Rosemount 2555 Solids Level Switch
Purchase options
From$353.75
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Capacitance probe level switch for low-dielectric bulk solids, with active/inactive probe lengths, build-up-immune shielding and probes to 20 m.
Key features
- Capacitance (RF) point level switch for bulk solids, built for low-dielectric media and for high temperature, mechanical stress and tensile load
- The probe has an ACTIVE length that senses and an INACTIVE length that only extends reach - the split is specified, which is how the switching point lands where the process needs it
- Active shield technology keeps the RF measurement unaffected by product build-up on the probe, answering the electrical weakness of capacitance
- Rod probes to 2.5 m with an extension tube, rope probes to 20 m; rope tensile limits 4 kN (2555R), 10 kN (2555V) and 40 kN (2555P)
- Sensitivity is chosen from an 8-band capacitance table 0.5 to 35 pF, with the horizontal rule that the measured difference should be more than 50 percent above the setting
- Where one bin holds several materials without recalibration, the sensitivity must be set for the material with the LOWEST dielectric constant
Key specifications
- Accuracy
- Not an analogue measurement - a point switch that trips on the RF capacitance change between the probe and the silo wall. Sensitivity is selected from a published 8-band table, 0.5 to 35 pF, against the measured capacitance difference
- Output signal
- Switching output for covered and uncovered state. Supply options include 21 to 230 Vac at 1.5 VA and 21 to 230 Vdc at 1.5 W; the electronics can be integral or separated and connected to the probe by cable
- Diagnostics
- Active shield technology keeps the RF measurement unaffected by product build-up on the probe. For horizontal mounting the capacitance difference between uncovered and covered should be more than about 50 percent above the sensitivity setting; for vertical rope mounting that is not required because capacitance rises progressively. Where one bin holds several materials without recalibration, set sensitivity for the material with the lowest dielectric constant
- Pressure range
- Process pressure is set by the probe, process connection and sliding sleeve, with the sleeve screws torqued to 20 Nm to establish the seal and hold process pressure; the mechanical ratings are stated at 104 F (40 C)
- Variants
- Rod versions 2555S, 2555M and 2555E with bending limits of 125 Nm, 525 Nm and 525 Nm at the mounting; rope versions 2555R, 2555P and 2555V with tensile limits of 4 kN, 40 kN and 10 kN. Probe length to 98.4 in (2.5 m) with a rod extension tube or 787 in (20 m) with an extension rope
- Application
- Low-dielectric bulk solids where a vibratory switch gives a weak or unreliable response, tall silos needing a rope probe, high mechanical load where a rod would bend, and installations where build-up is expected but the geometry does not bridge
The probe has two lengths, and only one of them measures
The Rosemount 2555 is a capacitance point level switch for bulk solids, built for low-dielectric media and for conditions that break mechanical switches: high temperature, high mechanical stress and high tensile load. It works by measuring the capacitance between the probe and the silo wall over RF, and switches when material rising around the probe increases that capacitance.
The detail that makes this a design instrument rather than a part number is that the probe has an active length and an inactive length, and only the active length senses.
Active and inactive: putting the switching point where you want it
The active length sits inside the silo and generates the electrical field between the probe and the wall. The inactive length exists only to extend the probe's overall reach. That split solves several installation problems with one idea:
- Reach past a long mounting nozzle without making the nozzle part of the measurement.
- Clear the silo wall where the mounting point is too close to it for a reliable field.
- Put the switching level precisely where the process needs it, regardless of where the flange happens to be.
- Make the height adjustable with an inactive length and a sliding sleeve.
This is why two instruments that look similar can behave completely differently: the same electronics with a different active/inactive split is a different measurement, and the split is specified rather than assumed.
Build-up, which is the classic weakness of capacitance — and the shield that answers it
A capacitance switch measures a dielectric in the field around the probe, so a coating of product on the probe changes the measurement. That is the failure mode that has historically limited the technology in sticky bulk solids. This instrument addresses it with active shield technology: the shielded section keeps the RF measurement unaffected by product build-up on the probe, so a coated probe does not read as a covered one.
It is worth being precise about what each technology can and cannot fix. A vibrating fork's problem with caking is mechanical — material bridges the gap between the tines and locks them, and no electronics can see through that. Capacitance's problem is electrical — a coating shifts the dielectric — and shielding is a genuine electrical answer to it. That is why the capacitance probe can be the right choice in a silo where build-up is expected but bridging is not.
Length: 2.5 m of rod, 20 m of rope
Probe length reaches up to 98.4 in (2.5 m) with a rod extension tube, or up to 787 in (20 m) with an extension rope. The rope versions are for tall silos where a rigid rod is not practical, and they carry their own mechanical limits — 4 kN tensile on the 2555R, 10 kN on the 2555V and 40 kN on the 2555P. On the rod versions the bending limits at the mounting are 125 Nm for the 2555S and 525 Nm for the 2555M and 2555E, with lower limits at the second load point. Those numbers are what a full silo of heavy material actually applies, and they are rated at 104 °F (40 °C).
Sensitivity is a table, not a knob position
Commissioning is a measurement, not a guess: the capacitance difference between the uncovered and covered probe is determined, and the sensitivity setting is chosen from a published table — eight bands from 0.5 pF to 35 pF, with separate columns for horizontal and vertical mounting. The rule attached to the table is the part worth remembering: for horizontal mounting the measured difference should be well above the setting, roughly more than 50 percent above it, while for vertical rope mounting that is not required because capacitance rises progressively as material fills.
The rule for a silo that holds more than one material
Where different materials are measured in the same bin without recalibration, the sensitivity must be set for the material with the lowest dielectric constant (DK). That is not an average or a compromise — it is the only setting that will still detect the weakest-signal material, and it trades away some resolution on the others. Silos that alternate between products are common in feed mills, cement plants and chemical storage, so this rule is not an edge case: it is a decision made when the silo is commissioned and rarely revisited.
Where it fits
Low-DK bulk solids where a vibratory switch gives a weak or unreliable response, tall silos needing a rope probe, high mechanical load where a rod would bend, and installations where build-up is expected but the geometry does not bridge. Together with the paddle, fork and rod switches, it completes the four-way choice: mechanical, vibratory, and electrical — and the electrical one is the only one whose sensing element can be shielded against the material it measures.
Manufacturer reference: Rosemount 2555 Solids Level Switch Reference Manual 00825-0100-2555 for the RF capacitance principle, active and inactive lengths, sensitivity tables and mechanical load ratings.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not an analogue measurement - a point switch that trips on the RF capacitance change between the probe and the silo wall. Sensitivity is selected from a published 8-band table, 0.5 to 35 pF, against the measured capacitance difference |
| Output signal | Switching output for covered and uncovered state. Supply options include 21 to 230 Vac at 1.5 VA and 21 to 230 Vdc at 1.5 W; the electronics can be integral or separated and connected to the probe by cable |
| Diagnostics | Active shield technology keeps the RF measurement unaffected by product build-up on the probe. For horizontal mounting the capacitance difference between uncovered and covered should be more than about 50 percent above the sensitivity setting; for vertical rope mounting that is not required because capacitance rises progressively. Where one bin holds several materials without recalibration, set sensitivity for the material with the lowest dielectric constant |
| Pressure range | Process pressure is set by the probe, process connection and sliding sleeve, with the sleeve screws torqued to 20 Nm to establish the seal and hold process pressure; the mechanical ratings are stated at 104 F (40 C) |
| Variants | Rod versions 2555S, 2555M and 2555E with bending limits of 125 Nm, 525 Nm and 525 Nm at the mounting; rope versions 2555R, 2555P and 2555V with tensile limits of 4 kN, 40 kN and 10 kN. Probe length to 98.4 in (2.5 m) with a rod extension tube or 787 in (20 m) with an extension rope |
| Application | Low-dielectric bulk solids where a vibratory switch gives a weak or unreliable response, tall silos needing a rope probe, high mechanical load where a rod would bend, and installations where build-up is expected but the geometry does not bridge |
| Mounting | Installed through the vessel wall or a nozzle. Active and inactive probe lengths let the installation clear a long mounting nozzle, stand off a nearby silo wall, place the switching level precisely, or become height-adjustable with a sliding sleeve. For vertical rope mounting the material must cover the probe by 4 to 8 in (10 to 20 cm) |
| Operating temperature (°C) | Probe and electronics rated for high-temperature service as part of the extreme-condition design; cable and wiring insulation must be rated at least 194 F (90 C), and the electronics ambient range is -40 to +80 C |