Rosemount Model 140 Conductivity Sensor
Purchase options
From$921.37
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Retractable contacting conductivity sensor for moderate to high conductivity, withdrawn through a 1 in full-port ball valve, with 0.2/cm or 1.0/cm cell constants.
Key features
- Retractable contacting conductivity sensor, withdraws through a 1 in full-port ball valve
- 0.2/cm and 1.0/cm cell constants, nominal within ±5%
- 316 SST electrodes and body, PEEK insulator, Viton O-rings
- 0 to 150 C standard, 0 to 200 C high-temperature construction
- 100 psig maximum working and retraction pressure
- 1 in MPT connection; valve and cable ordered separately
Key specifications
- Process temperature
- 0 to 150 C (32 to 302 F) standard; 0 to 200 C (32 to 392 F) with the high-temperature construction
- Pressure rating
- 100 psig (791 kPa abs) maximum, and the same 100 psig as maximum retraction pressure
- Process connection
- 1 in MPT, used through a 1 in full-port ball valve for retraction
- Wetted materials
- 316 SST electrodes and body, PEEK insulator, Viton O-rings
- Measurement range
- Moderate to high conductivity ranges through a 0.2/cm or 1.0/cm cell constant
- Cable connection
- Cast-aluminium junction box on the sensor; the interconnecting cable and the ball valve/retraction assembly are ordered separately
What the 140 is
A retractable contacting conductivity sensor: it mounts through a 1 in full-port ball valve so the probe can be withdrawn from a live line, cleaned or replaced, and pushed back without draining the process. That capability is the whole difference between this model and the screw-in 141 — the cell itself is the same family, rated for moderate to high conductivity.
When retraction is worth it
A contacting cell fouls, and the only question is how often. In a line that cannot be shut down — a cooling water header, a process stream feeding a reactor — the choice is either a retraction assembly or a scheduled outage every time the reading drifts. A 140 on a ball valve turns that outage into a two-minute job with the line still running.
What it measures
Moderate to high conductivity through 0.2/cm or 1.0/cm cell constants, nominal to within ±5%. Standard construction covers 0 to 150 C; the high-temperature versions reach 200 C. Maximum pressure and maximum retraction pressure are both 100 psig, which is the number to check before relying on retraction under pressure.
Materials and installation
316 stainless electrodes and body, PEEK insulator, Viton O-rings, cast-aluminium junction box. The sensor threads into 1 in MPT and is used with a 1 in full-port ball valve; the valve/retraction assembly and the interconnecting cable are ordered separately so the length and valve class match the installation.
Where it fits
Cooling water, process water and chemical streams in the moderate to high conductivity band where the sensor has to be serviceable without stopping production.
Manufacturer reference: Emerson 140/141/142 contacting conductivity sensors product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Process temperature | 0 to 150 C (32 to 302 F) standard; 0 to 200 C (32 to 392 F) with the high-temperature construction |
| Pressure rating | 100 psig (791 kPa abs) maximum, and the same 100 psig as maximum retraction pressure |
| Process connection | 1 in MPT, used through a 1 in full-port ball valve for retraction |
| Wetted materials | 316 SST electrodes and body, PEEK insulator, Viton O-rings |
| Measurement range | Moderate to high conductivity ranges through a 0.2/cm or 1.0/cm cell constant |
| Cable connection | Cast-aluminium junction box on the sensor; the interconnecting cable and the ball valve/retraction assembly are ordered separately |
| Application | Cooling water, process water and chemical streams where the sensor must be serviceable without stopping the line |
| Mounting | Retractable: the probe is withdrawn through a ball valve without draining the line |
| Cell constant | 0.2/cm or 1.0/cm, nominal to within ±5% |
| Vacuum | At 1.6 in Hg (5.2 kPa) air leakage is below 0.005 SCFM (0.00014 m3/min) |