Rosemount Model 141 Conductivity Sensor
Purchase options
From$400.71
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Screw-in contacting conductivity sensor for moderate to high conductivity, with 0.2/cm or 1.0/cm cell constants, 316 SST body and a 3/4 in MPT connection.
Key features
- Screw-in contacting conductivity sensor for moderate to high conductivity
- 0.2/cm and 1.0/cm cell constants, nominal within ±5%
- 316 SST electrodes and body, PEEK insulator, Viton O-rings
- 3/4 in MPT process connection
- Cast aluminium junction box, cable ordered separately
- Vacuum service: under 0.005 SCFM leakage at 1.6 in Hg
Key specifications
- Measurement principle
- Contacting (electrode) conductivity in a screw-in body
- Process temperature
- Configuration dependent, plotted in the 140/141/142 pressure and temperature graph
- Pressure rating
- Configuration dependent, from the same pressure and temperature graph
- Process connection
- 3/4 in MPT
- Wetted materials
- 316 SST electrodes and body, PEEK insulator, Viton O-rings
- Measurement range
- Moderate to high conductivity ranges through a 0.2/cm or 1.0/cm cell constant
What the 141 is
A screw-in contacting conductivity sensor for moderate to high conductivity service — the middle of the range, where a general-purpose cell with a 0.2/cm or 1.0/cm constant does the job without the complications of a toroidal body. It threads into a 3/4 in MPT fitting and is built from 316 stainless with a PEEK insulator, so it handles process water and chemical streams rather than only clean water.
Where it sits in the family
The 142 covers low conductivity with 0.01/cm and 0.1/cm cells; the 141 covers the moderate and high band with 0.2/cm and 1.0/cm. Same body concept, same connection, different electrode geometry — which is why the two are ordered by the conductivity band rather than by the process.
Why the cell constant is quoted to ±5%
The nominal constant is the basis of every reading, so the data sheet states how far the shipped cell can sit from nominal. That ±5% is the part of the error that no amount of transmitter calibration removes; the rest is handled in the calibration against a standard solution.
Limits and installation
Pressure and temperature follow the 140/141/142 graph rather than one headline figure. The sensor carries a cast-aluminium junction box, and the interconnecting cable to the transmitter is ordered separately at the length the installation needs. Vacuum service is covered: at 1.6 in Hg the assembly leaks less than 0.005 SCFM.
Where it fits
Process water, cooling and heating loops, chemical dilution and general industrial conductivity where the reading is in the moderate to high band.
Manufacturer reference: Emerson 140/141/142 contacting conductivity sensors product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Contacting (electrode) conductivity in a screw-in body |
| Process temperature | Configuration dependent, plotted in the 140/141/142 pressure and temperature graph |
| Pressure rating | Configuration dependent, from the same pressure and temperature graph |
| Process connection | 3/4 in MPT |
| Wetted materials | 316 SST electrodes and body, PEEK insulator, Viton O-rings |
| Measurement range | Moderate to high conductivity ranges through a 0.2/cm or 1.0/cm cell constant |
| Cable connection | Cast-aluminium junction box on the sensor; interconnecting cable to the transmitter ordered separately |
| Application | Process water, cooling and heating loops, chemical dilution and general industrial conductivity in the moderate to high band |
| Cell constant | 0.2/cm or 1.0/cm, nominal to within ±5% |
| Vacuum | At 1.6 in Hg (5.2 kPa) air leakage is below 0.005 SCFM (0.00014 m3/min) |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer