Rosemount 1199 FUW & FVW Flush Flanged Seals
Purchase options
From$921.40
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Flush flanged diaphragm seals with EN 1092-1 tongue or groove faces for DN 25 to DN 80 at PN 40, in European, Russian and Chinese flange standards.
Key features
- Flush flanged diaphragm seals with a tongue (FVW, EN 1092-1 type C) or groove (FUW, type D) process flange face
- Sizes DN 25, DN 50 and DN 80 at PN 40, to EN 1092-1, GOST 33259-15 or Chinese HG20592
- A tongue seal mates with a groove flange and a groove seal with a tongue flange - the two are ordered as a pair
- The interlocking joint confines the gasket in a cavity, so it cannot creep or blow out on thermal cycling service
- Diaphragm in 316L, Alloy C-276 or tantalum; 316L upper housing, 316 stainless flange
- No gasket is supplied with the seal - the gasket has to be ordered separately in the material the fluid requires
Key specifications
- Accuracy
- Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and loop accuracy is set by the transmitter, the fill fluid and the capillary run
- Output signal
- Hydraulic: process pressure deflects the flush diaphragm and displaces fill fluid to the transmitter, which is ranged for the seal's fill fluid and temperature
- Diagnostics
- The confined gasket cannot walk or blow out the way a flat gasket between raised faces can, but the seal arrives without a gasket, so the joint cannot be made until the correct gasket form and material are on site
- Pressure range
- PN 40 for DN 25, DN 50 and DN 80 to EN 1092-1; also available to GOST 33259-15 and the Chinese HG20592 standard based on EN 1092-1
- Variants
- FUW is EN 1092-1 type D (groove) and FVW is type C (tongue). Diaphragm 316L or tantalum only with the one-piece design, Alloy C-276 only with the two-piece design; 316L upper housing and 316 stainless flange; no flushing connection and no gasket supplied
- Application
- European-standard process lines where a gasket that creeps is unacceptable: thermal cycling service, vertical runs, high viscosity or crystallising media, and chemical or hygienic lines whose flange form is fixed by plant standard
Tongue and groove: two seals that only work as a pair
The Rosemount 1199 FUW and FVW are flush flanged diaphragm seals with a tongue or groove process flange face — EN 1092-1 type C (tongue) and type D (groove) — for DN 25, DN 50 and DN 80 lines in European, Russian and Chinese flange standards. They are two products because the joint they make is a pair: one face carries a raised ring, the other a matching recess, and the two interlock.
Why a tongue-and-groove joint exists
A flat gasket between two raised faces relies on friction and bolt load to stay where it was put. On a line that cycles in temperature, that gasket creeps outward; on a line with vibration, it walks. A tongue-and-groove joint removes that failure mode entirely: the tongue enters the groove, the gasket sits confined in the resulting cavity, and it has nowhere to go. The joint also self-centres, which matters on a vertical line where a gasket that shifts during assembly is a leak waiting to be commissioned.
Which one you order depends on what is already on the pipe
A tongue seal faces a groove flange; a groove seal faces a tongue flange. That is the whole rule, and getting it backwards means the seal does not seat. The ordering codes make the distinction explicit — FUW is EN 1092-1 type D (groove) and FVW is type C (tongue) — so the specification question is not "which is better" but "what is bolted to the pipe". A plant built to EN 1092-1 will usually have one of the two, and the seal is ordered to match it rather than the other way around.
The gasket is not in the box
Emerson states plainly for these seals that no gasket is supplied. That is worth reading twice, because it is the one line item that stops a commissioning: the seal arrives, the flange is open, and the joint cannot be made until a gasket of the right form and material is on site. It also means the gasket material is the buyer's decision, which is the correct place for it — the gasket has to suit the fluid, and the seal does not know what the fluid is.
The envelope
Sizes are DN 25, DN 50 and DN 80 at PN 40, to EN 1092-1, GOST 33259-15 or the Chinese HG20592 standard. Diaphragm options are 316L stainless, Alloy C-276 and tantalum, with a 316L upper housing and a 316 stainless flange. Two constraints in the model code are worth noting: the 316L and tantalum diaphragms are available only with the one-piece design, while Alloy C-276 is available only with the two-piece design. A specification that fixes both the diaphragm material and the construction style without checking that pairing will end up at a non-orderable combination.
Where it fits
European-standard process lines carrying fluids where a gasket that creeps is unacceptable: thermal cycling service, vertical runs, high-viscosity or crystallising media, and hygienic or chemical lines built to EN 1092-1 where the flange form is already fixed by plant standard. The flush diaphragm means no pocket behind the joint, so the same seal that solves the gasket problem also solves the fouling problem.
Manufacturer reference: Rosemount 1199 Diaphragm Seal Systems Product Data Sheet 00813-0100-4016, FUW and FVW flush flanged type model components, and the 1199 quick start guide.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and loop accuracy is set by the transmitter, the fill fluid and the capillary run |
| Output signal | Hydraulic: process pressure deflects the flush diaphragm and displaces fill fluid to the transmitter, which is ranged for the seal's fill fluid and temperature |
| Diagnostics | The confined gasket cannot walk or blow out the way a flat gasket between raised faces can, but the seal arrives without a gasket, so the joint cannot be made until the correct gasket form and material are on site |
| Pressure range | PN 40 for DN 25, DN 50 and DN 80 to EN 1092-1; also available to GOST 33259-15 and the Chinese HG20592 standard based on EN 1092-1 |
| Variants | FUW is EN 1092-1 type D (groove) and FVW is type C (tongue). Diaphragm 316L or tantalum only with the one-piece design, Alloy C-276 only with the two-piece design; 316L upper housing and 316 stainless flange; no flushing connection and no gasket supplied |
| Application | European-standard process lines where a gasket that creeps is unacceptable: thermal cycling service, vertical runs, high viscosity or crystallising media, and chemical or hygienic lines whose flange form is fixed by plant standard |
| Mounting | A tongue seal faces a groove flange and a groove seal faces a tongue flange - the pair interlocks, confines the gasket in the resulting cavity and self-centres the joint, so the seal must be ordered to match what is already bolted to the pipe |
| Operating temperature (°C) | Set by the fill fluid and the diaphragm material. The interlocking joint itself is chosen for service where a confined gasket is needed, but the seal's published limits remain those of its fill fluid |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer