Overview
14-conductor ribbon cable sub-assembly linking the CPU board to the power supply board in a Rosemount liquid analysis transmitter.
Key features
- Fourteen conductor ribbon cable sub-assembly connecting the CPU board to the power supply board inside a Rosemount liquid analysis transmitter
- Emerson lists it against the Rosemount 1057 triple channel transmitter, and distributor catalogues also offer it for the 1056 dual-input analyzer - because those listings do not come from the same source, confirm fitment against the instrument's own model code and manual
- It is an internal wear item rather than an accessory: the connector latch breaks after a few removals, an insulation-displacement contact goes resistive after flexing, or a conductor is pulled at the edge - all three invisible on inspection and none repairable in place
- One conductor of fourteen failing means a single function misbehaves rather than a dead instrument, which is the intermittent fault that responds to a tap on the enclosure
- Reseller listings for the family note that retired products cannot be ordered, so for a critical analyser the sensible position is to hold one on the shelf rather than depend on next-day delivery of a legacy assembly
- Routing matters: fold it along the crease the original had, and observe the pin-1 marking at both ends, because a 14-way connector inverted into its header will seat and will not work
Key specifications
- Accuracy
- No electrical specification of its own in the published data. What it does is carry power and signals a few centimetres between two boards inside the enclosure, so a degraded cable shows up as an intermittent fault rather than as a measurement error
- Output signal
- Not applicable. 14 conductors with an insulation-displacement connector at each end; the pin-1 marking must be observed at both ends, because a 14-way connector inverted into its header will seat and will not work
- Diagnostics
- Three failures account for a ribbon cable replacement and none is visible on inspection: a connector latch that cracks after a few removals and leaves the cable held by nothing, an insulation-displacement contact that goes resistive after the cable is flexed at the wrong angle, and conductors pulled at the edge when the cable is tugged instead of the connector. One conductor of fourteen failing makes a single function misbehave rather than killing the instrument - the intermittent fault that responds to a tap on the enclosure. Reseller listings for this family note that retired products cannot be ordered, so a critical analyser deserves one of these on the shelf
- Pressure range
- Not applicable - an internal wiring sub-assembly with no process connection and no wetted parts
- Application
- Internal spare for a Rosemount liquid analysis transmitter, bought when the CPU-to-power-supply interconnect has been disturbed during board service or when an intermittent fault has been traced to it. Not part of a new analyser specification
- Mounting
- Internal to the transmitter, connecting the CPU board to the power supply board. Fold it along the crease the original had: ribbon cable is flexible in one axis and stiff in the other, and routing a new cable against that crease puts a permanent shear load on the outermost conductors
A fourteen-conductor ribbon cable is a wear item inside a transmitter
The Rosemount 24224-00 is a sub-assembly ribbon cable — 14 conductor — connecting the CPU board to the power supply board inside a Rosemount liquid analysis transmitter. Emerson lists it against the Rosemount 1057 triple channel transmitter, and distributor catalogues also offer it for the 1056 dual-input analyzer; because those two listings do not come from the same source, confirm the fitment against the instrument's own model code and manual before ordering rather than from a catalogue cross-reference.
It is worth being clear about what this is, because a page like this usually disappoints people looking for a specification. There is no accuracy, no range and no rating: it is a length of flat cable with two insulation-displacement connectors, and its purpose is to carry power and signals between two boards that are a few centimetres apart.
Why a ribbon cable is bought at all
Internal wiring fails in three ways, and all three are reasons this part exists as a stocked item:
A connector latch breaks. Ribbon connectors on a board usually retain by friction plus a small latch. A technician who has removed the board twice has handled that latch twice, and on the third removal it cracks. The cable is then held in by nothing and the instrument develops an intermittent fault that responds to a tap on the enclosure — the classic signature.
A conductor crimps loose at the connector. The insulation-displacement contact pierces the flat conductor rather than being soldered to it. That joint is mechanically sound when made properly and becomes resistive after vibration or after being flexed at the wrong angle. One conductor of fourteen, so the symptom is a single function misbehaving rather than a dead instrument.
Someone pulled it instead of the connector. A board is removed, the cable is tugged, and the conductors nearest the edge take the strain. The cable still looks fine, still seats, and works until the fractured strand opens with temperature.
None of those failures are visible on inspection and none of them are repairable in place. Replacing the cable is the whole repair, which is why it is a part number rather than a splice.
What to check before ordering
The instrument, not the description. the phrase "14-pin CPU to PS ribbon" describes a family of assemblies across analyser generations, and the two the sources name — 1057 and 1056 — are different instruments. Take the model code from the nameplate, find the board interconnect in that instrument's manual, and match the part number from there.
Availability risk. Reseller listings for this family carry the note that retired products cannot be ordered, and a spare that cannot be bought is a shutdown with a part number. If a 1056 or 1057 is carrying a critical measurement — a chlorine residual, a boiler conductivity, a discharge pH — the sensible position is to hold one of these on the shelf rather than to assume next-day delivery on a legacy assembly.
The other end. If the fault is intermittent, the cable is the first suspect but not the only one: the same symptom can come from the board connector's solder joints or from the board itself. Before ordering, reseat both ends and flex the cable gently while watching the reading — a fault that appears on flex is the cable; one that appears on pressure at the connector is the joint.
Handling
Ribbon cable is flexible in one axis and stiff in the other. Fold it the way it was folded — the crease in the original is the memory of the assembly, and a new cable routed against that crease puts a permanent shear load on the outermost conductors. Observe the pin-1 marking at both ends; a 14-way connector inverted into its header will usually seat, and will not work.
Power off and discharge before handling the boards, and take the usual antistatic precautions: the CPU board this cable serves is the most static-sensitive item in the enclosure.
Where it fits
Maintenance stock for a liquid analysis transmitter where the internal interconnect has been disturbed during service, or where an intermittent fault has been traced to it. If you are specifying a new analyser, this part is not part of the decision; if you are keeping an installed one running, it is the least expensive item in the spares cabinet and one of the few that turns a board-level diagnosis into a five-minute repair.
Manufacturer reference: Emerson product page for the Rosemount 24224-00 sub-assembly ribbon cable, 14-pin, for the instrument compatibility listing, with the analyser's own manual for the board interconnect and part number confirmation.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | No electrical specification of its own in the published data. What it does is carry power and signals a few centimetres between two boards inside the enclosure, so a degraded cable shows up as an intermittent fault rather than as a measurement error |
| Output signal | Not applicable. 14 conductors with an insulation-displacement connector at each end; the pin-1 marking must be observed at both ends, because a 14-way connector inverted into its header will seat and will not work |
| Diagnostics | Three failures account for a ribbon cable replacement and none is visible on inspection: a connector latch that cracks after a few removals and leaves the cable held by nothing, an insulation-displacement contact that goes resistive after the cable is flexed at the wrong angle, and conductors pulled at the edge when the cable is tugged instead of the connector. One conductor of fourteen failing makes a single function misbehave rather than killing the instrument - the intermittent fault that responds to a tap on the enclosure. Reseller listings for this family note that retired products cannot be ordered, so a critical analyser deserves one of these on the shelf |
| Pressure range | Not applicable - an internal wiring sub-assembly with no process connection and no wetted parts |
| Application | Internal spare for a Rosemount liquid analysis transmitter, bought when the CPU-to-power-supply interconnect has been disturbed during board service or when an intermittent fault has been traced to it. Not part of a new analyser specification |
| Mounting | Internal to the transmitter, connecting the CPU board to the power supply board. Fold it along the crease the original had: ribbon cable is flexible in one axis and stiff in the other, and routing a new cable against that crease puts a permanent shear load on the outermost conductors |
| Operating temperature (°C) | Governed by the transmitter enclosure it lives in. Handle with power off and discharged, and take antistatic precautions - the CPU board this cable serves is the most static-sensitive item in the enclosure |
| Measuring range | Not applicable. Emerson lists this sub-assembly against the Rosemount 1057 triple channel transmitter, and distributor catalogues also offer it for the 1056 dual-input analyzer; the two listings do not come from the same source, so confirm fitment from the instrument's model code and its manual before ordering |