Rosemount FCL Free Chlorine Measuring System
Purchase options
From$2,105.22
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Complete free chlorine measuring system: amperometric sensor, constant-head flow chamber and transmitter, set up to work in samples with pH as high as 9.5.
Key features
- Complete free chlorine loop: sensor, flow chamber and transmitter
- Works in samples up to pH 9.5
- Amperometric free chlorine sensor with replaceable membrane and electrolyte
- 4-20 mA or 0-20 mA isolated output with HART
- Profibus DP available for plant networks
- Relay contacts for chlorination control and alarms
Key specifications
- Measurement principle
- Amperometric free chlorine sensor in a constant-head flow chamber
- Accuracy
- Depends on the reference method used for calibration; typically ±2% of reading after a grab-sample calibration
- Process temperature
- 0 to 50 C (32 to 122 F) sample temperature
- Process connection
- Sample inlet and drain on the flow chamber; 1/4 in tubing connections
- Enclosure rating
- Transmitter NEMA 4X; sensor and flow chamber for indoor sample service
- Output signal
- 4-20 mA or 0-20 mA isolated output with HART digital signal; Profibus DP option
What the FCL system is
A complete free chlorine measuring loop: a 499A CL-01 amperometric sensor, a flow-through sample chamber, and a transmitter that reads the sensor and holds the calibration. It arrives as a system because a free chlorine measurement only works when the sample flow, the pH and the sensor are treated as one unit.
Why pH matters, and why this system handles it
Free chlorine exists as HOCl and OCl- in a ratio set by pH. An amperometric sensor responds to both but not equally, so a sample whose pH drifts will read as a chlorine change. The FCL is set up to work in samples up to pH 9.5 by keeping the sample chemistry inside the range the sensor can linearise, which is the point of specifying it as a system rather than a sensor.
What is in the box
Sensor with membrane and electrolyte, constant-head flow chamber, sample tubing and valves, and the transmitter. Installation is a sample tap, a drain, and power — the loop then runs continuously with a defined flow across the membrane.
Outputs
4-20 mA or 0-20 mA isolated output with HART digital signal, and Profibus where the plant runs a fieldbus. Relay contacts drive chlorination pumps or alarm annunciation.
Where it fits
Municipal drinking water disinfection, pool and spa water, cooling towers and food plant wash water — the applications where free chlorine is both the control variable and a regulatory record.
Manufacturer reference: Emerson FCL system product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Amperometric free chlorine sensor in a constant-head flow chamber |
| Accuracy | Depends on the reference method used for calibration; typically ±2% of reading after a grab-sample calibration |
| Process temperature | 0 to 50 C (32 to 122 F) sample temperature |
| Process connection | Sample inlet and drain on the flow chamber; 1/4 in tubing connections |
| Enclosure rating | Transmitter NEMA 4X; sensor and flow chamber for indoor sample service |
| Output signal | 4-20 mA or 0-20 mA isolated output with HART digital signal; Profibus DP option |
| Power supply | 85-265 V AC for the transmitter, four-wire |
| Wetted materials | PVC chamber, acrylic flow cell, membrane and electrolyte in contact with the sample |
| Diagnostics | Sensor current and membrane condition reported by the transmitter, with fault relay |
| Certifications | CE; system approval follows the transmitter and sensor used |