Rosemount SPG Smart Pressure Gauge
Purchase options
From$412.73
Select optionConfigurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Smart pressure gauge with a 4.5 in dial and +/-0.5 percent of span to ASME B40.1 Grade 2A, from 15 inH2O to 10,000 psi, with a 10 year installed life.
Key features
- Smart pressure gauge with a 4.5 in (114 mm) dial, nominal accuracy +/-0.5 percent of span aligned with ASME B40.1 Grade 2A
- Scale ranges from 15 inH2O (37.3 mbar) to 10,000 psi (689.5 bar) across gauge, absolute, vacuum, compound and mirror measurement types
- Digital measurement with no Bourdon tube or movement to fatigue: up to a 10 year installed life, and a reading that does not drift silently
- Option P5 is required for any specified range above 4,001 psi (275.9 bar), covering the 4,001 to 10,000 psi band
- Option L provides local HART terminals for LOCAL CONFIGURATION only, not a continuous transmitter output to a control system
- Naming a gauge accuracy class makes the substitution from a mechanical gauge a decision rather than an inference
Key specifications
- Accuracy
- Nominal +/-0.5 percent of span, aligned with ASME B40.1 Grade 2A. Stating the gauge grade alongside the percentage is what makes the substitution from a mechanical gauge a decision rather than an inference
- Output signal
- Local indication on a 4.5 in (114 mm) dial. Option L provides local HART terminals for local configuration only - not a continuous transmitter output to a control system
- Diagnostics
- A digital measurement replaces the failure mode a mechanical gauge cannot report: a fatigued Bourdon tube or a stiffened movement leaves the needle pointing at a new, wrong and entirely plausible reading. Up to a 10 year installed life follows from having no moving parts to wear
- Pressure range
- Scale ranges from 15 inH2O (37.3 mbar) to 10,000 psi (689.5 bar). Option P5 is required for any specified range above 4,001 psi (275.9 bar), covering the 4,001 to 10,000 psi band
- Variants
- Dial size 45 (4.5 in / 114.3 mm). Measurement types gauge, absolute, vacuum, compound and mirror. Engineering units psi, bar, mBar and percent of range, with psi, bar and inH2O available as decimal scale options. Option P5 for 4,001 to 10,000 psi; option L for local HART terminals
- Application
- Replacing mechanical gauges where the reading is used rather than merely looked at: pump discharge, filter differential, regulator outlets and vessel pressure on skids where a wrong reading has consequences but a full transmitter was never justified
Stated in the language of the instrument it replaces
The Rosemount SPG is a smart pressure gauge: a 4.5 in (114 mm) dial with a digital measurement behind it, scale ranges from 15 inH2O (37.3 mbar) to 10,000 psi (689.5 bar), and a nominal accuracy of ±0.5 percent of span — which aligns with ASME B40.1 Grade 2A.
That last clause is the most important sentence on the datasheet, and it is the one most easily skipped.
Why the standard matters more than the percentage
A pressure gauge is bought by people who think in gauge grades. Grade 2A is a recognised accuracy class in ASME B40.1 — the standard that defines how mechanical pressure gauges are specified, marked and tested. By stating conformance alongside its own percentage, the product answers the question a gauge buyer actually asks: what would I have specified if this were a mechanical gauge, and does this meet it?
A digital instrument that quoted "0.5 percent" without naming a class would leave that buyer comparing a digital specification against a mechanical one, which is not a comparison at all — the test conditions, the reference temperature and the definition of span differ between standards. Naming Grade 2A makes the substitution a decision rather than an inference.
A gauge that can say something is wrong
The datasheet's argument for the product is worth quoting in substance: mechanical parts are what inhibit a traditional gauge from reporting or displaying the correct pressure. That is a description of a failure mode with no alarm. A Bourdon tube fatigues, a movement loses calibration, a linkage stiffens — and a mechanical gauge simply keeps pointing at its new, wrong, plausible reading. Nobody knows until somebody compares it with a second instrument, which on most plants happens rarely or never.
The up-to-10-year installed life is the counterpart claim: the failure mechanism being avoided is wear in moving parts, so a design without them has a life measured in years rather than in cycles of drift nobody observes.
One family, vacuum to 10,000 psi
Measurement types are gauge, absolute, vacuum, compound and mirror, across a scale range that starts at 15 inches of water column and ends at 10,000 psi. The low end is the interesting one: 15 inH2O is a measurement that a mechanical gauge of that accuracy class cannot resolve well, and at that scale a digital sensor is doing real work rather than merely matching a needle.
One ordering rule has to be respected: option P5 is required with any specified range above 4,001 psi (275.9 bar), covering the 4,001 to 10,000 psi band. A high-range order without it is not a valid configuration, and the rule is the kind that gets missed when a model code is assembled from a table rather than from a configurator.
Local HART is local
Option L provides HART terminals for local configuration only. That wording is precise and worth respecting: the terminals exist so a technician can configure the gauge with a handheld at the point of installation, not so the gauge can be polled continuously by a control system as a transmitter. Anyone expecting to bring it into a host as a HART device has misread the option, and the difference is visible in the product name — a gauge with configuration terminals, not a transmitter with a dial.
Where it fits
Replacing mechanical gauges at points where the reading is used rather than merely looked at: pump discharge, filter differential, regulator outlets and vessel pressure on skids where a wrong gauge reading has consequences but a full transmitter was never justified. The 4.5 inch face is a field-visibility decision, and on a unit where operators walk past the gauge every shift, that is the whole point — a gauge nobody can read from the walkway is a gauge nobody reads.
Manufacturer reference: Rosemount SPG Smart Pressure Gauge Product Data Sheet 00813-0100-4145 for accuracy class, scale ranges, measurement types and ordering information.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Nominal +/-0.5 percent of span, aligned with ASME B40.1 Grade 2A. Stating the gauge grade alongside the percentage is what makes the substitution from a mechanical gauge a decision rather than an inference |
| Output signal | Local indication on a 4.5 in (114 mm) dial. Option L provides local HART terminals for local configuration only - not a continuous transmitter output to a control system |
| Diagnostics | A digital measurement replaces the failure mode a mechanical gauge cannot report: a fatigued Bourdon tube or a stiffened movement leaves the needle pointing at a new, wrong and entirely plausible reading. Up to a 10 year installed life follows from having no moving parts to wear |
| Pressure range | Scale ranges from 15 inH2O (37.3 mbar) to 10,000 psi (689.5 bar). Option P5 is required for any specified range above 4,001 psi (275.9 bar), covering the 4,001 to 10,000 psi band |
| Variants | Dial size 45 (4.5 in / 114.3 mm). Measurement types gauge, absolute, vacuum, compound and mirror. Engineering units psi, bar, mBar and percent of range, with psi, bar and inH2O available as decimal scale options. Option P5 for 4,001 to 10,000 psi; option L for local HART terminals |
| Application | Replacing mechanical gauges where the reading is used rather than merely looked at: pump discharge, filter differential, regulator outlets and vessel pressure on skids where a wrong reading has consequences but a full transmitter was never justified |
| Mounting | Bottom process connection with a hex nut and threaded fitting, mounted directly on the pipe or pressure port. The 4.5 in face is a field-visibility decision for gauges operators walk past every shift |
| Operating temperature (°C) | Set by the process connection and the gauge construction, with the dial and electronics protected by the enclosure and lens |
Accessories and related items