Rosemount 3051S Coplanar Pressure Transmitter
Purchase options
From$1,281.25
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Coplanar platform pressure transmitter with Ultra performance of +/-0.025% of span, 200:1 rangedown and 15-year stability, for DP, gauge or absolute pressure.
Key features
- Coplanar platform pressure transmitter for differential, gauge or absolute pressure
- Ultra performance: +/-0.025% of span on ranges 2 to 4, 200:1 rangedown, 15-year stability and warranty
- Classic performance: +/-0.035% of span, 150:1 rangedown; Ultra for Flow: +/-0.04% of reading to 200:1 turndown
- 4-20 mA with HART standard, HART Revision 7, FOUNDATION Fieldbus or WirelessHART available
- 10.5 to 42.4 Vdc no load, or 12 to 42.4 Vdc with the Advanced HART Diagnostics Suite
- Accepts three- and five-valve manifolds, primary elements and 1199 remote seals without an adaptor
Key specifications
- Accuracy
- Ultra: +/-0.025% of span on ranges 2 to 4 (below 10:1 span, +/-[0.005 + 0.0035(URL/Span)]% of span), +/-0.05% on range 5 and +/-0.09% on ranges 0 and 1; Classic: +/-0.035% of span; Ultra for Flow: +/-0.04% of reading up to 8:1 DP turndown
- Output signal
- 4-20 mA with HART digital signal as standard; HART Revision 7 with the Advanced HART diagnostics suite; FOUNDATION Fieldbus and WirelessHART available
- Power supply
- 10.5 to 42.4 Vdc with no load; 12 to 42.4 Vdc when the Advanced HART Diagnostics Suite is fitted
- Diagnostics
- Advanced HART diagnostics suite (DA2) with HART Revision 7, or the FOUNDATION Fieldbus diagnostics suite (D01)
- Certifications
- Intrinsic safety, explosion-proof, Type n and FISCO approvals available for ATEX, IECEx, FM, CSA and other authorities by code
- Measurement range
- Ranges 0 through 5 with up to 200:1 rangedown on Ultra and 150:1 on Classic performance classes
The platform underneath the flow and level families
The Rosemount 3051S Coplanar is the pressure transmitter that everything else in this family is built on. It measures differential, gauge or absolute pressure on the Coplanar platform, and that platform is why the same transmitter body accepts a manifold, an orifice or Annubar primary element, or a remote diaphragm seal without an adaptor between them.
Three performance classes, three different questions
Ultra gives ±0.025% of span on ranges 2 to 4 with 200:1 rangedown and a fifteen-year stability and warranty statement. Classic gives ±0.035% of span with 150:1 rangedown. Ultra for Flow is specified differently — ±0.04% of reading up to 8:1 DP turndown from the URL — because on a flow application the error that matters scales with reading, not with span. Choosing between them is a question about how tight the control loop needs to be, not about which is better.
What the twenty-five thousandths buys
A transmitter at ±0.025% of span is not simply 'more accurate' than one at ±0.035%. At wide spans the difference is small; at the narrow spans that follow from a high rangedown, the fixed term in the accuracy equation starts to dominate, and the formula quoted on the datasheet — ±(0.005 + 0.0035[URL/Span])% of span below 10:1 — tells you exactly how it degrades. That formula is the honest part of the specification, and it is the number to use when the installation will run at 20:1.
Stability as a maintenance number
Fifteen-year stability is a claim about calibration intervals, not about the first day in service. If it holds, the transmitter does not need to come off the line for a bench check every two years, which on a unit with a hundred of them is the difference between a maintenance campaign and a walk-around.
Protocols and power
4-20 mA with HART is standard, with HART Revision 7 available (which requires the Advanced HART diagnostics suite), and FOUNDATION Fieldbus or WirelessHART as alternatives. Supply is 10.5 to 42.4 Vdc with no load, or 12 to 42.4 Vdc when the Advanced HART Diagnostics Suite is fitted — a small detail that matters if a 12 V loop is being reused.
From the transmitter to a complete measurement
The Coplanar flange takes a three- or five-valve manifold directly, so impulse piping is reduced to two short nipples or eliminated. The same body mounts to a 1195 or 3051CFP primary element, or to a 1199 remote seal when the process needs a diaphragm in contact with it. That is the practical meaning of 'platform': the transmitter is bought once and configured into whichever measurement the process demands.
Manufacturer reference: Rosemount 3051S Series Pressure Transmitters Product Data Sheet.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Ultra: +/-0.025% of span on ranges 2 to 4 (below 10:1 span, +/-[0.005 + 0.0035(URL/Span)]% of span), +/-0.05% on range 5 and +/-0.09% on ranges 0 and 1; Classic: +/-0.035% of span; Ultra for Flow: +/-0.04% of reading up to 8:1 DP turndown |
| Output signal | 4-20 mA with HART digital signal as standard; HART Revision 7 with the Advanced HART diagnostics suite; FOUNDATION Fieldbus and WirelessHART available |
| Power supply | 10.5 to 42.4 Vdc with no load; 12 to 42.4 Vdc when the Advanced HART Diagnostics Suite is fitted |
| Diagnostics | Advanced HART diagnostics suite (DA2) with HART Revision 7, or the FOUNDATION Fieldbus diagnostics suite (D01) |
| Certifications | Intrinsic safety, explosion-proof, Type n and FISCO approvals available for ATEX, IECEx, FM, CSA and other authorities by code |
| Measurement range | Ranges 0 through 5 with up to 200:1 rangedown on Ultra and 150:1 on Classic performance classes |
| Application | Coplanar platform pressure transmitter for differential, gauge or absolute pressure, accepting manifolds, primary elements and remote diaphragm seals directly |
| Mounting | Coplanar flange accepts three- and five-valve manifolds directly, or mounts to an integral orifice element, Annubar primary element or 1199 remote seal |