Overview
In-situ zirconia O2 transmitter for combustion control, 0-23 percent, with no reference air required and a 400 C probe for clean-burning service.
Key features
- In-situ zirconia oxygen transmitter for combustion control, measuring 0-23 percent O2 directly in the wet flue gas with no sample conditioning system
- No instrument air required: ambient air diffuses into the probe as the reference, so there is no reference-air line to filter or lose - and no silent wrong-reading failure when it blocks
- Repeatability 0.1 percent O2 or 1.0 percent of reading, whichever is lower; lowest detectable limit 0.05 percent O2; process temperature effect under 0.3 percent O2 from 25 to 700 C
- Response to calibration gas is initial under 3 s and T90 in 10 s, while response to a process change depends on gas velocity and particulate loading of the diffuser
- Maximum process temperature 752 F (400 C), which is what clean-burning applications means; probe lengths 0.5, 1.0 and 2.0 m in 304 stainless steel
- Separate transmitter with local display, 4-20 mA output, diagnostics and calibration; probe-only option M0 for installations that already have electronics
Key specifications
- Accuracy
- Repeatability 0.1 percent O2 or 1.0 percent of reading, whichever is lower - the absolute figure governs at high O2 and the proportional figure at low O2. Lowest detectable limit 0.05 percent O2. Process temperature effect under 0.3 percent O2 from 25 to 700 C
- Output signal
- 4-20 mA from the separate transmitter, which also provides the local display, configuration, calibration and diagnostics. Probe-only option M0 is available for installations that already have electronics
- Diagnostics
- Ambient air diffuses into the probe as the reference, so no instrument air is required. A conventional in-situ probe with a plumbed reference line does not fail visibly when that line blocks - it reads wrong while still producing a signal, which on a combustion trim loop is a fuel cost rather than a fault
- Pressure range
- Not the governing rating for an in-situ probe: the probe mounts through a flange in a duct or stack and is exposed to the flue at atmospheric or slight draft conditions
- Variants
- Probe lengths 050 (0.5 m), 100 (1.0 m) and 200 (2.0 m). Probe-only option M0. Calibration accessories include the F1 calibration gas flowmeter. Probe mounting flange and hardware options per the ordering table
- Application
- Combustion control on gas-fired boilers, process heaters and clean-burning furnaces: excess-air trim for efficiency and low-oxygen operation where the 0.05 percent detection limit matters
No reference air, and why that removes a failure nobody can see
The Rosemount CX1100 is an in-situ zirconia oxygen transmitter for combustion control: a probe that sits in the flue or duct and measures 0 to 23 percent O2 directly in the wet gas, with no sample line to heat and no conditioning system to maintain. It is built for clean-burning applications, with a maximum process temperature of 752 °F (400 °C) and probe lengths of 0.5, 1.0 or 2.0 metres.
What a zirconia cell needs, and what this one does not
A zirconia oxygen sensor works by comparing the oxygen partial pressure on two sides of a heated ceramic cell. One side is the process gas. The other is a reference, and in a conventional in-situ probe that reference is instrument air plumbed through a tube to the probe head.
That tube is the maintenance problem. It has to be run, filtered and kept dry; its filter clogs; and when the reference air is lost or restricted, the analyzer does not stop working — it starts reading wrong, quietly, because the cell is still producing a signal, just against a reference that is no longer 20.9 percent oxygen. On a combustion trim loop, an analyzer reading two percent low is not an obvious fault; it is a fuel bill.
The CX1100 requires no instrument air at all: ambient air diffuses into the probe as the reference. There is no reference line to install, filter or lose, and the failure mode described above does not exist in the design. This is the single most useful thing to understand about the product, and it is stated in the ordering table as a footnote rather than a headline.
The repeatability figure, and how to read it
The published repeatability is 0.1 percent O2 or 1.0 percent of reading, whichever is lower. The phrase is doing real work. At a high O2 reading the absolute figure governs: at 20 percent O2, one percent of reading is 0.2 percent, so the quoted 0.1 percent O2 is the tighter number. At a low O2 reading the proportional figure governs: at 2 percent O2, one percent of reading is 0.02 percent, which is tighter than 0.1 percent. In other words the specification never quotes worse than the better of an absolute floor and a proportional figure, which is what you want from a sensor used both for high-fire excess-air work and for low-oxygen trim.
One distinction worth keeping straight: this is repeatability — short-term scatter around a value — and it is not the same as absolute accuracy against a certified gas. The lowest detectable limit is 0.05 percent O2, and the effect of process temperature is stated separately as less than 0.3 percent O2 across 77 to 1292 °F (25 to 700 °C). Three numbers, three different questions.
The 10 second response is to calibration gas, not to the process
The datasheet is unusually honest here and it is worth quoting precisely: initial response to calibration gas in less than 3 seconds, T90 in 10 seconds — and response to process gas changes will vary depending on process gas velocity and particulate loading of the diffuser. A calibration gas arrives at the cell directly and dry; a step change in a flue gas arrives through a sintered diffuser with ash on it, at whatever velocity the duct provides. Anyone who quotes the 10 second figure as the instrument's response to a boiler upset is quoting the wrong test.
The 400 °C limit is the application boundary
A maximum process temperature of 752 °F (400 °C) is what "clean-burning applications" means in practice. A gas-fired boiler, a process heater or a clean-burning furnace sits inside that envelope. A coal or biomass unit with a slagging, ash-laden flue does not, and the answer there is a different probe with a longer, higher-temperature path and a more robust diffuser — not this one pushed harder. Buying the in-situ analyzer for the wrong flue is how an oxygen measurement acquires a reputation it does not deserve.
The rest of the system
The probe is 304 stainless steel on the wetted side with a mounting flange for duct or stack installation, and the transmitter can be supplied separately — the ordering table has a probe-only option (M0) for installations that already have electronics. The transmitter provides the local display, the 4–20 mA output, configuration and calibration, and diagnostics; a calibration gas flowmeter is available as an accessory, because a zirconia cell is calibrated against a known gas rather than trusted indefinitely.
Where it fits
Combustion control on gas-fired boilers, process heaters and clean-burning furnaces: excess-air trim for efficiency, low-oxygen operation where the 0.05 percent detection limit matters, and any installation where running instrument air to a flue probe is the thing that keeps getting deferred. It measures in situ, in the wet gas, so there is no sample conditioning system to own — which on a small or remote combustion source is the whole business case.
Manufacturer reference: Rosemount CX1100 In-Situ Oxygen Transmitter Product Data Sheet 00813-0100-4110 for range, repeatability, response, probe lengths and ordering information.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Repeatability 0.1 percent O2 or 1.0 percent of reading, whichever is lower - the absolute figure governs at high O2 and the proportional figure at low O2. Lowest detectable limit 0.05 percent O2. Process temperature effect under 0.3 percent O2 from 25 to 700 C |
| Output signal | 4-20 mA from the separate transmitter, which also provides the local display, configuration, calibration and diagnostics. Probe-only option M0 is available for installations that already have electronics |
| Diagnostics | Ambient air diffuses into the probe as the reference, so no instrument air is required. A conventional in-situ probe with a plumbed reference line does not fail visibly when that line blocks - it reads wrong while still producing a signal, which on a combustion trim loop is a fuel cost rather than a fault |
| Pressure range | Not the governing rating for an in-situ probe: the probe mounts through a flange in a duct or stack and is exposed to the flue at atmospheric or slight draft conditions |
| Variants | Probe lengths 050 (0.5 m), 100 (1.0 m) and 200 (2.0 m). Probe-only option M0. Calibration accessories include the F1 calibration gas flowmeter. Probe mounting flange and hardware options per the ordering table |
| Application | Combustion control on gas-fired boilers, process heaters and clean-burning furnaces: excess-air trim for efficiency and low-oxygen operation where the 0.05 percent detection limit matters |
| Mounting | Flanged mounting through the duct or stack wall with the probe reaching into the gas stream. Wetted materials are 304 stainless steel. No reference air line has to be run to the probe head |
| Operating temperature (°C) | Maximum process temperature 752 F (400 C), which is what clean-burning applications means in practice. Probe ambient -20 to 70 C. Response to calibration gas is initial under 3 s and T90 in 10 s; response to process changes depends on gas velocity and particulate loading of the diffuser |