Rosemount Free Chlorine Sensor Fill Solution
No product images are published for this product yet.
Purchase options
$48.16
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Fill solution #4 for amperometric free chlorine sensors, 4 oz (125 ml): 15-40% KCl, roughly five times the strength of the DO solution.
Key features
- Amperometric free chlorine sensor fill solution #4, 4 oz (125 ml) bottle
- Composition 65-85% water, 15-40% potassium chloride and under 0.1% silver chloride
- Roughly five times the KCl of dissolved oxygen fill solution #1 (7.5%), so the two are not interchangeable
- Chloride activity sets the silver/silver chloride reference potential, which is why the wrong bottle reads and then drifts
- Mixture classified H401 toxic to aquatic life and H412 harmful with long lasting effects; spent solution does not go to a drain
- Replace whenever the sensor is opened for membrane or anode service
Key specifications
- Accuracy
- Not a measured property: the solution's chloride activity sets the sensor's reference potential, so it decides whether a calibration holds rather than carrying an accuracy figure of its own
- Output signal
- Not applicable; the solution is the electrolyte between the membrane and the electrodes and carries the ionic current the sensor measures
- Diagnostics
- Mixture classified H401 toxic to aquatic life and H412 harmful with long lasting effects; not a health hazard in normal handling and not flammable, but spent solution is a waste stream and does not go to a drain
- Pressure range
- Not applicable - electrolyte supplied in a 4 oz (125 ml) bottle for sensor service, with no process connection and no pressure rating
- Variants
- Fill solution #4, 4 oz (125 ml). Composition 65-85% water, 15-40% potassium chloride and under 0.1% silver chloride - roughly five times the KCl of the dissolved oxygen solution #1, so the two are not interchangeable
- Application
- Fill solution for Rosemount amperometric free chlorine sensors in drinking water disinfection, distribution networks and cooling water treatment, where the chlorine residual is the control variable
Fill solution #4, and why it is not fill solution #1
This is the electrolyte for Rosemount amperometric free chlorine sensors: solution #4, in a 4 oz (125 ml) bottle. It sits on the same shelf as the dissolved oxygen fill solution and looks identical from the outside, which is exactly the problem it is worth writing a page about — the two are not interchangeable, and the difference is not subtle.
The numbers that separate the two
The published composition of solution #4 is 65 to 85 percent water, 15 to 40 percent potassium chloride and under 0.1 percent silver chloride. The dissolved oxygen solution (#1) is 7.5 percent potassium chloride in water. Same bottle, same label family, roughly five times the salt concentration in one of them. The concentrations are given as ranges because the exact figure is withheld as a trade secret, but the ranges do not overlap — this is not a batch variation, it is a different electrolyte.
Why concentration is a measurement, not a recipe
An amperometric sensor's reading depends on the potential at which its electrodes sit, and that potential is set by the chemistry of the electrolyte in contact with them. Chloride activity is the term that fixes a silver/silver chloride reference; change it and the reference moves, which shifts the operating point of the whole cell. A free chlorine sensor filled with dissolved oxygen solution will produce a reading — it will just be a reading taken at the wrong potential, and it will drift as the electrode equilibrates toward something it was never designed for. That failure looks like a sensor that needs replacing, which is why the wrong bottle costs more than the right one.
Silver chloride, again in a trace quantity
The silver chloride at under 0.1 percent is the same idea as in the other fill solutions and the same reason it matters: it holds the equilibrium at a silver electrode. Its own hazard classification is the strictest thing in the bottle — corrosive to metals and very toxic to aquatic life — despite being present in a fraction of a percent.
Handling
The mixture itself is classified H401, toxic to aquatic life, and H412, harmful to aquatic life with long lasting effects. It is not a health hazard in normal handling and is not flammable, but the disposal route matters: spent solution does not go down a drain. Eye contact calls for rinsing for at least 15 minutes and skin contact for washing the affected area.
Where it fits
Free chlorine measurement in drinking water disinfection, distribution networks and cooling water treatment — the applications where the chlorine residual is the control variable rather than an indicator. It is bought with the sensor's membrane and anode service, and should be replaced whenever the sensor is opened, because the electrolyte that has been in contact with the sample side has had its chance to absorb what the water contains.
Manufacturer reference: Amperometric Sensor Fill #4 safety data sheet (1501051, 062116) for composition, hazard classification and handling.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measured property: the solution's chloride activity sets the sensor's reference potential, so it decides whether a calibration holds rather than carrying an accuracy figure of its own |
| Output signal | Not applicable; the solution is the electrolyte between the membrane and the electrodes and carries the ionic current the sensor measures |
| Diagnostics | Mixture classified H401 toxic to aquatic life and H412 harmful with long lasting effects; not a health hazard in normal handling and not flammable, but spent solution is a waste stream and does not go to a drain |
| Pressure range | Not applicable - electrolyte supplied in a 4 oz (125 ml) bottle for sensor service, with no process connection and no pressure rating |
| Variants | Fill solution #4, 4 oz (125 ml). Composition 65-85% water, 15-40% potassium chloride and under 0.1% silver chloride - roughly five times the KCl of the dissolved oxygen solution #1, so the two are not interchangeable |
| Application | Fill solution for Rosemount amperometric free chlorine sensors in drinking water disinfection, distribution networks and cooling water treatment, where the chlorine residual is the control variable |
| Mounting | Poured into the sensor body during membrane and anode service; replace it whenever the sensor is opened, not only when it fails calibration |
| Operating temperature (°C) | Water based and must not be frozen; store closed and upright, and do not trust a bottle that has frozen and thawed |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer