Rosemount Model 150 Conductivity Sensor
Purchase options
From$542.38
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Flow-through insertion or submersion contacting conductivity sensor with 1 in MNPT threads, cell constants of 0.1, 0.5 or 1.0 /cm and a 175 psig rating at 38 C.
Key features
- Contacting conductivity sensor with 316 SST electrodes
- Cell constants of 0.1, 0.5 or 1.0 /cm
- Ranges from 0-10 to 0-10,000 uS depending on the analyzer
- 1 in MNPT front and rear threads
- Integral temperature compensation from 0 to 121 C
- 175 psig at 38 C falling to 50 psig at 121 C
Key specifications
- Measurement principle
- Contacting (electrode) conductivity with an integral temperature compensation element
- Process temperature
- Temperature compensation from 0 to 121 C (32 to 250 F)
- Pressure rating
- 175 psig (1,207 kPa abs) at 38 C (100 F), falling to 50 psig (345 kPa abs) at 121 C (250 F)
- Process connection
- 1 in MNPT threads, front and rear
- Wetted materials
- 316 stainless steel electrodes with Tefzel and Viton insulators
- Measurement range
- 0-10 to 0-10,000 uS depending on the cell constant and the analyzer it is paired with
What the 150 is
A contacting conductivity sensor for the everyday water-treatment jobs: boiler blowdown, open recirculating cooling water, and set-point detection where the control band is wide enough that a simple, rugged cell is the right instrument. It screws into a line or a tank wall with 1 in MNPT threads at both ends, or into an optional CPVC tee when the installation is flow-through.
How it measures
Two 316 stainless electrodes sit in a Tefzel and Viton insulator body, and an integral temperature element compensates the reading from 0 to 121 C. Three cell constants — 0.1, 0.5 and 1.0 /cm — cover ranges from 0-10 to 0-10,000 µS depending on the analyzer it is paired with.
Where it is the right choice, and where it is not
This is a set-point sensor, not a wide-range analytical instrument. For high accuracy across a broad conductivity band the ENDURANCE 400 series or the toroidal 200 series is the better fit — and this data sheet says so itself. Choosing the 150 for a cooling tower bleed or a boiler blowdown control point is exactly the case it was designed for.
Limits and connections
Rated 175 psig at 100 F (38 C), falling to 50 psig at 250 F (121 C) — the pressure/temperature curve in the data sheet is the limit, not a single number. A 10 ft four-conductor cable is supplied integral with the sensor.
Where it fits
Boiler blowdown control, cooling tower and open recirculating water, and any set-point conductivity control in a water-treatment skid.
Manufacturer reference: Emerson Model 150 product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Contacting (electrode) conductivity with an integral temperature compensation element |
| Process temperature | Temperature compensation from 0 to 121 C (32 to 250 F) |
| Pressure rating | 175 psig (1,207 kPa abs) at 38 C (100 F), falling to 50 psig (345 kPa abs) at 121 C (250 F) |
| Process connection | 1 in MNPT threads, front and rear |
| Wetted materials | 316 stainless steel electrodes with Tefzel and Viton insulators |
| Measurement range | 0-10 to 0-10,000 uS depending on the cell constant and the analyzer it is paired with |
| Cable connection | Integral 10 ft (3 m) four-conductor cable |
| Variants | Optional 1-1/2 in CPVC tee with 1 in FNPT connections for flow-through installation (code 16) |
| Application | Boiler blowdown, open recirculating cooling water and set-point conductivity control |
| Cell constant | 0.1/cm, 0.5/cm or 1.0/cm |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer