Rosemount Reagents for Chlorine Analyzers
No product images are published for this product yet.
Purchase options
From$34.60
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Reagent kits for the reagent-based chlorine analysers: total chlorine, free chlorine and buffered variants, matched to the analyser model and measuring range.
Key features
- Reagent kits for reagent-based chlorine analysers
- Total chlorine, free chlorine and buffered variants
- Matched to the analyser model and measuring range
- Supplied in sets sized to the service interval
- Dated and temperature-sensitive — observe storage limits
- Safety data sheet available for handling and disposal
Key specifications
- Measurement principle
- Colorimetric reaction between the reagent and chlorine in the sample
- Accuracy
- Analyser accuracy depends on reagent condition; discard an expired or discoloured kit
- Process temperature
- Store within the range printed on the label; do not freeze
- Process connection
- Bottle and cap sized for the analyser's reagent pump
- Output signal
- Not applicable - the reagent is consumed by the analyser
- Power supply
- Not applicable - consumable
What these reagents are
Consumable reagent kits for the reagent-based chlorine analysers in the Rosemount liquid analysis range. A reagent analyser is only as good as the chemistry it is fed: the reagent sets the reaction time, the colour development and the calibration stability, and an expired or contaminated bottle shows up as a reading that drifts without any instrument fault.
Which analyser uses which kit
The part number is specific to the analyser and the measurement: total chlorine for the TCL, free chlorine for the CL17 and FCL systems, and the buffered variants for samples with a high or variable pH. Ordering the wrong kit does not damage the analyser, but it will not produce a valid result, which is why the analyser model and range are quoted with every order.
Storage and life
Reagents are dated and temperature-sensitive. Keep them in the shaded conditions printed on the label, respect the expiry date and discard a bottle that has changed colour before its time — a reagent problem is the most common cause of a slow drift that looks like an instrument fault.
Ordering
Supplied as a set sized to the analyser's consumption over its normal service interval. Include the analyser model and the parameter when ordering so the correct kit is picked.
Manufacturer reference: Emerson reagent safety data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Colorimetric reaction between the reagent and chlorine in the sample |
| Accuracy | Analyser accuracy depends on reagent condition; discard an expired or discoloured kit |
| Process temperature | Store within the range printed on the label; do not freeze |
| Process connection | Bottle and cap sized for the analyser's reagent pump |
| Output signal | Not applicable - the reagent is consumed by the analyser |
| Power supply | Not applicable - consumable |
| Wetted materials | Reagent solution in a sealed plastic bottle with a dispensing cap |
| Diagnostics | Analyser reports reagent level and an expired-reagent condition |
| Certifications | Safety data sheet supplied; reagents are classified for transport and storage per the label |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer