Rosemount CX1100 In-Situ Oxygen Analyzer

Part numberCX1100ManufacturerEmerson

Purchase options

From$1,891.05

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

In-situ zirconia O2 transmitter for combustion control, 0-23 percent, with no reference air required and a 400 C probe for clean-burning service.

Key features

  • In-situ zirconia oxygen transmitter for combustion control, measuring 0-23 percent O2 directly in the wet flue gas with no sample conditioning system
  • No instrument air required: ambient air diffuses into the probe as the reference, so there is no reference-air line to filter or lose - and no silent wrong-reading failure when it blocks
  • Repeatability 0.1 percent O2 or 1.0 percent of reading, whichever is lower; lowest detectable limit 0.05 percent O2; process temperature effect under 0.3 percent O2 from 25 to 700 C
  • Response to calibration gas is initial under 3 s and T90 in 10 s, while response to a process change depends on gas velocity and particulate loading of the diffuser
  • Maximum process temperature 752 F (400 C), which is what clean-burning applications means; probe lengths 0.5, 1.0 and 2.0 m in 304 stainless steel
  • Separate transmitter with local display, 4-20 mA output, diagnostics and calibration; probe-only option M0 for installations that already have electronics

Key specifications

Accuracy
Repeatability 0.1 percent O2 or 1.0 percent of reading, whichever is lower - the absolute figure governs at high O2 and the proportional figure at low O2. Lowest detectable limit 0.05 percent O2. Process temperature effect under 0.3 percent O2 from 25 to 700 C
Output signal
4-20 mA from the separate transmitter, which also provides the local display, configuration, calibration and diagnostics. Probe-only option M0 is available for installations that already have electronics
Diagnostics
Ambient air diffuses into the probe as the reference, so no instrument air is required. A conventional in-situ probe with a plumbed reference line does not fail visibly when that line blocks - it reads wrong while still producing a signal, which on a combustion trim loop is a fuel cost rather than a fault
Pressure range
Not the governing rating for an in-situ probe: the probe mounts through a flange in a duct or stack and is exposed to the flue at atmospheric or slight draft conditions
Variants
Probe lengths 050 (0.5 m), 100 (1.0 m) and 200 (2.0 m). Probe-only option M0. Calibration accessories include the F1 calibration gas flowmeter. Probe mounting flange and hardware options per the ordering table
Application
Combustion control on gas-fired boilers, process heaters and clean-burning furnaces: excess-air trim for efficiency and low-oxygen operation where the 0.05 percent detection limit matters