Rosemount 1199 CTW Chemical Tee Seal
Purchase options
From$626.96
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Chemical tee diaphragm seal with an eight-bolt pattern for wedge flow elements and chemical tees: 300 psi MWP, 316L or Alloy C-276, NACE option.
Key features
- Chemical tee diaphragm seal with an eight-bolt connection pattern that bolts into a chemical tee or onto a wedge flow primary element
- Maximum working pressure 300 psi (21 bar), the only rating offered - the pressure boundary is the tee, not a standard flange
- Non-industry-standard flange designation, ordered by connection pattern rather than by flange class
- Wetted materials 316L stainless or Alloy C-276, with the upper housing in the matching alloy on the C-276 option
- Low side drain/vent valve (code FV) is required when the seal is assembled to a DP transmitter using connection option code A
- NACE MR0175 / ISO 15156 and MR0103 certificate option for sour service, plus 3-year and 5-year limited warranty options
Key specifications
- Accuracy
- Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and DP flow accuracy is set by the primary element, the transmitter and the fill fluid
- Output signal
- Hydraulic: process pressure deflects the diaphragm and displaces fill fluid to the transmitter. A low side drain/vent valve (code FV) is required when the seal is assembled to a DP transmitter using connection option code A
- Diagnostics
- Non-industry-standard flange means there is no adapter that rescues a wrong pattern - the part either fits the tee or it does not. The FV valve is a required option, not an accessory, wherever a DP transmitter is attached through connection code A
- Pressure range
- Maximum working pressure 300 psi (21 bar), the only rating offered, with a non-industry-standard flange designation. The pressure boundary is the tee and its connection pattern, not a standard flange chosen from a class table
- Variants
- Wetted materials 316L stainless or Alloy C-276, with the upper housing in the matching alloy on the C-276 option; lower housing not supplied; 3-year (WR3) or 5-year (WR5) limited warranty; NACE MR0175 / ISO 15156 and MR0103 certificate option for sour service
- Application
- Chemical dosing and sampling lines, water treatment chemical feed, and wedge flow installations where the tee is already in the pipe and the pressure tap needs a diaphragm to keep the transmitter isolated from a plugging or corrosive fluid
A seal that goes into a tee that is already there
The Rosemount 1199 CTW is a chemical tee seal: a diaphragm seal with an eight-bolt connection pattern designed to bolt into a chemical tee or onto a wedge flow primary element. It is not a general-purpose pressure seal — it is the part that turns an existing tee into a diaphragm-protected pressure tap, which is why Emerson lists it as a retro-fit rather than a seal you select for a new line.
The eight-bolt pattern is the specification
Most of the 1199 family is ordered by flange standard and class, because most of it bolts to a pipe flange. The CTW is ordered by connection pattern instead: eight bolts on a chemical tee. That means the selection question is not "what class is the line" but "what tee is installed, and what is its bolt pattern". Getting that wrong is not a matter of derating — the part simply does not fit, and there is no adapter that makes it fit.
Three hundred psi, and why that is not a limitation to argue with
The maximum working pressure of the CTW is 300 psi (21 bar) — the only rating offered, with a non-industry-standard flange designation. That is low for a seal with eight bolts, and it is worth understanding why: the pressure boundary here is the tee and its connection, not a standard flange the buyer picks from a table. A chemical tee in a dosing or sampling line is a low-pressure component by design, so the seal is built to match it. Anyone specifying this seal for a high-pressure line has misread what it bolts to.
The materials, and the valve that is not optional
Wetted materials are 316L stainless or Alloy C-276, with the upper housing in the matching alloy on the C-276 option. Two options are worth reading closely. The low side drain/vent valve (code FV) is listed as required when the seal is assembled to a transmitter with a differential pressure measurement type using connection option code A — that is not an accessory, it is part of making the DP measurement fillable and drainable. And the NACE certificate confirms the materials meet NACE MR0175/ISO 15156 for sour oil field production and MR0103 for sour refining, with the usual caveat that environmental limits apply to certain materials.
Where it earns its place
Chemical dosing and sampling lines, water treatment chemical feed, and any wedge flow installation where the tee is already in the pipe and the pressure tap needs a diaphragm. The value is in not cutting the line: the tee stays, the seal goes in, and the transmitter is isolated from a fluid that would otherwise plug or corrode its way into the impulse connections. In a dosing line, that is often the difference between a measurement that survives the chemical and one that has to be purged weekly.
What it is not
It is not a replacement for a flanged seal on a standard pipe flange, and it is not a high-pressure part. It is a specific answer to a specific fitting — and the fact that Emerson offers a three- and five-year limited warranty on it says more about how the part is used than any marketing line would: it is expected to sit in a chemical line and be forgotten about.
Manufacturer reference: Rosemount 1199 Diaphragm Seal Systems Product Data Sheet 00813-0100-4016, CTW chemical tee seal model components, and the 1199 quick start guide.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and DP flow accuracy is set by the primary element, the transmitter and the fill fluid |
| Output signal | Hydraulic: process pressure deflects the diaphragm and displaces fill fluid to the transmitter. A low side drain/vent valve (code FV) is required when the seal is assembled to a DP transmitter using connection option code A |
| Diagnostics | Non-industry-standard flange means there is no adapter that rescues a wrong pattern - the part either fits the tee or it does not. The FV valve is a required option, not an accessory, wherever a DP transmitter is attached through connection code A |
| Pressure range | Maximum working pressure 300 psi (21 bar), the only rating offered, with a non-industry-standard flange designation. The pressure boundary is the tee and its connection pattern, not a standard flange chosen from a class table |
| Variants | Wetted materials 316L stainless or Alloy C-276, with the upper housing in the matching alloy on the C-276 option; lower housing not supplied; 3-year (WR3) or 5-year (WR5) limited warranty; NACE MR0175 / ISO 15156 and MR0103 certificate option for sour service |
| Application | Chemical dosing and sampling lines, water treatment chemical feed, and wedge flow installations where the tee is already in the pipe and the pressure tap needs a diaphragm to keep the transmitter isolated from a plugging or corrosive fluid |
| Mounting | Eight-bolt pattern that bolts into a chemical tee or onto a wedge flow primary element. It is a retro-fit part: the selection question is which tee is installed and what its bolt pattern is, not what flange class the line carries |
| Operating temperature (°C) | Set by the fill fluid and the diaphragm material; the seal sits in a low pressure chemical tee, so the fluid temperature and the gasket material at the tee are usually the binding limits |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer