Overview
Wafer-style magnetic flowtube that clamps between two existing flanges with alignment spacers, from 1/2 in to 36 in, with PTFE or PFA liners and a choice of electrode materials.
Key features
- Wafer body clamped between existing pipe flanges
- Line sizes from 1/2 in (15 mm) to 36 in (900 mm)
- PTFE or PFA liner with 316L, Hastelloy or tantalum electrodes
- Alignment spacers supplied for centring in the line
- Reference accuracy 0.25% of rate, 0.15% with the high-accuracy option
- Mates with Rosemount 8732 integral or 8712 remote transmitters
What the 8711 is
A wafer magnetic flowtube: the measuring section is a short body that clamps between two existing pipe flanges, with alignment spacers that centre it in the line. Because it carries no flanges of its own, it is lighter and cheaper than a flanged sensor and it fits into the gap a spool piece would occupy.
How a magnetic flowtube measures
A pair of coils drives a field across the pipe bore. The conductive liquid moving through that field produces a voltage at the electrodes proportional to velocity, and the transmitter converts it to flow using the known bore area. Nothing protrudes into the stream, so there is no added pressure drop and no obstruction for solids to catch on.
Choosing the liner and electrodes
The liner is the part that touches the fluid: PTFE for aggressive chemicals and higher temperatures, PFA where a smoother, more chemical-resistant surface is needed. Electrodes follow the fluid — 316L stainless for benign water, Hastelloy or tantalum where chlorides or acids would attack stainless. A wrong pairing shows up as a drifting reading long before it shows up as a leak.
Accuracy and range
The 8700 platform states a reference accuracy of 0.25 % of rate, with an optional high-accuracy build at 0.15 %. Sizes run from 1/2 in (15 mm) to 36 in (900 mm), so the same family covers a dosing line and a main.
Installation
Needs a straight run upstream and downstream, a full pipe, and a ground path through the fluid — the grounding rings or the liner's own grounding arrangement are part of the installation, not an accessory. The flowtube mates with the 8732 integral transmitter or a remote 8712, so the electronics can sit away from a hot or vibrating line.
Manufacturer reference: Emerson document 00813-0100-4444.