Rosemount 8714D Transmitter Calibration Standard
Purchase options
$1,728.71
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Magnetic flowmeter simulator and reference calibration standard for 8712/8732 transmitters, NIST traceable when factory calibrated annually.
Key features
- Magnetic flowmeter simulator used as a reference calibration standard for 8712 and 8732 transmitters
- Verifies transmitter accuracy and supports re-calibration without removing the sensor from the pipe
- NIST traceability depends on factory calibration on a yearly basis, not on a permanent certificate
- Not compatible with the 8712H High-Signal transmitter - check the transmitter model before scheduling
- Connects at the sensor connections and presents a known reference in place of the flowtube
- Handles the annual verification and the corrective adjustment with one instrument
Key specifications
- Accuracy
- A high precision reference standard whose traceability to NIST depends on factory calibration on a yearly basis; the archive document does not publish a numeric accuracy figure, so none is stated here
- Output signal
- Presents a known reference signal at the transmitter's sensor connections in place of the flowtube, so the transmitter's indication and analog output can be compared against it across the range
- Diagnostics
- Separates the transmitter from the sensor: it proves the electronics, coil drive and analog output, but it does not verify the sensor's own calibration factor, which needs a wet calibration or a factory factor
- Pressure range
- Not applicable - bench calibration instrument, no process connection and no wetted parts
- Variants
- Model 8714DQ4 magnetic flowmeter simulator, reference calibration standard; not compatible with the 8712H High-Signal transmitter
- Application
- Verifying and re-calibrating Rosemount magnetic flowmeter transmitters (8712, 8732, 8742) on the bench or in the field, without removing the sensor from the pipe or draining the line
A reference standard, so the transmitter can be proven rather than assumed
The Rosemount 8714D is a magnetic flowmeter simulator built as a calibration standard: it connects to an 8712 or 8732 transmitter where the sensor would, and presents a known, traceable signal. It is what a plant uses to check that a magmeter transmitter still measures what it says it measures, and to recalibrate it when it does not — without removing a sensor from the pipe or emptying a line.
What it is for
A magnetic flowmeter's uncertainty is normally argued from the sensor's calibration factor. On a transmitter that has been in service for years, that argument leaves out the electronics: the coil drive, the electrode amplifier and the analogue output can all drift while the sensor stays exactly as it was. The 8714D replaces the sensor with a known reference, so the transmitter's reading can be compared against a number that has traceability rather than against another transmitter or against a colleague's memory of what it used to read.
Traceability, and the condition attached
Emerson describes the 8714D as a high precision calibration standard, and its traceability to NIST depends on being factory calibrated on a yearly basis — the manufacturer recommends returning it for that calibration rather than treating the original certificate as permanent. That is the honest position for any reference standard: the certificate is valid for the interval it was issued for, and a simulator that has been in a tool bag for five years is a signal source, not a standard.
Compatibility
It connects to the sensor connections of an 8712 or 8732 transmitter, and it is not compatible with the 8712H High-Signal transmitter — a distinction worth checking against the transmitter nameplate before a calibration is scheduled. It is used to verify accuracy and to re-calibrate, so the same instrument covers both the annual check and the corrective action.
How it is used
The procedure is the reverse of commissioning. The transmitter is powered down, the sensor connections are transferred to the simulator, the transmitter is powered up and set to the tube calibration number the simulator presents, and the indicated flow is compared against the simulated value across the range. Any adjustment is made at the transmitter. When the check is complete the sensor is reconnected and the transmitter powered back up, which clears the empty-pipe or signal-fault message that the simulator itself produces.
What it does not do
It does not calibrate the sensor, and it does not prove the sensor's own calibration factor is still right — that requires a wet calibration or a verified calibration factor from the factory. What it isolates is the transmitter, which is the half that drifts and the half that can be checked in an instrument shop on a bench. A calibration programme that uses it should say plainly which half of the loop it has evidence for.
Where it fits
Plants with a fleet of 8712, 8732 or 8742 magnetic flowmeters and a calibration interval to satisfy: water and wastewater, pulp and paper, chemical and food service. It travels to the transmitter rather than the transmitter travelling to a lab, which is what makes an annual verification affordable at a site with a hundred meters.
Manufacturer reference: Rosemount 8700 Series Product Data Sheet 00813-0100-4727 (8714 ordering information) and the Rosemount 8714D Magnetic Flowtube Simulator quick start guide 00825-0100-4764.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | A high precision reference standard whose traceability to NIST depends on factory calibration on a yearly basis; the archive document does not publish a numeric accuracy figure, so none is stated here |
| Output signal | Presents a known reference signal at the transmitter's sensor connections in place of the flowtube, so the transmitter's indication and analog output can be compared against it across the range |
| Diagnostics | Separates the transmitter from the sensor: it proves the electronics, coil drive and analog output, but it does not verify the sensor's own calibration factor, which needs a wet calibration or a factory factor |
| Pressure range | Not applicable - bench calibration instrument, no process connection and no wetted parts |
| Variants | Model 8714DQ4 magnetic flowmeter simulator, reference calibration standard; not compatible with the 8712H High-Signal transmitter |
| Application | Verifying and re-calibrating Rosemount magnetic flowmeter transmitters (8712, 8732, 8742) on the bench or in the field, without removing the sensor from the pipe or draining the line |
| Mounting | Bench or field use with the supplied cable assemblies; the transmitter is powered down, its sensor connections transferred to the simulator, and powered back up against the simulator's calibration number |
| Operating temperature (°C) | Used in ambient workshop and field conditions; no process temperature rating applies because the instrument is never in contact with the process |