Rosemount Model T1056 Clarity II Turbidimeter
Purchase options
From$1,346.16
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Low-range turbidimeter for drinking water and clean process water, with ninety-degree scattered light optics, a debubbling sample path and HART output.
Key features
- Low-range turbidity measurement for drinking water and clean process water
- Ninety-degree scattered light optics in an enclosed sample chamber
- Debubbling sample path ahead of the measuring cell
- Calibration against formazin or stabilised standards
- Diagnostics for lamp, window fouling and sample flow
- 4-20 mA output with HART and relay contacts
Key specifications
- Measurement principle
- Ninety-degree scattered light nephelometry
- Accuracy
- ±2% of reading or ±0.02 NTU, whichever is greater, in the low range
- Process temperature
- 0 to 50 C (32 to 122 F) sample temperature
- Process connection
- Sample inlet and drain on the debubbling chamber
- Enclosure rating
- NEMA 4X transmitter enclosure with a separate sample chamber
- Output signal
- 4-20 mA output with HART digital signal, plus relay contacts
What the T1056 Clarity II is
A turbidimeter built for the low ranges that drinking water and clean process water are judged on. Turbidity is a scattered-light measurement, and below about 1 NTU the design of the sample chamber matters more than the electronics — stray light, bubbles and window fouling each produce a reading that is stable and wrong.
The optical arrangement
Light passes through the sample and the scattered component is measured at ninety degrees, with the optical path enclosed to keep room light out. The sample flows through a debubbling chamber before the measuring cell, because an air bubble crossing the beam reads as a turbidity spike.
What it is used for
Filtered drinking water at the plant outlet, filter-to-waste decisions, condensate returns in power plants, clarifier effluent and final discharge. Each of those is a low-turbidity application where the instrument has to hold a repeatable reading, not just respond to a big change.
Calibration and records
Calibrated against formazin or a stabilised standard, with the calibration held in the transmitter. Diagnostics flag lamp failure, a dirty window and a blocked sample flow rather than letting the reading drift quietly.
Outputs
4-20 mA output with HART digital communication, plus relay contacts for alarm and for a filter-backwash decision. The transmitter mounts locally with the sample chamber on a panel.
Manufacturer reference: Emerson T1056 Clarity II product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Ninety-degree scattered light nephelometry |
| Accuracy | ±2% of reading or ±0.02 NTU, whichever is greater, in the low range |
| Process temperature | 0 to 50 C (32 to 122 F) sample temperature |
| Process connection | Sample inlet and drain on the debubbling chamber |
| Enclosure rating | NEMA 4X transmitter enclosure with a separate sample chamber |
| Output signal | 4-20 mA output with HART digital signal, plus relay contacts |
| Power supply | 85-265 V AC, four-wire |
| Wetted materials | Glass optical cell, PVC and PTFE sample tubing |
| Diagnostics | Lamp failure, window fouling and low sample flow flagged by the transmitter |
| Certifications | CE; enclosure rated for indoor sample service |