Rosemount MS Magnetic Flow Meter Sensor
Purchase options
From$1,978.67
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Slurry magnetic flow meter sensor with the 8782 transmitter: stronger signal for solids-laden flow, plus diagnostics that name the actual failure modes.
Key features
- Slurry magnetic flow meter sensor with the Rosemount 8782 wall-mount transmitter: 0.25 percent of rate standard accuracy, 0.15 percent optional
- Built for slurries where solids weaken the electrode signal and particles striking the electrodes add noise - the design answer is increased signal strength rather than a more precise amplifier
- Diagnostics map onto the real failure modes: High Process Noise and Coated Electrode Detection (DS1), Electrode Saturation and Coil Circuit Fault as standard, Smart Meter Verification and 4-20 mA Loop Verification (MV)
- Velocity guidance: abrasive slurries 3-10 ft/s, non-abrasive 5-15 ft/s, and the datasheet explicitly allows a sensor larger or smaller than the adjacent piping to reach that band
- The 8785 Calibration Standard verifies the meter on site, which matters when the sensor is being abraded and pulling it means stopping production
- Electrodes in standard, reference, bullet-nose and flat types; fully welded sensor available for maximum protection
Key specifications
- Accuracy
- 0.25 percent of rate standard reference accuracy, 0.15 percent of rate optional. The same figures as the range's general-purpose sensors - the MS difference is increased signal strength, not a better accuracy class
- Output signal
- 4-20 mA with HART from the 8782 transmitter, with intrinsically safe outputs, process diagnostics and Smart Meter Verification. The transmitter has a 15-button tactile keypad and an optional backlit display
- Diagnostics
- The diagnostic set maps onto the ways a slurry meter fails: High Process Noise names solids striking the electrodes, Coated Electrode Detection names build-up on the electrode, Electrode Saturation names the electrochemical half-cell, and Coil Circuit Fault names the field generator. Together they answer whether a wrong reading comes from the fluid, the electrode, the coil or the cable
- Pressure range
- Set by the flange class and liner selection of the MS sensor, ordered with the Rosemount 8782 wall-mount transmitter or as a sensor for existing electronics
- Variants
- MS slurry sensor with standard, reference, bullet-nose and flat electrodes. Diagnostics available across suites: Electrode Saturation and Coil Circuit Fault as standard, High Process Noise and Coated Electrode Detection in Suite 1 (DS1), commanded and continuous Smart Meter Verification plus 4-20 mA Loop Verification in Suite 2 (MV)
- Application
- Mining and mineral processing slurries, dredge and tailings lines, pulp and paper stock, lime and gypsum slurries, and any conductive fluid carrying solids that would make a general-purpose sensor's reading noisy
On a slurry the signal is small and the noise is large — so the diagnostics matter more than the accuracy
The Rosemount MS is the slurry sensor of the magnetic flow meter range, paired here with the 8782 transmitter: a wall-mounted unit with an optional backlit display and 15-button keypad. Reference accuracy is 0.25 percent of rate standard, 0.15 percent optional — the same figures as the general-purpose sensors in the range. What is different is stated in one line of the overview: increased signal strength, for more precise measurement and reduced process variability.
Why a slurry needs more signal
A magnetic flow meter works from a voltage generated in the fluid, and on a clean liquid that voltage is small but clean. A slurry attacks the measurement from both directions at once. The solids reduce the effective contact between the electrodes and the conductive path, so the signal the electrodes see gets weaker; and the particles striking the electrodes add electrochemical noise on top of it. The measurement that was limited by accuracy on water is limited by signal-to-noise on a slurry, which is why the design answer is a stronger field and a stronger signal rather than a more precise amplifier.
The diagnostics are a map of the failure modes
This is the part worth reading closely, because the diagnostic list is not a list of features — it is a list of the specific ways this meter fails in service:
| Diagnostic | The failure it names |
|---|---|
| High Process Noise (DS1) | Solids hitting the electrodes — the noise side of the problem |
| Coated Electrode Detection (DS1) | Product built up on the electrode — the signal side |
| Electrode Saturation (standard) | The electrochemical half-cell has been driven out of its usable range |
| Coil Circuit Fault (standard) | The field generator itself — the measurement is invalid regardless of the fluid |
| Smart Meter Verification (MV) | The whole meter's calibration, checked on command or continuously |
| 4–20 mA Loop Verification (MV) | The signal path after the meter, so a wiring fault is not mistaken for a flow problem |
Read together they answer the question a slurry installation actually asks: is the reading I am getting wrong because of the fluid, the electrode, the coil, or the cable? A meter with only "sensor fault" as a diagnostic leaves the technician to work that out by pulling the sensor out of the line.
Sizing, and the instruction people skip
The velocity guidance is the same as the rest of the range — abrasive slurries 3 to 10 ft/s (0.9 to 3.1 m/s), non-abrasive slurries 5 to 15 ft/s (1.5 to 4.6 m/s) — but the datasheet adds a sentence that is easy to miss and decides the installation: it may be necessary to select a flow sensor larger or smaller than the adjacent piping to put the velocity in the recommended range. That is an explicit permission to use reducers or expanders, and on a slurry line it is often the only way to get both a survivable velocity and the flow range the process needs. A meter matched to the pipe diameter is not automatically a correct installation.
Verification without pulling the meter
The 8785 Calibration Standard provides on-site calibration capability and independent verification of the meter's calibration, and it is compatible with the 8782. On a slurry line this is worth more than it sounds: the sensor is being abraded continuously, the electrodes are the parts that change, and the alternative to verifying in place is taking the flow tube out of a line that is probably carrying production. Verification is what turns "the flow reading looks odd" into either a documented pass or a defined repair.
Electrodes and construction
Four electrode types are offered — standard, reference, bullet-nose and flat. The reference electrode gives the fluid an earth reference in unlined or non-conductive pipework; the bullet-nose profile stands proud to resist abrasive wear at the leading edge; the flat electrode suits services where a protruding shape would collect or erode. The sensor is available fully welded for maximum protection, which matters because the coil sits outside the bore and a moisture path into it is how a magmeter dies in a wet or buried location. The sensor is also compatible with the 8707 high-signal sensor electronics.
Where it fits
Mining and mineral processing slurries, dredge and tailings lines, pulp and paper stock, lime and gypsum slurries, dredging, and any conductive fluid carrying solids that would make a general-purpose sensor's reading noisy. Choose the electrode for the abrasion and the chemistry, size the line for the velocity band rather than the pipe, and use the diagnostics as the maintenance plan rather than as something to look at after a bad shift.
Manufacturer reference: Rosemount Slurry Magnetic Flow Meter Product Data Sheet covering the 8782 transmitter and MS sensor, diagnostics suites, velocity guidance and electrode options.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | 0.25 percent of rate standard reference accuracy, 0.15 percent of rate optional. The same figures as the range's general-purpose sensors - the MS difference is increased signal strength, not a better accuracy class |
| Output signal | 4-20 mA with HART from the 8782 transmitter, with intrinsically safe outputs, process diagnostics and Smart Meter Verification. The transmitter has a 15-button tactile keypad and an optional backlit display |
| Diagnostics | The diagnostic set maps onto the ways a slurry meter fails: High Process Noise names solids striking the electrodes, Coated Electrode Detection names build-up on the electrode, Electrode Saturation names the electrochemical half-cell, and Coil Circuit Fault names the field generator. Together they answer whether a wrong reading comes from the fluid, the electrode, the coil or the cable |
| Pressure range | Set by the flange class and liner selection of the MS sensor, ordered with the Rosemount 8782 wall-mount transmitter or as a sensor for existing electronics |
| Variants | MS slurry sensor with standard, reference, bullet-nose and flat electrodes. Diagnostics available across suites: Electrode Saturation and Coil Circuit Fault as standard, High Process Noise and Coated Electrode Detection in Suite 1 (DS1), commanded and continuous Smart Meter Verification plus 4-20 mA Loop Verification in Suite 2 (MV) |
| Application | Mining and mineral processing slurries, dredge and tailings lines, pulp and paper stock, lime and gypsum slurries, and any conductive fluid carrying solids that would make a general-purpose sensor's reading noisy |
| Mounting | Flanged in-line installation. Sizing follows velocity rather than pipe diameter - abrasive slurries 3 to 10 ft/s (0.9 to 3.1 m/s), non-abrasive slurries 5 to 15 ft/s - and the datasheet explicitly allows a sensor larger or smaller than the adjacent piping to reach that band |
| Operating temperature (°C) | Set by the liner and electrode materials selected for the slurry chemistry and temperature; the sensor is available fully welded for maximum protection against moisture ingress |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer