Overview
Guided wave radar level transmitter for continuous measurement in tanks and chambers. It reads level and interface up to 50 m (164 ft) with ±3 mm accuracy, works on low-dielectric products, and offers HART, FOUNDATION Fieldbus, PROFIBUS PA or Modbus output.
Key features
- Guided wave radar, so foam and vapour do not disturb the echo
- Level and interface measurement on two-liquid tanks
- Range to 50 m (164 ft) and ±3 mm accuracy on the standard probe
- Coaxial, twin lead and single lead probes for different products
- Two-wire 4-20 mA with HART, FOUNDATION Fieldbus, PROFIBUS PA or Modbus
- SIL 2/3 (IEC 61508), explosion-proof and intrinsically safe options
Key specifications
- Measurement principle
- Guided wave radar (time domain reflectometry) along a probe
- Accuracy
- ±3 mm (0.12 in) on the standard version
- Process temperature
- -40 to 150 C (-40 to 302 F) standard; high-temperature version to 400 C
- Pressure rating
- Depends on flange and probe; up to 100 bar on the high-pressure versions
- Process connection
- Threaded or flanged; coaxial, twin lead or single lead probe
- Enclosure rating
- IP66/IP67; aluminium or stainless steel housing
What this transmitter is
The 5300 is a guided wave radar level transmitter. A probe runs down into the vessel and carries a low-energy microwave pulse; the pulse reflects from the product surface and the electronics converts the travel time into a distance. Because the pulse is guided rather than radiated, foam, vapour and a narrow nozzle do not disturb the reading the way they can on a free-space radar.
Level and interface
The same instrument reports the top level and, on a two-liquid tank, the interface between them — the measurement that matters on separators and on crude or slurry service. Range reaches 50 m (164 ft) depending on the probe, with ±3 mm accuracy on the standard version.
Probe choice
- Coaxial probe: the most tolerant of turbulence and low-dielectric products, and the usual choice for small tanks and chambers.
- Twin lead: for larger vessels and products with a low dielectric constant.
- Single lead: for viscous or coating products where a twin lead would bridge.
Electronics
Two-wire 4-20 mA with HART, FOUNDATION Fieldbus, PROFIBUS PA or Modbus. Setup is done over HART or with the local display, and the echo curve is available for diagnosing a difficult installation.
Safety
SIL 2/3 certification to IEC 61508 is available, together with explosion-proof and intrinsically safe approvals for hazardous areas.
Manufacturer reference: Emerson document 00813-0100-4530.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Guided wave radar (time domain reflectometry) along a probe |
| Accuracy | ±3 mm (0.12 in) on the standard version |
| Process temperature | -40 to 150 C (-40 to 302 F) standard; high-temperature version to 400 C |
| Pressure rating | Depends on flange and probe; up to 100 bar on the high-pressure versions |
| Process connection | Threaded or flanged; coaxial, twin lead or single lead probe |
| Enclosure rating | IP66/IP67; aluminium or stainless steel housing |
| Output signal | Two-wire 4-20 mA HART, FOUNDATION Fieldbus, PROFIBUS PA or Modbus |
| Power supply | Two-wire loop powered, 4-20 mA |
| Wetted materials | 316L stainless steel, Alloy C-276 and PTFE-covered probes |
| Diagnostics | Echo curve and signal-strength diagnostics over HART; local display available |
| Certifications | SIL 2/3 (IEC 61508); explosion-proof, flameproof and intrinsically safe approvals |