Rosemount Hx338+ pH Sensor
Purchase options
$253.01
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Pre-pressurized steam-sterilizable pH sensor for sanitary service: 0 to 14 pH, 0 to 140 C, 0 to 6 bar, glass body with FDA-approved EPDM.
Key features
- Pre-pressurized reference electrode resists junction clogging through steam and pressure cycling
- Steam sterilizable and autoclavable, for SIP and CIP pharmaceutical and biotechnology service
- Range 0 to 14 pH with 57 to 59 mV/pH sensitivity at 25 C and an integral Pt-100 RTD
- Operating range 0 to 140 C (32 to 284 F) and 0 to 6 bar in a 12 mm glass body
- Wetted materials glass and FDA-approved EPDM; minimum sample conductivity 100 uS/cm
- PG 13.5 process connection, 120 mm insertion length, Variopol VP6 plug mating with VP8 cables
Key specifications
- Accuracy
- Sensitivity 57 to 59 mV/pH at 25 C (77 F), the theoretical Nernst slope; integral Pt-100 RTD for temperature compensation
- Diagnostics
- Pre-pressurized reference electrode prevents clogging of the diaphragm junction during steam and pressure cycling, the failure mode that otherwise shows as reference drift after sterilization
- Pressure range
- 0 to 6 bar (87 psig)
- Measurement range
- 0 to 14 pH; minimum sample conductivity 100 uS/cm for a stable reference junction potential
- Sensor connection
- PG 13.5 process thread; Variopol VP6 cable plug, compatible with VP8 mating cables (sold separately)
- Application
- Sanitary pH measurement in biotechnology, pharmaceutical and food and beverage processes where the sensor is steam sterilized in place or autoclaved between batches
A pH electrode that is sterilized in place, not replaced after it
The Rosemount Hx338+ is a pre-pressurized pH sensor for sanitary service: glass body, PG 13.5 thread, integral Pt-100 and a reference electrode that keeps its electrolyte under pressure so the diaphragm junction does not plug. It is the version of a pH probe built for vessels that are steamed between batches rather than cleaned with a rag.
Why pre-pressurization matters
A conventional reference electrode slowly leaks electrolyte out through its junction into the process. Under steam and pressure cycling that exchange reverses: process liquid and proteins are pushed into the junction, it clogs, and the sensor's reference potential drifts until the reading is meaningless — usually right after a validation run. Pre-pressurizing the reference reverses the flow at the junction so the sensor pushes out instead of taking in, which is the mechanism behind the claim that it survives SIP and autoclave cycles.
What it measures
0 to 14 pH with a sensitivity of 57 to 59 mV per pH at 25 °C, which is the theoretical Nernst slope and the figure a calibration check should reproduce. The integral Pt-100 gives the transmitter the temperature it needs to compensate; without it, a hot CIP caustic step reads as a pH change instead of a temperature change. Minimum sample conductivity is 100 µS/cm — below that the reference junction cannot establish a stable potential, and this is the specification that most often rules the sensor out of pure-water applications.
Mechanical limits
Operating range is 0 to 140 °C and 0 to 6 bar, in a 12 mm glass body with a 120 mm insertion length. The process connection is PG 13.5; the electrical connection is the Variopol VP6 plug, and it mates with VP8 cables, which lets the cable be disconnected without twisting it off the sensor — a small thing until the third time someone does it.
Materials and approvals
Wetted materials are glass and FDA-approved EPDM. That combination is what makes the sensor usable in biotechnology, pharmaceutical and food and beverage processes where the wetted path has to be documented, not just tolerated.
Where it fits
Fermenters and bioreactors that are steam sterilized in place, pharmaceutical vessels on CIP/SIP cycles, and food processes where the probe sees both cleaning chemicals and process fluid at temperature. For clean-in-place duty in the harshest chemical environments Emerson still directs you to the factory — the sensor is built for steam, not for every solvent.
Manufacturer reference: Rosemount Hx338+ Steam Sterilizable and Autoclavable Pre-Pressurized pH Sensor Product Data Sheet, February 2025, and Quick Start Guide 00825-0100-3380.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Sensitivity 57 to 59 mV/pH at 25 C (77 F), the theoretical Nernst slope; integral Pt-100 RTD for temperature compensation |
| Diagnostics | Pre-pressurized reference electrode prevents clogging of the diaphragm junction during steam and pressure cycling, the failure mode that otherwise shows as reference drift after sterilization |
| Pressure range | 0 to 6 bar (87 psig) |
| Measurement range | 0 to 14 pH; minimum sample conductivity 100 uS/cm for a stable reference junction potential |
| Sensor connection | PG 13.5 process thread; Variopol VP6 cable plug, compatible with VP8 mating cables (sold separately) |
| Application | Sanitary pH measurement in biotechnology, pharmaceutical and food and beverage processes where the sensor is steam sterilized in place or autoclaved between batches |
| Mounting | Insertion length 120 mm (4.7 in.); fitted directly into a vessel port or through an insertion mounting assembly |
| Material of construction | Glass body 12 mm (0.5 in.) diameter with FDA-approved EPDM seals; pre-pressurized reference electrolyte |
| Operating temperature (°C) | 0 to 140 C (32 to 284 F) |