Rosemount 8712EM / 8732EM / 8750W Remote Mount Cables
No product images are published for this product yet.
Purchase options
From$58.02
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Remote mount component and combination cables for 8712EM, 8732EM and 8750W transmitters: standard, extended temperature, I.S. electrode and IP68 submersible versions.
Key features
- Remote mount cables for Rosemount 8712EM, 8732EM and 8750W magnetic flowmeter transmitters, sold as component or combination kits
- Electrode conductors 20 AWG and coil conductors 14 AWG, sized for a millivolt signal circuit and a coil drive circuit respectively
- Jacket colour identifies the cable: grey standard temperature, blue intrinsically safe electrode, black extended temperature, black combination IP68
- Standard temperature rated -20 to 75 C (combination -20 to 80 C); extended temperature and I.S. electrode rated -50 to 125 C
- Submersible combination cable is IP68 rated to 33 ft continuous immersion at 80 C dry and 60 C wet
- Component kits now include both coil and electrode cable, so the two types no longer have to be ordered separately
Key specifications
- Accuracy
- Not a measuring device, but the cable sets what the measurement can be: electrode conductors are 20 AWG and coil conductors 14 AWG, and the screening of the electrode pair is what protects a millivolt signal over a long run
- Output signal
- Carries the coil drive current on 14 AWG conductors and the electrode signal on 20 AWG conductors between sensor and transmitter, either as separate component cables or in one combination jacket
- Diagnostics
- Component kits now include both the coil and the electrode cable, so the two no longer have to be ordered separately. Existing installed cable need not be replaced, except that Emerson suggests - but does not require - new cable where I.S. electrodes are used, to comply with NEC colour coding
- Pressure range
- Not applicable - cable assemblies, not pressure-containing parts
- Variants
- Standard: 08732-0065-0001/-0002, with I.S. electrode -0003/-0004. Extended temperature: -1001/-1002, with I.S. electrode -1003/-1004. Combination: -2001/-2002; submersible IP68 -3001/-3002. Feet and metres versions of each
- Application
- Remote-mounted 8712EM, 8732EM and 8750W magnetic flowmeter installations, where the transmitter is not mounted on the sensor - the usual arrangement, since the transmitter goes where it can be read and away from process heat
The cable is part of the flow measurement
These are the remote mount cables for the Rosemount 8712EM, 8732EM and 8750W magnetic flowmeter transmitters: the coil drive cable and the electrode signal cable that run between a sensor in the pipe and a transmitter mounted somewhere convenient. On a magnetic flowmeter the cable is not wiring — it is the connection between a coil that has to be driven with current and an electrode pair that produces a signal measured in millivolts, and those two jobs do not want the same cable.
Two circuits, two conductor sizes
A component kit carries both cables, and the conductor sizes tell you why they are separate: electrode conductors are 20 AWG and coil conductors are 14 AWG. The coil takes the drive current and needs the cross-section to keep the voltage drop tolerable over a long run. The electrode circuit carries the tiny potential difference the flow is inferred from, and needs screening far more than it needs copper. Running both in one jacket is what the combination cable does, and it is a real convenience — but it is a different compromise, not a free upgrade.
The colour is the specification
The jacket colour is not decoration, it is how an installation is inspected:
- Grey — standard temperature, non-I.S., rated -20 to 75 °C (-20 to 80 °C for the combination cable)
- Blue — intrinsically safe electrode cable, -50 to 125 °C
- Black (component) — extended temperature, -50 to 125 °C
- Black (combination) — IP68 submersible, 80 °C dry / 60 °C wet, rated to 33 ft continuous immersion
The blue is the one that matters most. Emerson released an updated intrinsically safe electrode circuit to meet current hazardous area protection requirements, and with it a new cable — so a blue electrode cable is the visible marker that the I.S. circuit is the one installed. On a plant where both exist, the colour is what an inspector reads first, and an old cable on a new I.S. circuit is the mismatch that fails an audit.
What changed, and what did not
The component kits now include both the coil and the electrode cable, so there is no longer a need to order each type separately. Sites with existing cable already in place do not need to replace it — with one exception: where I.S. electrodes are required, Emerson suggests but does not require running new cable to comply with National Electrical Code conventions for wire colour coding. That is an honest distinction worth keeping: the electrical requirement and the colour-code convention are not the same obligation.
Part numbers, so the order is unambiguous
Standard temperature: 08732-0065-0001 (feet), -0002 (metres), with I.S. electrode -0003 and -0004. Extended temperature: -1001 (feet), -1002 (metres), with I.S. electrode -1003 and -1004. Combination cable: -2001 (feet) and -2002 (metres); submersible IP68 to 33 ft: -3001 and -3002.
Where it fits
Any remote-mounted 8712EM, 8732EM or 8750W installation where the transmitter is not on the sensor — which is most of them, because the transmitter is usually mounted where it can be read and where the electronics are not sitting at process temperature. The choice between standard, extended temperature and submersible follows the environment the cable runs through; the choice between component and combination follows the routing.
Manufacturer reference: Rosemount 8712EM / 8732EM / 8750W Electronics Remote Cable Selection Guide 00840-0100-4444, tables 1-2 to 1-4.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device, but the cable sets what the measurement can be: electrode conductors are 20 AWG and coil conductors 14 AWG, and the screening of the electrode pair is what protects a millivolt signal over a long run |
| Output signal | Carries the coil drive current on 14 AWG conductors and the electrode signal on 20 AWG conductors between sensor and transmitter, either as separate component cables or in one combination jacket |
| Diagnostics | Component kits now include both the coil and the electrode cable, so the two no longer have to be ordered separately. Existing installed cable need not be replaced, except that Emerson suggests - but does not require - new cable where I.S. electrodes are used, to comply with NEC colour coding |
| Pressure range | Not applicable - cable assemblies, not pressure-containing parts |
| Variants | Standard: 08732-0065-0001/-0002, with I.S. electrode -0003/-0004. Extended temperature: -1001/-1002, with I.S. electrode -1003/-1004. Combination: -2001/-2002; submersible IP68 -3001/-3002. Feet and metres versions of each |
| Application | Remote-mounted 8712EM, 8732EM and 8750W magnetic flowmeter installations, where the transmitter is not mounted on the sensor - the usual arrangement, since the transmitter goes where it can be read and away from process heat |
| Mounting | Runs between the sensor and the remotely mounted transmitter. Jacket colour identifies the type on sight: grey standard, blue intrinsically safe electrode, black extended temperature, black combination IP68 - which is what an inspector reads first |
| Operating temperature (°C) | Standard temperature -20 to 75 C (-20 to 80 C for the combination cable); extended temperature and I.S. electrode cable -50 to 125 C; submersible combination cable 80 C dry / 60 C wet, IP68 to 33 ft continuous immersion |
Documents
No documents are published for this product yet.
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer