Rosemount 2555 Solids Level Switch

Part number2555ManufacturerEmerson

Purchase options

From$353.75

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Capacitance probe level switch for low-dielectric bulk solids, with active/inactive probe lengths, build-up-immune shielding and probes to 20 m.

Key features

  • Capacitance (RF) point level switch for bulk solids, built for low-dielectric media and for high temperature, mechanical stress and tensile load
  • The probe has an ACTIVE length that senses and an INACTIVE length that only extends reach - the split is specified, which is how the switching point lands where the process needs it
  • Active shield technology keeps the RF measurement unaffected by product build-up on the probe, answering the electrical weakness of capacitance
  • Rod probes to 2.5 m with an extension tube, rope probes to 20 m; rope tensile limits 4 kN (2555R), 10 kN (2555V) and 40 kN (2555P)
  • Sensitivity is chosen from an 8-band capacitance table 0.5 to 35 pF, with the horizontal rule that the measured difference should be more than 50 percent above the setting
  • Where one bin holds several materials without recalibration, the sensitivity must be set for the material with the LOWEST dielectric constant

Key specifications

Accuracy
Not an analogue measurement - a point switch that trips on the RF capacitance change between the probe and the silo wall. Sensitivity is selected from a published 8-band table, 0.5 to 35 pF, against the measured capacitance difference
Output signal
Switching output for covered and uncovered state. Supply options include 21 to 230 Vac at 1.5 VA and 21 to 230 Vdc at 1.5 W; the electronics can be integral or separated and connected to the probe by cable
Diagnostics
Active shield technology keeps the RF measurement unaffected by product build-up on the probe. For horizontal mounting the capacitance difference between uncovered and covered should be more than about 50 percent above the sensitivity setting; for vertical rope mounting that is not required because capacitance rises progressively. Where one bin holds several materials without recalibration, set sensitivity for the material with the lowest dielectric constant
Pressure range
Process pressure is set by the probe, process connection and sliding sleeve, with the sleeve screws torqued to 20 Nm to establish the seal and hold process pressure; the mechanical ratings are stated at 104 F (40 C)
Variants
Rod versions 2555S, 2555M and 2555E with bending limits of 125 Nm, 525 Nm and 525 Nm at the mounting; rope versions 2555R, 2555P and 2555V with tensile limits of 4 kN, 40 kN and 10 kN. Probe length to 98.4 in (2.5 m) with a rod extension tube or 787 in (20 m) with an extension rope
Application
Low-dielectric bulk solids where a vibratory switch gives a weak or unreliable response, tall silos needing a rope probe, high mechanical load where a rod would bend, and installations where build-up is expected but the geometry does not bridge