Configure la variante exacta Elija las opciones a continuación. El número de pieza, el precio y la validez de la configuración se actualizan a medida que selecciona, confirmados por nuestro sistema.
ApprovalObligatorio Non-hazardous area AA Opción predeterminada +0.00 USD ATEX II3G Ex nA IIC T6 B2 +27.97 USD ATEX II1G Ex ia IIC T6, II3D B4 +22.68 USD ATEX II3G Ex nA IIC T6, II3D B5 +30.14 USD ATEX II2G Ex d T6, II2D Ex tb IIIC B6 +28.47 USD ATEX II1G Ex ia IIC T4/T5/T6 BA +29.93 USD ATEX II3G Ex ic IIC T6 BC +22.45 USD ATEX II2D Ex tb IIIC Db BF +24.62 USD ATEX II3D Ex tc IIIC Dc BG +9.91 USD CSA IS, NI I / 1+2/A-D C1 +26.51 USD CSA XP, NI, DIP I, II, III/1+2/A-G C3 +25.14 USD FM IS,NI I / 1+2/A-D F1 +26.23 USD FM XP, NI, DIP I, II, III/1+2/A-G F3 +22.42 USD ATEX IECEx II1G Ex ia IIC T6 Ga 8A +31.08 USD FM+CSA IS, NI I/1+2/A-D 8C +24.64 USD EAC Ex ia IIC T6 Ga GA +28.75 USD EAC Ex d IIC T6 Gb GD +28.67 USD Non-hazardous area + EAC marking GR +0.00 USD IECEx Ex d T6 Gb, Ex tb IIIC Db I6 +29.68 USD IECEx Ex ia IIC T4/T5/T6 IA +24.99 USD IECEx Ex tb IIIC Db IF +24.51 USD NEPSI Ex ia IIC T6 Ga NA +28.60 USD NEPSI Ex nA IIC T6 Gc NN +29.15 USD
Electrical ConnectionObligatorio Spring terminals, housing form B, DIN EN 50446 1 Opción predeterminada +0.00 USD Screw terminals, housing form B, DIN EN 50446 2 +0.00 USD Screw terminals, housing for DIN rail mounting 17.5mm 3 +6.06 USD
Field HousingObligatorio Without C Opción predeterminada +0.00 USD W/o, mounting set DIN standard A +0.00 USD W/o, mounting set US - M4 screws B +0.00 USD TA30H, Alu, 2x M20x1.5, w/o display window, explosion-proof enclosure D +53.57 USD TA30H, Alu, 2x M20x1.5, glass display window, explosion-proof enclosure E +58.76 USD TA30H, Alu, 2x 1/2NPT, w/o display window, explosion-proof enclosure F +51.19 USD TA30H, Alu, 2x 1/2NPT, glass display window, explosion-proof enclosure G +69.85 USD TA30A, 2x M20x1.5, w/o display window, universal housing with hinged cover H +26.34 USD TA30A, 2x M20x1.5, glass display window, universal housing w/ hinged cover I +30.31 USD TA30A, 2x 1/2NPT, w/o display window, universal housing with hinged cover J +24.29 USD TA30A, 2x 1/2NPT, glass display window, universal housing with hinged cover K +33.26 USD TA30D, 2x M20x1.5, universal housing with hinged cover high L +36.05 USD TA30D, 2x 1/2NPT, universal housing with hinged cover high M +28.80 USD TA30H, 316L, 2x 1/2NPT, w/o display window, explosion-proof enclosure P +198.01 USD TA30H, 316L, 2x 1/2NPT, glass display window, explosion-proof enclosure Q +194.23 USD
Configuration Universal InputObligatorio Ch1: RTD 2-wire, Ch2: inactive A1 Opción predeterminada +0.00 USD Ch1: RTD 2-wire, Ch2: RTD 2-wire A2 +0.00 USD Ch1: RTD 2-wire, Ch2: RTD 3-wire A3 +0.00 USD Ch1: RTD 2-wire, Ch2: TC A4 +0.00 USD Ch1: RTD 3-wire, Ch2: inactive B1 +0.00 USD Ch1: RTD 3-wire, Ch2: RTD 2-wire B2 +0.00 USD Ch1: RTD 3-wire, Ch2: RTD 3-wire B3 +0.00 USD Ch1: RTD 3-wire, Ch2: TC B4 +0.00 USD Ch1: RTD 4-wire, Ch2: inactive C1 +0.00 USD Ch1: RTD 4-wire, Ch2: TC C2 +0.00 USD Ch1: TC, Ch2: inactive D1 +0.00 USD Ch1: TC, Ch2: TC D2 +0.00 USD
Sensor Type Input 1Obligatorio Pt100, -200 to 850°C, min. span 10K, IEC60751 (a = 0.00385) A1 Opción predeterminada +0.00 USD Pt200, -200 to 850°C, min. span 10K, IEC60751 (a = 0.00385) A2 +0.00 USD Pt500, -200 to 500°C, min. span 10K IEC60751 (a = 0.00385) A3 +0.00 USD Pt1000, -200 to 250°C, min. span 10K IEC60751 (a = 0.00385) A4 +0.00 USD Pt100, -200 to 510°C, min. span 10K, JIS C1604-81 (a = 0.003916) B1 +0.00 USD Ni100, -60 to 250°C, min. span 10K DIN 43760 (a = 0.006180) C1 +0.00 USD Ni120, -60 to 250°C, min. span 10K DIN 43760 (a = 0,006180) C2 +0.00 USD Pt50, -185 to 1100°C, min. span 10K, GOST 6651-94 (a = 0.003910) D1 +0.00 USD Pt100, -200 to 850°C, min. span 10K GOST 6651-94 (a = 0.003910) D2 +0.00 USD Ni100, -60 to 180°C, min. span 10K GOST 6651-94 (a = 0.006170) D3 +0.00 USD Ni120, -60 to 180°C, min. span 10K GOST 6651-94 (a = 0.006170) D4 +0.00 USD Cu50, -175 to 200°C, min. span 10K, GOST 6651-94 (a = 0.004280) D5 +0.00 USD Cu50, -50 to 200°C, min. span 10K, OIML R84:2003/GOST 6651-94 (a=0.004260) E1 +0.00 USD Cu100, -175 to 200°C, min. span 10K, GOST 6651-2009, (a = 0,004280) E2 +0.00 USD Resist. transmitter 10 to 400 Ohm, min. span 10 Ohm F1 +0.00 USD Resist. transmitter 10 to 2000 Ohm, min. span 10 Ohm F2 +0.00 USD
Sensor Type Input 2Obligatorio Inactive AA Opción predeterminada +0.00 USD
Input InterconnectionObligatorio PV = CH1; CH2 inactive A1 Opción predeterminada +0.00 USD
DisplayObligatorio Without WITHOUT Opción predeterminada +0.00 USD DIP-switch, plug-able E1 +36.79 USD
CalibrationObligatorio Without WITHOUT Opción predeterminada +0.00 USD Works calib. certificate 6-point, fixed F1 +20.96 USD Works calib. certificate 6-point, free selectable F2 +41.29 USD
ServiceObligatorio Without WITHOUT Opción predeterminada +0.00 USD Configuration: alarm limit low H1 +5.04 USD Configuration: alarm limit high H2 +4.58 USD
Additional ApprovalObligatorio Without WITHOUT Opción predeterminada +0.00 USD UL listed LU +0.00 USD SIL conformity LA +38.01 USD GL marine approval LE +9.68 USD LR marine approval LG +9.44 USD BV marine approval LH +8.72 USD ABS marine approval LF +9.63 USD
Accessory MountedObligatorio Without WITHOUT Opción predeterminada +0.00 USD
Accessory EnclosedObligatorio Without WITHOUT Opción predeterminada +0.00 USD
Cable Gland, Temperature Range and Protection TypeObligatorio Without WITHOUT Opción predeterminada +0.00 USD
Firmware VersionObligatorio Without WITHOUT Opción predeterminada +0.00 USD 01.01.zz, HART 7, DevRev02 78 +0.00 USD 01.02.zz, HART 7, DevRev03 77 +0.00 USD
MarkingObligatorio Without WITHOUT Opción predeterminada +0.00 USD Tagging (TAG), metal label Z1 +9.38 USD Tagging (TAG), measuring point Z2 +9.13 USD Commissioning label, paper Z3 +10.99 USD Tagging (TAG), Fieldbus Z4 +9.77 USD Tagging (TAG), by customer Z6 +11.61 USD Tagging (TAG), descriptor configuration 16 characters ZA +10.62 USD