Overview

MultiVariable DP transmitter with static pressure and Pt100 temperature input: 0.04 percent of reading DP accuracy and mass flow calculated inside the transmitter.

Key features

  • MultiVariable transmitter measuring differential pressure, static pressure and process temperature in one device
  • Calculates mass and energy flow internally from the three inputs, so the control system receives a finished mass flow rather than raw DP
  • Ultra for Flow performance: +/-0.04 percent of READING DP accuracy with 200:1 rangedown and 15-year stability
  • Measurement type codes: 1 DP + static + temperature, 2 DP + static, 3 DP + temperature, 4 DP only
  • Temperature input is Pt100 RTD -200 to 850 C and the sensor is ordered separately; types 1 and 3 require it, types 2 and 4 require none
  • Update rates: DP 22 per second, calculated variables 22 per second, RTD interface 1 per second

Key specifications

Accuracy
Ultra for Flow performance: +/-0.04 percent of READING differential pressure accuracy, 200:1 rangedown, 15-year stability and 15-year limited warranty. Reading-based accuracy does not degrade as a proportion of the value when the span is set wider than the operating point
Output signal
4-20 mA with HART, or FOUNDATION Fieldbus, carrying differential pressure, static pressure, temperature and calculated mass or energy flow. Calculated variables update at 22 per second, the DP channel at 22 per second and the RTD interface at 1 per second
Diagnostics
The three measurements are taken at one device and compensated together inside it, so the control system receives a finished mass flow rather than raw DP plus two correction inputs. The compensation is what keeps a steam or gas reading honest as pressure and temperature move through the day
Pressure range
Differential pressure ranges per the 3051S coplanar offering, with static pressure limits of 4,500 psig (310 bar) or 6,092 psig (420 bar) available as CD options. Static pressure range 5 is a sealed gauge sensor
Variants
Measurement type codes: 1 DP + static + temperature, 2 DP + static, 3 DP + temperature, 4 DP only. RTD input is required for types 1 and 3 and must be none for types 2 and 4. Isolating diaphragm in 316L, Alloy C-276, tantalum or gold-plated 316L
Application
Steam and gas flow where density compensation is worth having, natural gas and utility flow metering, boiler feedwater and steam headers, and any DP flow point that would otherwise need separate pressure and temperature transmitters