Rosemount 936 Open Path Toxic Gas Detector

Part number936ManufacturerEmerson

Purchase options

From$4,869.78

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Open path toxic gas detector for H2S or NH3 across up to 60 m: solar-blind UV, under 3 s response, SIL2, heated window.

Key features

  • Open path toxic gas detector for hydrogen sulfide or ammonia, using ultraviolet flash technology across up to 200 ft (60 m)
  • Solar blind: the working band is 200 to 300 nm, below the wavelength the atmosphere lets through at ground level, so sunlight cannot blind it and false alarms cannot come from the sky
  • Response under 3 seconds, under 10 seconds to T90 - the fast number is the alarm, T90 is stabilization, and both belong on the page
  • The gas is fixed when the receiver is ordered: code T26 for H2S or T27 for NH3, not a field setting
  • Distances are shorter than a combustible open path detector reaches - 5 to 16 m, 14 to 40 m, 35 to 60 m - because the absorption being measured sets the achievable path
  • Heated window for snow, ice and condensation, detection retained to 95 percent obscuration, MTBF at least 100,000 hours, and a 256-event recorder

Key specifications

Accuracy
Path-integrated measurement of H2S or NH3 over the installed span. Spectral response 200 to 300 nm, which sits below the solar cut-off at ground level and is why the instrument is solar blind. Response under 3 seconds, under 10 seconds to T90
Output signal
Alarm and fault signalling to the plant gas detection system, with configuration over HART or RS-485 Modbus. Rated SIL2 by TUV and approved for Zone 1 areas (ATEX, IECEx, CSA)
Diagnostics
Built-in event recorder keeps a real-time record of the last 256 events. Stated MTBF of at least 100,000 hours, with a three-year warranty - for an outdoor optical instrument the manufacturer's confidence interval is part of the specification
Pressure range
Not applicable - an open path optical detector with no process connection and no wetted parts
Variants
Receiver gas codes T26 for hydrogen sulfide and T27 for ammonia - the gas is fixed by the receiver ordered, not by a field setting. Source ranges T1 17 to 52 ft (5 to 16 m), T2 46 to 132 ft (14 to 40 m), T3 115 to 200 ft (35 to 60 m). Source and receiver are separate part numbers
Application
Perimeter and fence-line monitoring around H2S and ammonia hazards: sour water and amine units, sulphur recovery, wastewater headworks and digesters, refrigeration plant, and chemical or fertilizer storage where a toxic cloud drifts across an open area