Overview
UV/IR flame detector for hydrocarbon fires: UV 0.185-0.260 um plus IR 4.4-4.6 um, 93 ft range, adjustable delay to 30 s.
Key features
- Ultraviolet/infrared flame detector for hydrocarbon fuel and gas fires, UV 0.185-0.260 um and IR 4.4-4.6 um
- Detection at 1 ft2 pan fire: n-heptane and gasoline 93 ft (28 m), diesel, kerosene, JP5 and IPA 70 ft, methane and LPG 60 ft
- Response typically 5 s with an adjustable time delay up to 30 s for commissioning
- Field of view 100 x 95 degrees; heated optics to clear condensation and icing; automatic and manual built-in test
- Operating -55 to +75 C (-67 to +167 F) with a +85 C option - narrower than the IR3 models at the hot end
- 24 Vdc (18-32 Vdc), 90 mA standby (110 heated), 130 mA alarm (160 heated); MIL-STD-1275B input protection
Key specifications
- Accuracy
- Detection on a 1 ft2 pan fire: n-heptane and gasoline 93 ft (28 m), diesel, kerosene, JP5 and IPA 70 ft (21 m), methane and LPG 60 ft (18 m), alcohol 57 ft (17 m), office paper 33 ft (10 m)
- Output signal
- Twelve terminals with five factory-set wiring options; alarm and fault to the fire and gas panel; 24 Vdc nominal (18-32 Vdc), 90 mA standby and 130 mA alarm, 160 mA alarm with heated window
- Diagnostics
- Automatic and manual built-in test; both UV and IR signatures must agree before an alarm; input protection to MIL-STD-1275B and EMC to EN 61326-3 and EN 61000-6-3
- Pressure range
- Not applicable to the sensing function; housed for hazardous area service and bracket mounted outside the process
- Variants
- 975UR with UV 0.185-0.260 um and IR 4.4-4.6 um; sensitivity set at a 1 ft2 n-heptane pan fire from 28 m; field of view 100 degrees horizontal by 95 vertical; adjustable time delay up to 30 s
- Application
- Hydrocarbon fuel and gas fire detection in turbine and compressor enclosures, loading areas, paint and solvent rooms and fuel storage, where hydrogen and silane are not part of the risk
UV and IR at 4.4 micrometres: the hydrocarbon-specific pair
The Rosemount 975UR is the UV/IR detector aimed strictly at hydrocarbon fuel and gas fires. Its infrared channel sits at 4.4 to 4.6 micrometres — the CO2 emission band that a hydrocarbon flame produces and that a hot metal surface does not — and its ultraviolet channel covers 0.185 to 0.260 micrometres. Both must agree before an alarm, which is the combination that lets a detector sit in a room with welding, sunlight and hot surfaces and still respond to a fuel fire.
What the 4.4 micrometre band buys
The other 975 models look at wider IR windows: the MR uses four bands between 4 and 5 micrometres, the HR four bands between 2 and 5, and the UF an IR channel at 2.5 to 3.0. The UR's narrow 4.4 to 4.6 window is chosen for specificity — it is where hydrocarbon flames are strongest relative to the background — which is also why the UR has no hydrogen or silane range: those fuels do not present the same signature in that band.
Range table, honestly short
On a 1 ft² (0.1 m²) pan fire at the highest sensitivity: n-heptane and gasoline 93 ft (28 m), diesel, kerosene, JP5 and IPA 70 ft (21 m), methane and LPG 60 ft (18 m) on a plume fire, alcohol 57 ft (17 m), polypropylene pellets 60 ft (18 m), office paper 33 ft (10 m). That is a working range for enclosed areas, compressor buildings, turbine halls and loading areas — not the 300 ft of the IR3 models, and the difference is worth knowing before a layout is drawn around it.
Response and confirmation time
Response is typically 5 seconds, and the detector carries an adjustable time delay of up to 30 seconds. That second number is the one commissioning engineers actually use: a short delay rejects a transient (a flash from a furnace door, a welding spark that gets past the UV/IR coincidence), while a long delay protects against a false trip that costs a plant a shift. It is a deliberate setting, not a fault.
Environment, and where it differs from the IR3 models
The UR's temperature range is -55 to +75 °C (-67 to +167 °F), with an option to +85 °C — narrower at the hot end than the -76 to +185 °F of the MR/HR/UF, and a fact to check before specifying a UR into a hot enclosure. Humidity is up to 95 percent non-condensing, short excursions to 100 percent. The optics are heated to clear condensation and icing, and there is an automatic and manual built-in test.
Electrical
Operating voltage is 24 Vdc nominal (18 to 32 Vdc), with standby current up to 90 mA (110 mA with the heated window) and alarm up to 130 mA (160 mA heated). Cable entries are two ¾ inch NPT or two M25 ISO, wiring 12 to 22 AWG, input protection to MIL-STD-1275B and EMC to EN 61326-3 and EN 61000-6-3. Twelve terminals give five factory-set wiring options, which is what lets one detector drop into different fire and gas panel conventions.
Where it fits
Turbine and compressor enclosures, fuel loading areas, paint and solvent rooms, and hydrocarbon storage where the hazard is a fuel fire and hydrogen is not present. Where hydrogen or silane is part of the risk, the 975HR and 975UF carry those channels; where the area is large and open, the IR3 models carry the range.
Manufacturer reference: Rosemount 975UR Ultraviolet Infrared Flame Detector Product Data Sheet, general specifications table.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Detection on a 1 ft2 pan fire: n-heptane and gasoline 93 ft (28 m), diesel, kerosene, JP5 and IPA 70 ft (21 m), methane and LPG 60 ft (18 m), alcohol 57 ft (17 m), office paper 33 ft (10 m) |
| Output signal | Twelve terminals with five factory-set wiring options; alarm and fault to the fire and gas panel; 24 Vdc nominal (18-32 Vdc), 90 mA standby and 130 mA alarm, 160 mA alarm with heated window |
| Diagnostics | Automatic and manual built-in test; both UV and IR signatures must agree before an alarm; input protection to MIL-STD-1275B and EMC to EN 61326-3 and EN 61000-6-3 |
| Pressure range | Not applicable to the sensing function; housed for hazardous area service and bracket mounted outside the process |
| Variants | 975UR with UV 0.185-0.260 um and IR 4.4-4.6 um; sensitivity set at a 1 ft2 n-heptane pan fire from 28 m; field of view 100 degrees horizontal by 95 vertical; adjustable time delay up to 30 s |
| Application | Hydrocarbon fuel and gas fire detection in turbine and compressor enclosures, loading areas, paint and solvent rooms and fuel storage, where hydrogen and silane are not part of the risk |
| Mounting | Bracket mounted with tilt mount and field of view limiter accessories; heated optics clear condensation and icing on the window |
| Operating temperature (°C) | -55 to +75 C (-67 to +167 F) with an option to +85 C; narrower at the hot end than the IR3 models, which run to +85 C as standard |