Resumen

Transmisor de temperatura WirelessHART con entradas universales y tecnología X-well, que calcula la temperatura de proceso sin termopozo.

Especificaciones principales

Exactitud
Pt100 +/-0.225 C (+/-0.405 F) from -200 to 850 C; Rosemount X-well Pt100 +/-0.29 C (+/-0.52 F) over -50 to 300 C. Transmitter-sensor matching with Callendar-Van Dusen coefficients is quoted as a 75 percent accuracy improvement by removing the sensor's interchangeability error
Señal de salida
IEC-approved WirelessHART (IEC 62591) at 2.4 GHz DSSS with user-configurable update rate; optional external antenna (WK1) and extended range antenna options (WM1/WM2)
Diagnósticos
Open and short sensor diagnostics detect sensor loop faults before the reading becomes plausible nonsense; user-centric device dashboards expose process health. Power module is intrinsically safe, field replaceable with keyed connections, rated 10 years at a one-minute update rate, and ships separately
Rango de presión
Not applicable to the transmitter itself - it mounts on the sensor or pipe. With X-well there is no penetration, so the pipe's pressure boundary is unchanged
Variantes
Single sensor input with universal options: 2-, 3- and 4-wire RTD (Pt100, Pt100 GOST, Cu50), thermocouple, mV and ohms. Dual-compartment housing in aluminium (D) or stainless steel (E). Assemble-to-sensor option (XA) for a complete point solution
Aplicación
Temperature points on existing lines where cutting in a thermowell is not worth a shutdown, hygienic piping where a well is a cleaning liability, and remote measurements where cable cost exceeds the instrument cost