Rosemount 8600 Series Vortex Flow Meter
Purchase options
From$1,372.73
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Vortex flow meter for liquids, gases and steam: ±0.75% of rate on liquids, 1 in. to 8 in. flanged, temperature compensated saturated steam.
Key features
- Vortex shedding flow meter for liquid, gas and steam service, with no moving parts and no impulse lines
- Accuracy ±0.75% of rate for liquids above Re 20,000 and ±1% for gas and steam above Re 15,000 on digital and pulse outputs
- Flanged sizes 1 in. to 8 in. (DN 25 to 200) for schedules 10, 40, 80 and 160; ASME B16.5 Class 150/300 or EN 1092-1 PN 16/40
- Velocity limits 90,000/rho or 25 ft/s for liquids and 90,000/rho or 250 ft/s for gases, with accuracy widening to ±1.5% above 125 ft/s
- Temperature compensated saturated steam mass flow at ±2.0% of rate, adding 0.08% per 15 psi below 150 psig
- 4-20 mA HART plus optional scalable pulse 0 to 10,000 Hz; process temperature -50 to 250 C standard
Key specifications
- Accuracy
- ±0.75% of rate for liquids above Re 20,000 and ±1% of rate for gas and steam above Re 15,000 on digital and pulse outputs; analog output adds 0.025% of span. Above 125 ft/s the band widens linearly to ±1.5% at 250 ft/s
- Output signal
- 4-20 mA digital HART signal, with an optional scalable pulse output from 0 to 10,000 Hz switching up to 30 Vdc at 120 mA; available variables include volumetric and mass flow, totaliser, shedding frequency and signal strength
- Diagnostics
- Repeatability ±0.2% of actual flow and stability ±0.2% of rate over one year; velocity limits are 90,000/rho or 25 ft/s for liquids and 90,000/rho or 250 ft/s for gases, whichever is smaller
- Pressure range
- Flange style meter rated for ASME B16.5 Class 150 and 300, or EN 1092-1 PN 16 and 40; line sizes 1, 1.5, 2, 3, 4, 6 and 8 in. (DN 25 to 200) for schedules 10, 40, 80 and 160
- Variants
- Flanged style in the seven line sizes with schedule 10/40/80/160 bore options; mass flow for temperature compensated saturated steam at ±2.0% of rate, adding 0.08% per 15 psi below 150 psig
- Application
- Utility and general purpose flow measurement of liquid, gas and steam: steam headers, boiler feedwater, combustion air, natural gas and clean liquid lines. Fluids must be homogeneous and single phase
A vortex meter for utility steam, with the numbers that decide the size
The Rosemount 8600 is a vortex shedding flow meter for liquid, gas and steam service in utility and general-purpose applications. A bluff body in the flow sheds vortices alternately from each side, and the frequency of that shedding is proportional to velocity — so the meter has no moving parts, no impulse lines, and nothing to plug. What it does have is a sizing envelope, and the envelope is where these meters succeed or fail.
Accuracy, stated per fluid and per regime
For liquids at Reynolds numbers above 20,000, flow accuracy is ±0.75 percent of rate on the digital and pulse outputs, with the analog output adding 0.025 percent of span. For gas and steam above Re 15,000 it is ±1 percent of rate, again with the analog adder. Repeatability is ±0.2 percent of actual flow and stability ±0.2 percent of rate over a year. Those figures are conditional on the Reynolds number for a reason: below the threshold the shedding is no longer the clean phenomenon the calibration assumes.
The velocity ceiling nobody reads
Maximum measurable velocity is 90,000/ρ or 25 ft/s for liquids and 90,000/ρ or 250 ft/s for gases, whichever is smaller, with the caveat that above 125 ft/s the accuracy band widens linearly to ±1.5 percent at 250 ft/s. A steam line sized on flow alone can land above that ceiling and still read — it just reads less accurately, which is worse than not reading at all because nothing announces it.
Sizes and ratings
Flanged meters come in 1, 1.5, 2, 3, 4, 6 and 8 inch (DN 25 to DN 200), for process piping schedules 10, 40, 80 and 160. The flange rating is ASME B16.5 Class 150 or 300, or EN 1092-1 PN 16 and 40. Process temperature is -58 to 482 °F (-50 to 250 °C) standard, and the electronics are rated -50 to 185 °F (-46 to 85 °C) where a local indicator is fitted. One installation detail that catches people: the meter is shipped with a schedule 40 bore default, and the actual pipe bore has to be entered with a communicator or AMS — a mismatch between the entered bore and the real pipe biases every reading.
Saturated steam, done properly
The 8600 offers temperature-compensated mass flow for saturated steam, quoted at ±2.0 percent of rate under nominal conditions of 150 psig (10 bar-g) and above; below 150 psig, add 0.08 percent of uncertainty for every 15 psi below that point. Saturated steam is the case where a vortex meter earns its place: the fluid is single-phase, the density is a function of pressure, and a meter that compensates for temperature removes the separate density calculation that a volumetric meter would leave to the control system.
Outputs and the rest of the loop
Output is a 4-20 mA digital HART signal with an optional scalable pulse output from 0 to 10,000 Hz, switching up to 30 Vdc at 120 mA. Available variables include volumetric and mass flow, totaliser, shedding frequency, pulse frequency, signal strength, electronics temperature and, with the MTA option, process temperature and calculated density. Response is under four seconds plus the rated accuracy time from power up, or under seven seconds with the MTA option.
Where it fits
Utility steam headers, boiler feedwater, combustion air, natural gas and clean liquid lines in general-purpose service — anywhere the fluid is single-phase and the pipe is the right size for the velocity. It does not suit dirty fluids, low-flow turndown below the Reynolds threshold, or lines where the velocity ceiling would be crossed; those are the cases where a DP or magnetic meter is the right answer.
Manufacturer reference: Rosemount 8600 Series Vortex Flow Meter Product Data Sheet, functional and performance specifications.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | ±0.75% of rate for liquids above Re 20,000 and ±1% of rate for gas and steam above Re 15,000 on digital and pulse outputs; analog output adds 0.025% of span. Above 125 ft/s the band widens linearly to ±1.5% at 250 ft/s |
| Output signal | 4-20 mA digital HART signal, with an optional scalable pulse output from 0 to 10,000 Hz switching up to 30 Vdc at 120 mA; available variables include volumetric and mass flow, totaliser, shedding frequency and signal strength |
| Diagnostics | Repeatability ±0.2% of actual flow and stability ±0.2% of rate over one year; velocity limits are 90,000/rho or 25 ft/s for liquids and 90,000/rho or 250 ft/s for gases, whichever is smaller |
| Pressure range | Flange style meter rated for ASME B16.5 Class 150 and 300, or EN 1092-1 PN 16 and 40; line sizes 1, 1.5, 2, 3, 4, 6 and 8 in. (DN 25 to 200) for schedules 10, 40, 80 and 160 |
| Variants | Flanged style in the seven line sizes with schedule 10/40/80/160 bore options; mass flow for temperature compensated saturated steam at ±2.0% of rate, adding 0.08% per 15 psi below 150 psig |
| Application | Utility and general purpose flow measurement of liquid, gas and steam: steam headers, boiler feedwater, combustion air, natural gas and clean liquid lines. Fluids must be homogeneous and single phase |
| Mounting | Flanged in-line installation; the meter ships with a schedule 40 bore default, so the actual pipe bore must be entered with a Field Communicator or AMS or every reading is biased |
| Operating temperature (°C) | Process -58 to 482 F (-50 to 250 C) standard; electronics -50 to 185 F (-46 to 85 C) where a local indicator is fitted |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.