Rosemount 1199 RFW Remote Flanged Seal
No product images are published for this product yet.
Purchase options
From$628.25
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Remote flanged diaphragm seal with a flush diaphragm on a raised-face flange: 1/2 in. to 1-1/2 in., Class 150 to 2500, for small bore lines.
Key features
- Remote flanged diaphragm seal with the diaphragm flush against a raised-face process flange, so no pocket forms between process and element
- Sizes 1/2 in. to 1-1/2 in. (DN 10 to DN 40) in ASME B16.5 Class 150 to 2500 and EN 1092-1 PN 6 to PN 160
- Flange standards ASME B16.5, EN 1092-1, GOST 33259-15, JIS B2238 and Chinese HG20615 / HG20592
- Diaphragm in 316L, Alloy C-276, tantalum, Alloy 400, Nickel 201, Alloy 20, Alloy 600, Alloy B, titanium Gr. 4, Alloy C-22, duplex 2205/2507 or Zirconium 702
- Remote mounting puts the transmitter on a capillary where it can be read and kept away from process heat
- For small bore lines, slurries, crystallising fluids and traced or insulated piping
Key specifications
- Accuracy
- Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and the loop accuracy is set by the transmitter, the fill fluid and the capillary run
- Output signal
- Hydraulic: process pressure deflects the diaphragm and displaces fill fluid through the capillary to the transmitter sensor, so the transmitter has to be ranged for the seal's fill fluid and temperature
- Diagnostics
- The flush diaphragm removes the dead pocket a tee would create, but the capillary adds fill volume and a temperature error along its run, and it has to be routed and supported so it does not fatigue
- Pressure range
- Flange ratings ASME B16.5 Class 150, 300, 600, 900, 1500 and 2500, or EN 1092-1 PN 6, 40, 63, 100 and 160, in process sizes 1/2 in. to 1-1/2 in. (DN 10 to DN 40)
- Variants
- Diaphragm in 316L, Alloy C-276, tantalum, Alloy 400, Nickel 201, Alloy 20, Alloy 600, Alloy B, titanium Gr. 4, Alloy C-22, duplex 2205 or 2507, Zirconium 702; upper housing 316L; flange in carbon steel or 316 stainless
- Application
- General purpose pressure and level measurement on small bore process lines, chemical feed lines, crystallising or polymerising fluids, and traced or insulated piping where a pocket would plug
A flanged seal for the small line, mounted where nothing can collect
The Rosemount 1199 RFW is a remote flanged diaphragm seal: a flanged body whose diaphragm sits flush against a raised-face process flange, connected by capillary to a transmitter mounted somewhere else. It is the seal for general-purpose service on small line sizes, and the reason it exists is the two words in that description — flush and remote.
Flush matters on a small line
A conventional impulse line tees off the process and runs to the transmitter. On a ½ inch line that tee is a dead pocket with a volume comparable to the pipe itself: it fills with whatever settles out of the fluid, and in a small line that pocket is a meaningful fraction of the whole cross-section. A flush flanged seal bolts directly to the flange face with its diaphragm at the process boundary, so there is no cavity between the process and the measuring element. Whatever the line carries passes across the diaphragm and continues, which is what makes this shape the right one for slurries, crystallising fluids, and small bore piping where a pocket would plug within weeks.
Remote is a decision about the transmitter, not the seal
Because the seal is remote, the transmitter is not bolted to the process flange — it sits at the end of a capillary, where it can be read, where it is not vibrating, and where it is not at process temperature. The trade is that the fill fluid now runs the length of that capillary, and the capillary is part of the measurement: it adds a volume that has to be filled, it adds a temperature error along its run, and it has to be routed and supported so it does not fatigue. A direct-mount seal has none of those problems and none of that flexibility. The choice between them is usually made by where the transmitter can physically go.
Sizes and ratings
The RFW covers ½ inch to 1½ inch (DN 10 to DN 40) process connections, in flange ratings from ASME B16.5 Class 150 through Class 2500 and EN 1092-1 PN 6 through PN 160. Flange standards include ASME B16.5, EN 1092-1, GOST 33259-15, JIS B2238 and the Chinese HG20615 and HG20592 standards, which is what makes it orderable against a plant built to a non-US specification without an adapter.
The diaphragm is the part that decides life
Diaphragm material is offered across a wide list — 316L stainless, Alloy C-276, tantalum, Alloy 400, Nickel 201, Alloy 20, Alloy 600, Alloy B, titanium Grade 4, Alloy C-22, duplex 2205 and 2507, Zirconium 702 — with the upper housing in 316L stainless and the flange in carbon steel or 316 stainless. That list is not decoration: the diaphragm is a thin metal membrane that has to flex for years without cracking, and it is the only barrier between the process and the fill fluid. A seal whose diaphragm is chosen for corrosion resistance but not for the flexing it will see is a seal that fails by pinhole, and the failure shows up as a transmitter reading that slowly goes wrong rather than as a leak anyone notices.
Where it fits
General-purpose pressure and level measurement on small bore process lines, chemical feed lines, crystallising or polymerising fluids, and any service where the transmitter needs to be remote from a hot or inaccessible flange. It is also the standard answer for a line that is traced or insulated, since the flush diaphragm sits at the flange face and the lagging can be brought right up to it without covering a pocket.
Manufacturer reference: Rosemount 1199 Diaphragm Seal Systems Product Data Sheet 00813-0100-4016, RFW remote flanged seal model components, and the 1199 quick start guide.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and the loop accuracy is set by the transmitter, the fill fluid and the capillary run |
| Output signal | Hydraulic: process pressure deflects the diaphragm and displaces fill fluid through the capillary to the transmitter sensor, so the transmitter has to be ranged for the seal's fill fluid and temperature |
| Diagnostics | The flush diaphragm removes the dead pocket a tee would create, but the capillary adds fill volume and a temperature error along its run, and it has to be routed and supported so it does not fatigue |
| Pressure range | Flange ratings ASME B16.5 Class 150, 300, 600, 900, 1500 and 2500, or EN 1092-1 PN 6, 40, 63, 100 and 160, in process sizes 1/2 in. to 1-1/2 in. (DN 10 to DN 40) |
| Variants | Diaphragm in 316L, Alloy C-276, tantalum, Alloy 400, Nickel 201, Alloy 20, Alloy 600, Alloy B, titanium Gr. 4, Alloy C-22, duplex 2205 or 2507, Zirconium 702; upper housing 316L; flange in carbon steel or 316 stainless |
| Application | General purpose pressure and level measurement on small bore process lines, chemical feed lines, crystallising or polymerising fluids, and traced or insulated piping where a pocket would plug |
| Mounting | Flush against a raised-face process flange, with the transmitter remote on a capillary. Flange standards ASME B16.5, EN 1092-1, GOST 33259-15, JIS B2238 and Chinese HG20615 / HG20592 |
| Operating temperature (°C) | Set by the fill fluid and the diaphragm material rather than by the flange; a remote seal's temperature limits are quoted for the fill fluid, with the capillary exposed to ambient along its whole run |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.