Rosemount 2051CFC Compact Orifice Flow Meter
Purchase options
From$1,572.52
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Compact orifice flow meter supplied as a leak-tested assembly of element, manifold and 2051C transmitter, with conditioning, plate or Annubar elements for 1/2 to 12 in lines.
Key features
- Compact orifice flow meter: element, manifold and 2051C transmitter supplied assembled, leak tested and calibrated
- Element options: conditioning orifice plate (C), conventional plate (P) or Annubar averaging pitot (A)
- Orifice plate elements for 1/2 to 12 in (15 to 300 mm) lines
- System reference accuracy from +/-2.25% of flow rate at 5:1 turndown (conditioning, beta 0.4)
- Reduces leak points by up to 70% compared with a conventional orifice installation
- SIL 2/3 certified to IEC 61508 with FMEDA data; 4-20 mA HART, Fieldbus or PROFIBUS PA
Key specifications
- Accuracy
- System reference accuracy at 5:1 flow turndown: +/-2.25% of flow rate for a conditioning element at beta 0.4, +/-2.45% at beta 0.65, and +/-2.50% for a conventional orifice plate
- Output signal
- 4-20 mA with HART digital signal from the 2051C transmitter; FOUNDATION Fieldbus and PROFIBUS PA available
- Power supply
- 10.5 to 42.4 Vdc with no load for the standard 4-20 mA transmitter
- Diagnostics
- Local operator interface with configuration buttons at the device, plus HART diagnostics from the 2051C transmitter
- Certifications
- SIL 2/3 certified to IEC 61508 via third party with a prior-use certificate of FMEDA data for safety instrumented functions; hazardous area approval codes available
- Measurement range
- Orifice plate elements for 1/2 to 12 in (15 to 300 mm) lines; primary element options are a conditioning orifice plate (C), a conventional orifice plate (P) or an Annubar averaging pitot tube (A)
A flow meter that arrives as one piece
The Rosemount 2051CFC is a compact orifice flow meter: a primary element that clamps between existing flanges, a manifold, and a 2051C differential pressure transmitter, assembled, leak tested and calibrated before it ships. The point of the assembly is not that the parts are better than buying them separately — it is that nobody has to join them on site.
Three element choices under one model
Code C is the conditioning orifice plate, whose four-hole pattern removes most of the straight-run requirement. Code P is a conventional orifice plate. Code A is an Annubar averaging pitot tube, for the large-line cases where a disc is impractical. Same transmitter, same manifold, three different answers to how the flow should be captured.
The accuracy you get, and the turndown it assumes
At 5:1 flow turndown, system reference accuracy is ±2.25% of flow rate for a conditioning element at beta 0.4, ±2.45% at beta 0.65, and ±2.50% for a conventional orifice plate. Those figures carry the usual assumption that the installation has the straight run it needs; the conditioning element is what buys the freedom to do without it, at a small cost in the beta 0.65 case.
What 'leak tested' is worth
The assembly is documented as reducing leak points by up to 70% compared with a conventional orifice installation, where the plate sits between flange unions with welded taps on each side. Fewer joints is fewer places for a hydrocarbon line to weep, and on a steam line it is fewer places to lag and inspect.
Sizes, output and safety
Orifice plate elements from half-inch to 12 in (15 to 300 mm). The 2051C transmitter supplies 4-20 mA with HART, operating from 10.5 to 42.4 Vdc with no load, with FOUNDATION Fieldbus and PROFIBUS PA available. SIL 2/3 certification to IEC 61508 is available with a prior-use certificate of FMEDA data for safety instrumented functions, and the local operator interface gives configuration buttons at the device rather than requiring a communicator.
Where it fits
Steam headers, gas lines, utility flows and process lines where a DP measurement is wanted without a construction project. The compact format is also the practical choice where the line is already flanged and nobody wants to cut it — the element goes in the gap.
Manufacturer reference: Rosemount DP Flow Meters and Primary Elements Product Data Sheet, 00813-0100-4484, and the Rosemount Compact Flowmeters Reference Manual.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | System reference accuracy at 5:1 flow turndown: +/-2.25% of flow rate for a conditioning element at beta 0.4, +/-2.45% at beta 0.65, and +/-2.50% for a conventional orifice plate |
| Output signal | 4-20 mA with HART digital signal from the 2051C transmitter; FOUNDATION Fieldbus and PROFIBUS PA available |
| Power supply | 10.5 to 42.4 Vdc with no load for the standard 4-20 mA transmitter |
| Diagnostics | Local operator interface with configuration buttons at the device, plus HART diagnostics from the 2051C transmitter |
| Certifications | SIL 2/3 certified to IEC 61508 via third party with a prior-use certificate of FMEDA data for safety instrumented functions; hazardous area approval codes available |
| Measurement range | Orifice plate elements for 1/2 to 12 in (15 to 300 mm) lines; primary element options are a conditioning orifice plate (C), a conventional orifice plate (P) or an Annubar averaging pitot tube (A) |
| Application | Compact differential pressure flow meter for gas, liquid and steam, supplied as a complete assembly of primary element, manifold and 2051C transmitter |
| Mounting | Primary element clamps between existing raised-face flanges, so no spool piece or welded taps are needed; the complete assembly is leak tested and calibrated before shipment and reduces leak points by up to 70% |
| Material of construction | 316 stainless steel primary element, manifold and transmitter wetted parts |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer