Rosemount Model 226 Conductivity Sensor
Purchase options
From$623.64
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Toroidal conductivity sensor with no electrodes in contact with the liquid, covering 1 uS/cm to 2000 mS/cm in a glass-filled PEEK body rated 248 F and 295 psig.
Key features
- Toroidal (inductive) conductivity sensor with no electrodes in the liquid
- 1 uS/cm to 2000 mS/cm range
- Nominal cell constant 1.2/cm, calibrated for ±1% of reading accuracy
- Glass-filled PEEK body and EPDM gasket
- 248 F (120 C) and 295 psig limits
- Large bore for fouling and high-solids streams
Key specifications
- Measurement principle
- Toroidal (inductive): one coil drives an alternating field through the liquid, the other reads the induced current; no electrode contacts the process
- Accuracy
- ±1% of reading ±5 uS/cm from 5 uS/cm to 500 mS/cm after calibration with a Rosemount 56 or 1056 transmitter; wider outside that band
- Process temperature
- 248 F (120 C) maximum
- Pressure rating
- 295 psig (2,135 kPa abs)
- Wetted materials
- Glass-filled PEEK body with an EPDM gasket
- Measurement range
- 1 uS/cm to 2000 mS/cm
What the 226 is
A toroidal conductivity sensor with no electrodes in contact with the liquid. Two encapsulated coils sit in a large bore: one drives an alternating field through the solution, the other reads the current it induces, and the coupling is proportional to conductivity. Because nothing metal touches the process, the failure modes that plague contacting sensors — fouling, polarisation, corrosion of the electrode surface — largely stop applying.
Why toroidal for harsh service
A contacting conductivity cell measures through electrode surfaces that must stay clean and polarisation-free. In a brine, a caustic stream, a pulp stock or an acid with suspended solids, those surfaces foul within days and the reading drifts until someone cleans them. The 226 measures through the wall of a PEEK bore instead, so the same stream that would blind an electrode passes through without touching anything.
Range and accuracy
Covers 1 µS/cm to 2000 mS/cm. The nominal cell constant is 1.2/cm with roughly ±10% error before calibration; after calibration against a 56 or 1056 transmitter the loop holds ±1% of reading ±5 µS/cm between 5 µS/cm and 500 mS/cm, widening outside that band. Calibration is not optional at these accuracies — the sensor is calibrated in place or against a grab sample.
Installation
Immersion or in-line in a tee. Keep the bore at least 1.5 in (40 mm) from the nearest pipe wall: closer than that and the wall changes the field, which shifts the reading in a direction that depends on the wall material.
Limits and where it fits
Glass-filled PEEK body with an EPDM gasket, rated 248 F (120 C) and 295 psig. Chemical and pulp streams, brine and caustic service, and cooling water where a contacting sensor would foul.
Manufacturer reference: Emerson toroidal conductivity sensor addendum and Model 226 manual.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Toroidal (inductive): one coil drives an alternating field through the liquid, the other reads the induced current; no electrode contacts the process |
| Accuracy | ±1% of reading ±5 uS/cm from 5 uS/cm to 500 mS/cm after calibration with a Rosemount 56 or 1056 transmitter; wider outside that band |
| Process temperature | 248 F (120 C) maximum |
| Pressure rating | 295 psig (2,135 kPa abs) |
| Wetted materials | Glass-filled PEEK body with an EPDM gasket |
| Measurement range | 1 uS/cm to 2000 mS/cm |
| Application | Brine, caustic, acid and pulp streams, and cooling water where a contacting sensor would foul or polarise |
| Mounting | Immersion or in-line in a tee; keep the bore at least 1.5 in (40 mm) from the nearest pipe wall to limit wall effects |
| Cell constant | Nominal 1.2/cm, with about ±10% error before calibration |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer