Skip to main content
Sold and shipped by Sproh

Rosemount 8712EM / 8732EM / 8750W Remote Mount Cables

Part number08732-0065ManufacturerEmerson

No product images are published for this product yet.

Purchase options

From$58.02

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Remote mount component and combination cables for 8712EM, 8732EM and 8750W transmitters: standard, extended temperature, I.S. electrode and IP68 submersible versions.

Key features

  • Remote mount cables for Rosemount 8712EM, 8732EM and 8750W magnetic flowmeter transmitters, sold as component or combination kits
  • Electrode conductors 20 AWG and coil conductors 14 AWG, sized for a millivolt signal circuit and a coil drive circuit respectively
  • Jacket colour identifies the cable: grey standard temperature, blue intrinsically safe electrode, black extended temperature, black combination IP68
  • Standard temperature rated -20 to 75 C (combination -20 to 80 C); extended temperature and I.S. electrode rated -50 to 125 C
  • Submersible combination cable is IP68 rated to 33 ft continuous immersion at 80 C dry and 60 C wet
  • Component kits now include both coil and electrode cable, so the two types no longer have to be ordered separately

Key specifications

Accuracy
Not a measuring device, but the cable sets what the measurement can be: electrode conductors are 20 AWG and coil conductors 14 AWG, and the screening of the electrode pair is what protects a millivolt signal over a long run
Output signal
Carries the coil drive current on 14 AWG conductors and the electrode signal on 20 AWG conductors between sensor and transmitter, either as separate component cables or in one combination jacket
Diagnostics
Component kits now include both the coil and the electrode cable, so the two no longer have to be ordered separately. Existing installed cable need not be replaced, except that Emerson suggests - but does not require - new cable where I.S. electrodes are used, to comply with NEC colour coding
Pressure range
Not applicable - cable assemblies, not pressure-containing parts
Variants
Standard: 08732-0065-0001/-0002, with I.S. electrode -0003/-0004. Extended temperature: -1001/-1002, with I.S. electrode -1003/-1004. Combination: -2001/-2002; submersible IP68 -3001/-3002. Feet and metres versions of each
Application
Remote-mounted 8712EM, 8732EM and 8750W magnetic flowmeter installations, where the transmitter is not mounted on the sensor - the usual arrangement, since the transmitter goes where it can be read and away from process heat
See all specifications