Rosemount 3300 Series Guided Wave Radar Level and Interface Transmitter
Purchase options
From$2,074.66
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Two-wire guided wave radar transmitter that reports level and interface from one probe. It reads the top surface and, on a two-liquid tank, the boundary below it, and outputs HART, Modbus or WirelessHART.
Key features
- Level and interface from one probe, one process penetration
- Two-wire loop power, configured over HART or the local display
- Coaxial, twin lead and single lead probes, including cut-to-fit lengths
- Remote housing, mounting brackets and probe accessories
- HART, Modbus or WirelessHART with a THUM adapter
- Reads the top surface and the interface below it on two-liquid tanks
Key specifications
- Measurement principle
- Guided wave radar (time domain reflectometry); second echo for interface
- Process temperature
- -40 to 150 C (-40 to 302 F) on the standard version
- Pressure rating
- Set by the process connection and probe selection
- Process connection
- Threaded or flanged; coaxial, twin lead or single lead probe
- Enclosure rating
- IP66/IP67; aluminium or stainless steel housing
- Output signal
- 4-20 mA HART, Modbus, or WirelessHART with a THUM adapter
What this transmitter is
The 3300 is a two-wire guided wave radar instrument that measures two things at once. A pulse travels down a probe and reflects from the first surface it meets; the remaining energy continues and reflects again from the interface below. The transmitter reads both echoes, so one probe gives the top level and the interface under it.
Why the interface matters
On a separator or a crude tank the useful number is often not how full the vessel is but where the boundary between the two liquids sits. A single 3300 replaces a level device plus a separate interface measurement, and it does so through one process penetration.
Probes and installation
- Coaxial, twin lead or single lead probes, with cut-to-fit versions so a probe can be shortened on site to the vessel's real height.
- Threaded or flanged process connections, with remote housing and mounting brackets where the vessel is hard to reach.
- Two-wire loop power and configuration from HART or the local display.
Output
HART over 4-20 mA, Modbus, or WirelessHART when a THUM adapter is fitted — which is what makes the instrument usable on a tank with no spare wiring.
Limits worth knowing
Interface measurement depends on the dielectric contrast between the two liquids: the wider the gap, the more reliable the second echo. On a thin upper layer with a similar dielectric constant, a guided wave probe still sees the top level but the interface becomes weak — that is a property of the method, not of this model.
Manufacturer reference: Emerson document 00813-0100-4811.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Guided wave radar (time domain reflectometry); second echo for interface |
| Process temperature | -40 to 150 C (-40 to 302 F) on the standard version |
| Pressure rating | Set by the process connection and probe selection |
| Process connection | Threaded or flanged; coaxial, twin lead or single lead probe |
| Enclosure rating | IP66/IP67; aluminium or stainless steel housing |
| Output signal | 4-20 mA HART, Modbus, or WirelessHART with a THUM adapter |
| Power supply | Two-wire, loop powered |
| Wetted materials | 316L stainless steel and Alloy C-276 probes; PTFE-covered options |
| Diagnostics | Echo curve and amplitude diagnostics over HART; local display available |
| Certifications | Explosion-proof, flameproof and intrinsically safe approvals |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer