Rosemount 9160489 Electrolyte
No product images are published for this product yet.
Purchase options
$61.73
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Electrolyte bottle (9160489) for the Rosemount Hx438 dissolved oxygen sensor, renewed with the membrane and the polished electrode tip.
Key features
- Electrolyte for the Rosemount Hx438 amperometric dissolved oxygen sensor, part number 9160489
- Standalone bottle for sites that renew membranes more often than they use service kits
- Renewed together with the membrane and the polished glass tip, never on its own
- Filled into the membrane cartridge during reassembly with the sensor held membrane-down
- Emerson's Hx438 documentation gives the bottle as 30 ml
- The 9160487 service kit carries 20 ml for a single service
Key specifications
- Diagnostics
- Renew the electrolyte whenever the membrane is replaced: aged electrolyte shows up as lost slope, drift and a reading that is low at the top of the range rather than as a hard failure
- Application
- Electrolyte for the Rosemount Hx438 amperometric dissolved oxygen sensor, supplying the ionic path between the anode and the cathode behind the membrane
- Mounting
- Filled into the membrane cartridge during service, with the sensor held vertically and the membrane pointing down, after the glass tip has been polished
- Kit contents
- One bottle of electrolyte, given as 30 ml in Emerson's Hx438 documentation; the 9160487 service kit carries 20 ml for a single service
- Material of construction
- Aqueous electrolyte solution in a sealed bottle; do not dilute and do not top up a cartridge that still holds old electrolyte
The liquid that makes the measurement possible
The 9160489 is the electrolyte for the Rosemount Hx438 dissolved oxygen sensor — the conductive path between the membrane and the electrodes, and the part that quietly decides whether a freshly fitted membrane produces a correct reading. It is sold as a bottle on its own for sites that renew membranes often enough that the 20 ml in the service kit runs out first.
What electrolyte does in an amperometric sensor
Oxygen diffuses through the membrane and is reduced at the cathode, which produces a small current proportional to oxygen partial pressure. That reaction needs an ionic path between anode and cathode, and the electrolyte is it. As the sensor works, the electrolyte absorbs impurities and its ionic strength shifts; the sensor does not fail suddenly, it loses slope, drifts, and reads low at the top of its range.
When to renew it
Whenever the membrane is replaced, and at the same time as the glass tip is polished — the three are one procedure, and skipping the electrolyte turns a membrane change into a partial service that shows up as an unexplained calibration offset. Emerson's Hx438 documentation gives the bottle as 30 ml; the cartridge is filled from it during reassembly with the sensor held vertically and the membrane pointing down.
Handling
The bottle is a chemical consumable, not a solvent: keep it sealed, do not dilute it, do not top up a cartridge that still holds old electrolyte, and dispose of the residue according to the site's chemical procedure. Contamination by tap water is the most common reason a new membrane reads badly from the first day.
Where it fits
Rosemount Hx438 installations in fermentation, pharmaceutical water and food and beverage vessels, where the sensor is serviced on a schedule rather than replaced. The service kit 9160487 already contains 20 ml; this bottle is the larger standalone supply for a maintenance store that services several sensors.
Manufacturer reference: Rosemount Hx438 Dissolved Oxygen Sensor Quick Start Guide, 00825-0100-3494, spares table.
Specifications
| Attribute | Value |
|---|---|
| Diagnostics | Renew the electrolyte whenever the membrane is replaced: aged electrolyte shows up as lost slope, drift and a reading that is low at the top of the range rather than as a hard failure |
| Application | Electrolyte for the Rosemount Hx438 amperometric dissolved oxygen sensor, supplying the ionic path between the anode and the cathode behind the membrane |
| Mounting | Filled into the membrane cartridge during service, with the sensor held vertically and the membrane pointing down, after the glass tip has been polished |
| Kit contents | One bottle of electrolyte, given as 30 ml in Emerson's Hx438 documentation; the 9160487 service kit carries 20 ml for a single service |
| Material of construction | Aqueous electrolyte solution in a sealed bottle; do not dilute and do not top up a cartridge that still holds old electrolyte |