Rosemount Model 5081 Transmitters
Purchase options
From$1,380.24
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Two-wire explosion-proof transmitter for pH/ORP, conductivity, chlorine, oxygen or ozone sensors, with a local display and a 4-20 mA output carrying HART.
Key features
- Two-wire 4-20 mA transmitter with HART digital signal
- pH/ORP, conductivity, chlorine, oxygen or ozone sensor input
- Explosion-proof and weatherproof field housing
- Local display with front-panel calibration
- Epoxy-painted aluminium or stainless steel enclosure
- Single analogue output proportional to the measurement
Key specifications
- Measurement principle
- Single analytical sensor input converted to a linear 4-20 mA signal
- Accuracy
- ±1% of span for conductivity; pH accuracy is set by the electrode pair and buffer calibration
- Process temperature
- 0 to 100 C (32 to 212 F) for standard sensors; 0 to 200 C (32 to 392 F) for high-temperature versions
- Process connection
- Sensor mounts directly to the housing; process connection per sensor type
- Enclosure rating
- NEMA 4X / IP65, epoxy-painted aluminium or stainless steel
- Output signal
- 4-20 mA with superimposed HART digital signal
What the 5081 is
A two-wire transmitter in an explosion-proof housing that takes a single analytical sensor — pH, ORP, conductivity, chlorine, oxygen or ozone — and puts it on a 4-20 mA loop with HART on top. It is the field-mounted half of a measurement: the sensor screws into the process, the transmitter sits at the measurement point, and the control room sees one analogue signal.
Why field mount
Running a high-impedance pH signal from a wet well back to a rack is where most analytical measurements fail — the cable picks up noise, the junction dries out and the reading drifts. Locating the transmitter at the sensor keeps that signal short and sends a robust 4-20 mA loop the distance instead.
Housing
Explosion-proof and weatherproof, with a local display that shows the measurement and lets a technician calibrate on the spot without opening the control room panel. The enclosure is epoxy-painted aluminium or stainless steel, with the sensor connection made directly to the bottom of the housing.
Configuration
Parameter selection, ranging and calibration are done through the front-panel keys or a HART communicator, so a 5081 in the field can be reconfigured for a different sensor without changing hardware. Output is a single 4-20 mA signal proportional to the measurement.
Where it fits
Water and wastewater plants, cooling towers, chemical processing and any installation where the sensor is outdoors or in a classified area and the analyser rack is far away.
Manufacturer reference: Emerson 5081 transmitter product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Single analytical sensor input converted to a linear 4-20 mA signal |
| Accuracy | ±1% of span for conductivity; pH accuracy is set by the electrode pair and buffer calibration |
| Process temperature | 0 to 100 C (32 to 212 F) for standard sensors; 0 to 200 C (32 to 392 F) for high-temperature versions |
| Process connection | Sensor mounts directly to the housing; process connection per sensor type |
| Enclosure rating | NEMA 4X / IP65, epoxy-painted aluminium or stainless steel |
| Output signal | 4-20 mA with superimposed HART digital signal |
| Power supply | Two-wire, loop powered from the 4-20 mA loop |
| Wetted materials | Set by the sensor selected; housing is epoxy-painted aluminium or stainless steel |
| Diagnostics | Sensor and transmitter diagnostics with HART, plus a local display of measurement and temperature |
| Certifications | Explosion-proof and weatherproof housing; approval class depends on the model ordered |