Skip to main content
Sold and shipped by Sproh

Rosemount Oxymitter 4000 Hazardous Area Oxygen Transmitter

Part numberOXT4CManufacturerEmerson

Purchase options

Request a quote

Availability
Call for availability Originalx
Request Price

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

In-situ zirconia oxygen transmitter for flue gas in hazardous areas: ATEX Exd IIB + H2 T4 Gb, 0-10% to 0-40% O2, process to 800 C with Xi electronics.

Key features

  • In-situ zirconia oxygen transmitter for flue gas in hazardous areas, model OXT4C
  • ATEX II 2G Exd IIB + H2 T4 Gb flameproof housing with through-glass infrared buttons
  • Net O2 range variable 0-10% to 0-40% (0-50% with Xi electronics); accuracy ±0.75% of reading or 0.05% O2
  • Process temperature to 705 C (1300 F), or 800 C with Xi electronics; probe lengths 18 in to 18 ft
  • Response to calibration gas under 3 seconds with T90 inside 8 seconds
  • HART standard, with HART wireless through a THUM adaptor; electronics integral to the probe or remote

Key specifications

Accuracy
+/-0.75% of reading or 0.05% O2, whichever is greater, in oxidizing conditions; +/-0.10% of reading or 0.1% O2 in reducing conditions; process temperature effect below 0.05% O2 from 100 to 700 C
Output signal
4-20 mA with HART digital communication; HART wireless available through a THUM adaptor; optional Xi electronics add a large backlit LCD and advanced software features
Diagnostics
Heater and thermocouple hold the sensing cell at a 736 C setpoint within +/-1 C; the probe is field repairable with access to internal components, and the transmitter has no potentiometers or jumpers to set
Certifications
ATEX II 2G Exd IIB + H2 T4 Gb for the hazardous area version (model OXT4C), in a Type 4X (IP65/IP66) enclosure
Measurement range
Net O2 range variable from 0-10% to 0-40%; the optional Xi electronics extend it to 0-50% O2; lowest detectable limit 0.02% O2
Application
In-situ oxygen measurement in flue gas of boilers, process heaters, furnaces and kilns installed in hazardous (classified) areas, where the O2 reading drives combustion trim
See all specifications