Rosemount 9210004 Conductivity Standard
No product images are published for this product yet.
Purchase options
$70.43
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Conductivity calibration standard at 2000 uS/cm in a 16 oz bottle, used to calibrate and verify contacting conductivity sensors.
Key features
- 2000 uS/cm conductivity calibration standard
- 16 oz (0.47 L) bottle
- Used to calibrate and verify contacting conductivity cells
- Part of a family that also covers 200, 1000, 1409 and 5000 uS/cm
- Not classified as hazardous; safety data sheet supplied
- Keep closed and at the same temperature as the sensor when calibrating
Key specifications
- Measurement range
- 2000 uS/cm standard; the same family also covers 200, 1000, 1409 and 5000 uS/cm
- Sensor compatibility
- Contacting conductivity cells and their transmitters, including the Rosemount 140, 141, 142 and 150 families
- Application
- Calibrating and verifying contacting conductivity sensors
- Volume
- 16 oz (0.47 L) bottle
- Storage
- Keep the bottle closed between uses and store per the safety data sheet supplied
- Hazard classification
- Not classified as hazardous under 29 CFR 1910.1200 or the HPR, so no labelling is required; handle as a laboratory chemical and follow the safety data sheet
What this standard is
A 2000 µS/cm conductivity calibration standard, supplied in a 16 oz bottle. It is the reference liquid that turns a sensor reading into a known value: dip the cell, let it stabilise, and the difference between the reading and 2000 µS/cm is what the transmitter's calibration is correcting.
Why a standard, and not just a number
A conductivity cell has a nominal cell constant, and the shipped value sits within a tolerance of that nominal — for a contacting cell, often several percent. Calibration against a standard of known conductivity is how that tolerance is removed, and how a cell is checked after cleaning or after a period in a fouling stream. Without the standard, the transmitter is being calibrated against itself.
Using it properly
Rinse the cell with the standard before measuring, keep the bottle closed between uses, and let the standard and the sensor come to the same temperature — conductivity is strongly temperature-dependent, which is why the transmitter compensates and why a cold standard read as if it were warm gives a false error. The safety data sheet is attached; this preparation is not classified as hazardous, but it is a chemical and should be handled as one.
Where it fits
Calibration and verification of contacting conductivity sensors — the Rosemount 140, 141, 142 and 150 families — in water treatment, chemical and power plant laboratories and instrument shops.
Manufacturer reference: Rosemount conductivity standard 9210004, 2000 µS/cm, and its safety data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement range | 2000 uS/cm standard; the same family also covers 200, 1000, 1409 and 5000 uS/cm |
| Sensor compatibility | Contacting conductivity cells and their transmitters, including the Rosemount 140, 141, 142 and 150 families |
| Application | Calibrating and verifying contacting conductivity sensors |
| Volume | 16 oz (0.47 L) bottle |
| Storage | Keep the bottle closed between uses and store per the safety data sheet supplied |
| Hazard classification | Not classified as hazardous under 29 CFR 1910.1200 or the HPR, so no labelling is required; handle as a laboratory chemical and follow the safety data sheet |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer