Rosemount 628 Universal Gas Sensor
Purchase options
From$323.85
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Hot-swappable gas sensor cartridge for the 928 monitor: EC electrochemical or MP combustible, with calibration stored in the sensor itself.
Key features
- Hot-swappable sensor cartridge for the Rosemount 928 wireless gas monitor, changed in the field without tools
- Technology codes EC electrochemical (H2S, CO, O2) and MP combustible MEMS - the gas decides the technology, so the two are not free combinations
- Gas codes do not look like the chemicals: T02 hydrogen sulfide, A03 oxygen, T04 carbon monoxide, F41 hydrocarbon and hydrogen
- Unit and range follow the gas: percent LEL for combustibles, ppm for H2S and CO, percent by volume for oxygen
- The sensor stores its own calibration and moves between transmitters already calibrated, but must be connected to a 928 to be calibrated
- End-of-life diagnostics exist on the H2S and CO sensors only; the oxygen and combustible cells depend on a scheduled replacement interval
Key specifications
- Accuracy
- By gas as published for the 928 with this sensor: H2S +/-3 ppm or 10 percent of reading, CO +/-6 ppm or 10 percent, O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below, combustible +/-3 percent LEL methane and +/-5 percent LEL hydrogen
- Output signal
- Not applicable; the cartridge reports through the 928 transmitter over WirelessHART. The sensor is a smart device that carries its own calibration data to whichever transmitter it is installed in
- Diagnostics
- End-of-life diagnostics exist on the H2S and CO sensors only. The oxygen and combustible cells carry no life warning, so an O2 monitor depends on a scheduled replacement interval rather than on the instrument reporting its own depletion
- Pressure range
- Not applicable - an ambient air sensor cartridge that samples the atmosphere at the sensor head, with no process connection
- Variants
- Model 628 EC T02 2 F as a typical example. Technology EC (electrochemical) or MP (combustible MEMS); gas T02 hydrogen sulfide, A03 oxygen, T04 carbon monoxide, F41 hydrocarbon and hydrogen; unit 1 percent LEL, 2 ppm, 3 percent by volume; range F 0-100 for H2S, hydrocarbon and hydrogen, D 0-25 for oxygen
- Application
- Replacement and spare gas sensor cartridges for Rosemount 928 wireless gas monitors, and for building a gas mix across a site from one transmitter type
A sensor that remembers its own calibration, and a code that does not look like the gas
The Rosemount 628 is the hot-swappable sensor module for the 928 wireless gas monitor. It is the part that actually measures: an electrochemical cell for toxic gases and oxygen, or a MEMS element for combustible gas, in a sealed cartridge that is changed in the field without tools.
The ordering code, decoded, because it is not guessable
A typical model number is 628 EC T02 2 F. Read left to right, the blocks are:
| Block | Codes |
|---|---|
| Sensor technology | EC electrochemical, MP combustible MEMS |
| Gas type | T02 hydrogen sulfide, A03 oxygen, T04 carbon monoxide, F41 hydrocarbon and hydrogen gases |
| Unit of measurement | 1 percent LEL, 2 ppm, 3 percent by volume |
| Sensor range | F 0–100 (H2S, hydrocarbon, hydrogen), D 0–25 (oxygen) |
The gas codes do not look like the gases they measure. T02 is hydrogen sulfide, A03 is oxygen, T04 is carbon monoxide, F41 is hydrocarbon and hydrogen. A reader who assumes the code encodes the chemistry will mis-order, and the error is silent until the monitor is powered and reading the wrong thing. Treat the table as the specification, not as a mnemonic.
Technology and gas are not free combinations
The two technology codes exist for two different measurement physics, not for two price points. EC is the electrochemical cell used for H2S, CO and O2 — it consumes a tiny current and is the reason a toxic sensor supports a power module life measured in years. MP is the MEMS element for combustible gas, which heats a sensing element and therefore draws milliamps, which is why the same transmitter with a combustible sensor has roughly half the power module life.
So an H2S sensor in MP technology is not a variant — it is not a product. Ordering correctly means choosing the gas first and letting the technology follow, and the unit and range codes then follow from the gas: percent LEL for combustibles, ppm for H2S and CO, percent by volume for oxygen.
The calibration is inside the cartridge
The 628 is a smart sensor: it stores its own calibration data rather than relying on the transmitter. Two consequences that matter operationally, in opposite directions:
- Fleet flexibility. A sensor can be uninstalled from one 928 and installed in another and arrives already calibrated, and the transmitter recognises it automatically. For a site with many monitors, that means sensors can be rotated and managed as a pool rather than tied to a location.
- Calibration needs a transmitter. The sensor must be connected to a 928 to be calibrated — it cannot be calibrated on the bench on its own. So the swap is a field task and the calibration is a separate task that also happens in the field, which changes how maintenance visits are planned.
End-of-life diagnostics, and where they are absent
Built-in end-of-life diagnostics warn when replacement is needed on the H2S and CO sensors. The oxygen and combustible sensors do not carry that feature, and that asymmetry is worth knowing rather than discovering: an O2 cell depletes gradually and its failure mode is a reading that stays plausible, so an oxygen monitor without a life warning depends on a scheduled replacement interval rather than on the instrument telling you.
The physical interface
The module is a sealed cartridge with a bayonet retention, an O-ring seal and a multi-pin connector to the transmitter, changed without tools. The IP66 rating of the assembly depends on the IP filter fitted to the 628 — the rating belongs to the transmitter and sensor together, so a cartridge installed without its filter compromises the enclosure no matter how well the cover is closed.
Where it fits
Spare and replacement sensors for 928 wireless gas monitors on tank farms, wellheads, skids and unmanned rooms, and for building a gas mix across a site from a single transmitter type. Choose the gas first, let technology, unit and range follow, and keep at least one spare per gas in service so a failed sensor is a swap rather than an outage.
Manufacturer reference: Rosemount 628 Universal Gas Sensor Product Data Sheet for ordering codes and ranges; Rosemount 928 Product Data Sheet 00813-0100-4928 for response times, power module life by sensor type and end-of-life diagnostics.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | By gas as published for the 928 with this sensor: H2S +/-3 ppm or 10 percent of reading, CO +/-6 ppm or 10 percent, O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below, combustible +/-3 percent LEL methane and +/-5 percent LEL hydrogen |
| Output signal | Not applicable; the cartridge reports through the 928 transmitter over WirelessHART. The sensor is a smart device that carries its own calibration data to whichever transmitter it is installed in |
| Diagnostics | End-of-life diagnostics exist on the H2S and CO sensors only. The oxygen and combustible cells carry no life warning, so an O2 monitor depends on a scheduled replacement interval rather than on the instrument reporting its own depletion |
| Pressure range | Not applicable - an ambient air sensor cartridge that samples the atmosphere at the sensor head, with no process connection |
| Variants | Model 628 EC T02 2 F as a typical example. Technology EC (electrochemical) or MP (combustible MEMS); gas T02 hydrogen sulfide, A03 oxygen, T04 carbon monoxide, F41 hydrocarbon and hydrogen; unit 1 percent LEL, 2 ppm, 3 percent by volume; range F 0-100 for H2S, hydrocarbon and hydrogen, D 0-25 for oxygen |
| Application | Replacement and spare gas sensor cartridges for Rosemount 928 wireless gas monitors, and for building a gas mix across a site from one transmitter type |
| Mounting | Sealed cartridge with bayonet retention and an O-ring seal, changed in the field without tools and recognised automatically by the transmitter |
| Operating temperature (°C) | By gas: H2S rated to -40 C, CO and O2 to -30 C, combustible limited to +50 C ambient. IP66 of the assembly depends on the IP filter fitted to the 628 |