Overview
WirelessHART acoustic transmitter for steam trap and relief valve monitoring: acoustic level 0-255 counts plus temperature -40 to 260 C, non-intrusive.
Key features
- WirelessHART acoustic transmitter for non-intrusive monitoring of steam traps and pressure relief valves
- Reports acoustic level 0 to 255 counts and process temperature -40 to 260 C (-104 to 500 F) from one device on one radio
- Counts are an arbitrary scale, not a calibrated decibel value - the value is the trend against a baseline captured when the trap or valve was known good
- Mounts on the outside of the pipe with no tapping and no shutdown; the sensor must couple to metal, not insulation
- 2.4 GHz ISM radio sliced into 15 channels, joining an existing WirelessHART mesh
- Power module life 3.8 years at a 4 second update, 8.4 years at 16 seconds and 10 years at a minute or slower
Key specifications
- Accuracy
- Acoustic output is 0 to 255 counts, an arbitrary scale rather than a calibrated decibel value, so the usable information is the trend compared against a baseline captured when the trap or valve was known to be good
- Output signal
- WirelessHART on the 2.4 GHz ISM band sliced into 15 radio channels, reporting acoustic level (0-255 counts) and process temperature (-40 to 260 C / -104 to 500 F) plus status
- Diagnostics
- Detects ultrasonic acoustic events such as leaks and the turbulence from a leaky valve; the published power module life is 3.8 years at a 4 second update, 8.4 years at 16 seconds and 10 years at a minute or slower, so a slow update rate is the right default for trap monitoring
- Pressure range
- Not applicable - the instrument clamps to the outside of the pipe and is not in the pressure boundary; no tapping or shutdown is required to install it
- Variants
- Wireless acoustic transmitter with acoustic waveguide and mounting arrangement for pipe surface coupling; power comes from the black 7.2 V SmartPower module, which is ordered separately
- Application
- Steam trap surveys at plants with hundreds of traps, pressure relief valve monitoring where discharge is hard to see or dangerous to approach, and leak detection on lines that would need scaffolding or access permits to inspect
It listens, and the number alone means nothing
The Rosemount 708 is a WirelessHART acoustic transmitter. It reports two things: an acoustic level from 0 to 255 counts, and a temperature from -40 to 260 °C (-104 to 500 °F). It mounts on the outside of process piping, needs no tapping and no shutdown, and it exists to answer a question that normally costs an inspection round: is this steam trap passing, or is it holding?
The count is not a measurement, and treating it as one is the mistake
Zero to 255 counts is an arbitrary scale, not a calibrated decibel value. What the instrument actually delivers is a pattern over time: a healthy steam trap has a characteristic rhythm as it discharges and re-closes, a failed-open trap produces continuous turbulence, and a blocked trap goes quiet. None of that is readable from a single reading. It is readable from a trend compared against a baseline captured when the trap was known to be good. A plant that installs these devices and never records a healthy baseline has bought a stream of numbers with nothing to compare them to — which is the most common way an acoustic monitoring project underdelivers.
What it detects, in honest terms
The datasheet describes it as ultrasonic acoustic event detection: leaks, and the turbulence generated by a leaky valve. Applied to steam traps and to pressure relief valves, that covers two of the largest silent losses in a steam plant — a trap that fails open passes live steam continuously, and a PRV that weeps is both an energy loss and an environmental compliance issue. The device does not tell you which failure mode; the acoustic signature plus the temperature channel together suggest it, and the decision is still made by someone who knows the trap type.
Installation is the measurement quality
It clamps to the pipe without cutting it, which is what makes a fleet-wide deployment practical — but the placement determines what is heard. The sensor has to couple to the metal, not to insulation, and it should sit where the acoustic path to the event is short and direct. On a trap, that is usually the body or the pipe immediately downstream; on a PRV, downstream where the discharge would be. An instrument strapped to lagging is listening to the lagging.
Temperature as a second channel
The same device reports process temperature over -40 to 260 °C, which matters because the acoustic signature alone is ambiguous. A trap that is silent could be blocked or could be doing its job; the temperature tells you whether the line is live. Having both channels from one instrument on one radio is the practical argument for the 708 over a dedicated acoustic probe.
Radio and life
The radio is WirelessHART on the 2.4 GHz ISM band, sliced into 15 channels, joining an existing mesh. Power comes from the SmartPower module — the black 7.2 V module for this device — and the published life estimate runs 3.8 years at a 4 second update, 8.4 years at 16 seconds and 10 years at a minute or slower. For acoustic monitoring, a fast update is usually unnecessary: a trap failure develops over hours, not seconds, and the difference between 3.8 and 10 years of battery is the difference between a maintenance visit every few years and one the instrument outlives.
Where it fits
Steam trap surveys at plants with hundreds of traps, PRV monitoring where discharge is hard to see or dangerous to approach, and leak detection on lines where a visual inspection would need scaffolding or access permits. It is a monitoring instrument rather than a control instrument: it tells you where to send the fitter, and the value is in the coverage it makes affordable.
Manufacturer reference: Rosemount 708 Wireless Acoustic Transmitter Product Data Sheet 00813-0100-4708, specifications and acoustic output definitions.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Acoustic output is 0 to 255 counts, an arbitrary scale rather than a calibrated decibel value, so the usable information is the trend compared against a baseline captured when the trap or valve was known to be good |
| Output signal | WirelessHART on the 2.4 GHz ISM band sliced into 15 radio channels, reporting acoustic level (0-255 counts) and process temperature (-40 to 260 C / -104 to 500 F) plus status |
| Diagnostics | Detects ultrasonic acoustic events such as leaks and the turbulence from a leaky valve; the published power module life is 3.8 years at a 4 second update, 8.4 years at 16 seconds and 10 years at a minute or slower, so a slow update rate is the right default for trap monitoring |
| Pressure range | Not applicable - the instrument clamps to the outside of the pipe and is not in the pressure boundary; no tapping or shutdown is required to install it |
| Variants | Wireless acoustic transmitter with acoustic waveguide and mounting arrangement for pipe surface coupling; power comes from the black 7.2 V SmartPower module, which is ordered separately |
| Application | Steam trap surveys at plants with hundreds of traps, pressure relief valve monitoring where discharge is hard to see or dangerous to approach, and leak detection on lines that would need scaffolding or access permits to inspect |
| Mounting | Clamps directly to process piping with no cutting or reconfiguration. The sensor has to couple to metal rather than insulation, and should sit close to the acoustic path of the event: the trap body or the pipe just downstream, or downstream of a PRV where discharge would occur |
| Operating temperature (°C) | -40 to 260 C (-104 to 500 F) process temperature reported as a second channel, which resolves the ambiguity of a silent trap: silent could be blocked or could be working, and the temperature says whether the line is live |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer