industrial effluent — wherever the dissolved gas is the number the process is controlled on.
Manufacturer reference: Emerson 499 series product data sheets.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Amperometric cell: the gas diffuses through a membrane and is reduced at the electrode, producing a current proportional to concentration |
| Accuracy | ±0.5% of reading for dissolved oxygen at calibration conditions; chlorine accuracy depends on the reference method used |
| Process temperature | 0 to 50 C (32 to 122 F) for standard membranes; high-temperature versions to 70 C |
| Process connection | Flow-through fitting or submersible mounting; 1 in NPT body |
| Enclosure rating | Sensor body rated for continuous immersion; cable and connector IP68 |
| Output signal | Microamp sensor current to the transmitter; 4-20 mA at the transmitter output |
| Power supply | Powered by the transmitter it is connected to |
| Wetted materials | Membrane, electrolyte, gold or silver electrode and a moulded polymer body |
| Diagnostics | Membrane and electrolyte condition inferred from sensor current and slope by the transmitter |
| Certifications | CE; hazardous-area suitability depends on the transmitter and barrier used |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer