Rosemount MS Magnetic Flow Meter Sensor

Part numberMSManufacturerEmerson

Purchase options

From$1,978.67

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Slurry magnetic flow meter sensor with the 8782 transmitter: stronger signal for solids-laden flow, plus diagnostics that name the actual failure modes.

Key features

  • Slurry magnetic flow meter sensor with the Rosemount 8782 wall-mount transmitter: 0.25 percent of rate standard accuracy, 0.15 percent optional
  • Built for slurries where solids weaken the electrode signal and particles striking the electrodes add noise - the design answer is increased signal strength rather than a more precise amplifier
  • Diagnostics map onto the real failure modes: High Process Noise and Coated Electrode Detection (DS1), Electrode Saturation and Coil Circuit Fault as standard, Smart Meter Verification and 4-20 mA Loop Verification (MV)
  • Velocity guidance: abrasive slurries 3-10 ft/s, non-abrasive 5-15 ft/s, and the datasheet explicitly allows a sensor larger or smaller than the adjacent piping to reach that band
  • The 8785 Calibration Standard verifies the meter on site, which matters when the sensor is being abraded and pulling it means stopping production
  • Electrodes in standard, reference, bullet-nose and flat types; fully welded sensor available for maximum protection

Key specifications

Accuracy
0.25 percent of rate standard reference accuracy, 0.15 percent of rate optional. The same figures as the range's general-purpose sensors - the MS difference is increased signal strength, not a better accuracy class
Output signal
4-20 mA with HART from the 8782 transmitter, with intrinsically safe outputs, process diagnostics and Smart Meter Verification. The transmitter has a 15-button tactile keypad and an optional backlit display
Diagnostics
The diagnostic set maps onto the ways a slurry meter fails: High Process Noise names solids striking the electrodes, Coated Electrode Detection names build-up on the electrode, Electrode Saturation names the electrochemical half-cell, and Coil Circuit Fault names the field generator. Together they answer whether a wrong reading comes from the fluid, the electrode, the coil or the cable
Pressure range
Set by the flange class and liner selection of the MS sensor, ordered with the Rosemount 8782 wall-mount transmitter or as a sensor for existing electronics
Variants
MS slurry sensor with standard, reference, bullet-nose and flat electrodes. Diagnostics available across suites: Electrode Saturation and Coil Circuit Fault as standard, High Process Noise and Coated Electrode Detection in Suite 1 (DS1), commanded and continuous Smart Meter Verification plus 4-20 mA Loop Verification in Suite 2 (MV)
Application
Mining and mineral processing slurries, dredge and tailings lines, pulp and paper stock, lime and gypsum slurries, and any conductive fluid carrying solids that would make a general-purpose sensor's reading noisy