Rosemount TUpH 396 / 396VP pH/ORP Sensor
Purchase options
From$287.31
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Fixed-mount TUpH pH/ORP sensor in a 316 stainless steel body with a hemi or flat ACCUGLASS bulb, mounted through a 1 in NPT process connector.
Key features
- Fixed-mount TUpH pH/ORP sensor, pH 0-14 or ORP -1500 to +1500 mV
- Hemi or flat ACCUGLASS bulb - the flat bulb resists coating in dirty service
- 316 stainless steel body with polypropylene and EPDM wetted parts
- Mounts through a 1 in NPT process connector 23166-00 or 23166-01, sold separately
- 0 to 100 °C; 150 psig with a hemi bulb, 100 psig with a flat bulb
- 15 ft coaxial cable, or Variopol connector with cable 24281-XX on the 396VP
The fixed-mount TUpH pH sensor
A screw-in pH or ORP electrode in a 316 stainless body, specified with a flat or hemi ACCUGLASS bulb and a reference junction built to survive dirty service. It is the version that goes into a tee or a submersion fitting and stays there — where the process does not need the sensor pulled out at line pressure, and where the simpler installation is worth having.
Why the flat bulb exists
A standard pH bulb is a glass hemisphere, and a coating plant will blind it: solids bridge across the dome and the reading drifts as the junction plugs behind it. The flat bulb sits nearly flush with the body, so the flow wipes it instead of building a deposit on it — the self-cleaning behaviour that matters more in a pulp line than any laboratory specification. Choose hemi where the measurement is clean and accuracy is the priority; flat where the sensor would otherwise be cleaned weekly.
Why the body is stainless here
The 396 body is 316 stainless with polypropylene and EPDM wetted parts — the standard construction for water, chemical and food-adjacent service. Where the process attacks stainless, the titanium 396P is the same sensor in a different body. Ordering between them is a chemistry decision, and the process connection is separate in both cases.
The connection you have to order
There is no thread on the sensor itself. It mounts through a 1 in NPT metal process connector — 23166-00 in 316 SST or 23166-01 in titanium — which is sold separately and is what holds the sensor at the insertion depth you set. Leaving it off the order is the most common mistake with this family; the sensor cannot be installed without it.
Pressure, temperature and cable
Rated 0 to 100 °C, 150 psig with a hemi bulb and 100 psig with a flat bulb. The signal is high-impedance, so the cable is part of the measurement: 15 ft coaxial with BNC as standard, or the 396VP with a Variopol connector and cable 24281-XX in the length required. Minimum conductivity for a stable pH reading is 100 µS/cm.
Where it fits
Chemical and industrial pH/ORP points, water and wastewater, food-adjacent processes and any installation where a fixed sensor in a tee or a submersion fitting is enough — with 396VP where a quick-disconnect suits maintenance.
Manufacturer reference: Rosemount 396/396VP/396P/396PVP/396R/396RVP TUpH pH/ORP Sensors Product Data Sheet, LIQ-PDS-396, table 7.