Rosemount TCL Total Chlorine Analyzer
Purchase options
From$2,121.37
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Reagent-based total chlorine analyser that measures free and combined chlorine photometrically, with ranges up to 10 ppm and a sample path built for seawater and high-chloride water.
Key features
- Reagent-based total chlorine measurement, free plus combined chlorine
- Photometric detection in a controlled flow system
- Ranges up to 10 ppm chlorine
- Handles seawater and high-chloride samples
- Isolated 4-20 mA outputs with HART, Profibus option
- Relay contacts for alarms and reagent level
Key specifications
- Measurement principle
- Reagent reaction with photometric detection in a continuous flow cell
- Accuracy
- ±5% of reading or ±0.05 ppm, whichever is greater, after calibration with a reference method
- Process temperature
- 5 to 40 C (41 to 104 F) sample temperature
- Process connection
- Sample inlet, drain and reagent connections on the analyser panel
- Enclosure rating
- NEMA 4X analyser enclosure for indoor mounting
- Output signal
- Isolated 4-20 mA outputs with HART digital signal; Profibus DP option
What the TCL analyzer is
A complete total chlorine measuring system built around reagent chemistry rather than a membrane sensor. Total chlorine is the sum of free chlorine and the chloramines bound up with ammonia, and only a reagent method sees both halves — which is why a plant that must report total chlorine uses a system like this rather than an amperometric sensor.
How the measurement works
The sample is mixed with reagent in a controlled flow, the reaction develops colour, and a photometric cell reads the absorbance. Reagent dosing, mixing, reaction time and the optical path are all inside the analyser, so the result is a number rather than an operator technique.
Built for difficult samples
The system handles seawater and other high-chloride samples, where a colorimetric method with a different reagent set would be blinded by the background. Ranges up to 10 ppm chlorine are available, and the analyser is set up for continuous sample flow with automatic reagent metering.
Outputs and records
Isolated 4-20 mA outputs with HART digital communication, optional Profibus, and relay contacts for alarms and reagent-level warnings. The analyser logs the measurement history that a regulatory report is built from.
Where it fits
Municipal drinking water and wastewater disinfection, industrial cooling water, food and beverage plants and seawater-based systems — anywhere total chlorine, not free chlorine, is the compliance number.
Manufacturer reference: Emerson TCL analyzer product data sheet.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Reagent reaction with photometric detection in a continuous flow cell |
| Accuracy | ±5% of reading or ±0.05 ppm, whichever is greater, after calibration with a reference method |
| Process temperature | 5 to 40 C (41 to 104 F) sample temperature |
| Process connection | Sample inlet, drain and reagent connections on the analyser panel |
| Enclosure rating | NEMA 4X analyser enclosure for indoor mounting |
| Output signal | Isolated 4-20 mA outputs with HART digital signal; Profibus DP option |
| Power supply | 85-265 V AC, four-wire |
| Wetted materials | PVC and PTFE tubing, glass flow cell and reagent-resistant fittings |
| Diagnostics | Reagent level, flow and optical cell condition monitored, with relay outputs for each fault |
| Certifications | CE; system approval follows the analyser and transmitter used |