Skip to main content
Sold and shipped by Sproh

Rosemount PowerVUE 8x14 Power Positioner

Part numberPowerVUE 8x14ManufacturerEmerson

Purchase options

From$13,035.37

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Hagan 8x14 floor mounted damper drive with an integral digital valve controller: 4,600 ft-lb stall torque, ±0.5% repeatability, HART or fieldbus.

Key features

  • Hagan 8x14 floor mounted actuator with an integral Fisher FieldVUE digital valve controller
  • Stall torque 4,600 ft-lb (6,238 N·m); friction load 1,100 ft-lb; weight load 1,600 ft-lb; 8 in. stroke and 80 degrees
  • Repeatability ±0.5% of full stroke, against 1% for the pneumatic positioner on the same frame
  • 4-20 mA with HART or FOUNDATION fieldbus; ValveLink and AMS diagnostics with stored as-found signatures
  • Base assembly includes air filter-regulator 4505C21G03, clevis 174469 and manual IB-102-204; 249 kg shipping weight
  • Manual operator limited to 45 psi differential across the piston; heater and limit switch options

Key specifications

Accuracy
Repeatability ±0.5% of full stroke or better, against 1% for the pneumatic positioner on the same frame; unloaded full stroke 2.5 seconds for the 8 in. stroke and 80 degrees of rotation on the pneumatic version
Output signal
Stall torque 4,600 ft-lb (6,238 N·m); maximum friction load 1,100 ft-lb (1,492 N·m); maximum allowable weight load 1,600 ft-lb (2,170 N·m) over an 8 in. stroke producing 80 degrees
Diagnostics
ValveLink and AMS diagnostics through the FieldVUE controller with stored as-found signatures; optional digital electronic position transmitter with two limit contacts on HART versions and two standard SPDT limit switches
Pressure range
Air supply 45 to 120 psig (310 to 827 kPa gauge) with 100 psig recommended; the pneumatic 8x14 uses 2 scfm steady state, and the only published PowerVUE consumption figure is 10 scfm for the 4x5, which is the order of magnitude a digital controller vents continuously
Variants
Standard or mechanical air lock assembly in brass or stainless; digital valve controller as HART, fieldbus with or without basic control suite, or supplied by others; manual operator limited to 45 psi differential across the piston
Application
Primary and secondary air dampers on utility boilers and large industrial furnace dampers too stiff for the 6x10, where the drive must also report position and health to the control room
See all specifications