Rosemount 3490 Series Control Unit
Purchase options
Request a quote
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
4-20 mA and HART level and flow controller with five relays, two digital inputs and pre-programmed wet well pump routines; wall or panel mount.
Key features
- 4-20 mA and HART compatible control unit for level and flow transmitters, wall or panel mounted, in standard, differential and logging versions
- Pre-programmed pump control routines for wet well and sump control, with energy saving overrides - the standard duty cycle that would otherwise be written and tested in a PLC
- Five freely assignable SPDT voltage-free relays, with relay 5 defaulting to a fault relay, plus two digital input ports for contact closures that override control
- Two tiers of HART support: any HART transmitter works through Universal and Common Practice commands, while a Rosemount 3100 Series transmitter gives full access to its configuration parameters from the unit's front panel
- Three enclosures: IP65 wall mount, NEMA 4X wall mount for corrosion and washdown, and a panel mount for a control room
- First power-up asks for the application type: level and pump control, open channel flow, differential level or tank volume
Key specifications
- Accuracy
- The control unit works from the transmitter's 4-20 mA or HART value, so measurement accuracy belongs to the transmitter. Control is exercised through user-entered process values and five SPDT voltage-free relays
- Output signal
- Five freely assignable SPDT voltage-free contact relays, with relay 5 defaulting to a fault relay, plus two digital input ports for contact closure signals that override the controller. Versions differ in channel output and logging, not in the control vocabulary
- Diagnostics
- Two tiers of HART support: any HART transmitter is recognised as an unknown instrument and handled through Universal and Common Practice commands, while a Rosemount 3100 Series transmitter gives full access to its configuration parameters from the front panel
- Pressure range
- Not applicable - a wall or panel mounted control unit with no process connection and no wetted parts
- Variants
- 3491 Standard Control Unit, 3492 Differential Control Unit with a second channel output, and 3493 Logging Control Unit with data logging and log download. Software release 4.00.00 and above
- Application
- Wet wells and sumps with one or two pumps, tank level with high and low alarms, open channel flow with a flume or weir, differential level across a screen or filter, and tank volume from a level reading
It asks what the application is before it asks for a setpoint
The Rosemount 3490 Series is a 4–20 mA and HART compatible control unit for level and flow transmitters — a wall or panel mounted controller that takes a transmitter's reading and does something with it. On first power-up it presents a short list of application types rather than a blank parameter tree: level and pump control, open channel flow, differential level and tank volume.
That menu is the product in one screen. A pump station's control logic is not custom engineering — it is a known pattern, and the 3490 comes with those patterns already written.
The pre-programmed routines are the reason to buy it
The control unit is described as pre-programmed with popular pump control routines for wet well and sump control, along with energy saving overrides. In a wet well that means the standard duty cycle a designer would otherwise have to implement in a PLC or in relay logic: pump start and stop levels, lead and lag pumps, alternation so one pump does not wear out first, and overrides that stop a pump running when there is nothing to pump.
None of that is difficult, and all of it takes time to write, test and document — then takes more time every time somebody changes a level. Buying a controller that already contains it is how a small pump station gets a control system without a control-system project.
Five relays and two inputs, and why that count fits
Control is provided by five SPDT voltage-free contact relays, freely assignable, and by default relay 5 is a fault relay while the others operate at user-entered process values. There are also two digital input ports for contact closures that override the controller's functions.
Count a typical wet well: pump 1, pump 2, high level alarm, and a fault output. That is four, and the fifth is the one you assign to duty assist or a second alarm. The arithmetic is not arbitrary — it matches what a small station actually needs, which is why the unit does not need expansion modules to do its job. The two digital inputs are the same argument in the other direction: a float switch, a telemetry override or a hand-off-auto signal from a panel can be wired in and given authority over the programmed behaviour.
Two tiers of HART support, and the difference is real
The control unit interrogates and programs HART transmitters, but not all of them equally:
- Any HART transmitter connects, is recognised as an unknown instrument, and is supported through the Universal and Common Practice commands.
- A Rosemount 3100 Series transmitter is recognised as a known device and gives full access to the transmitter's configuration parameters — the bottom reference, the engineering units, the whole parameter set — from the controller's own front panel.
That distinction decides whether the controller is a display and control unit or also a configuration tool. On a site with 3100 Series transmitters, an engineer can commission the whole loop from the wall-mounted unit without a laptop or a handheld; with a third-party HART device the same unit will read the primary variable and offer the universal parameters, and stop there.
Three versions and three enclosures
| Version | What it adds |
|---|---|
| 3491 Standard Control Unit | The control functions, five relays, two digital inputs |
| 3492 Differential Control Unit | A second channel output, for differential level applications |
| 3493 Logging Control Unit | Data logging with log download |
The enclosures are a separate choice: an IP65 wall mount with a weatherproof enclosure for internal or external installation, a NEMA 4X wall mount, and a panel mount with a black enclosure for a control room panel. The two wall versions are not interchangeable in a wet or chemical environment — NEMA 4X is the corrosion-resistant and washdown-rated construction, and it is the one that belongs in a pump station rather than a plant room.
Where it fits
Wet wells and sumps with one or two pumps, tank level with high and low alarms, open channel flow with a flume or weir, differential level across a screen or filter, and tank volume from a level reading. It is the right answer where a level measurement needs to drive pumps and alarms locally, without a PLC and without a controls engineer — and where the transmitter is a 3100 Series, in which case the controller is also the configuration interface for the whole loop.
Manufacturer reference: Rosemount 3490 Series Control Unit Reference Manual 00809-0100-4841 for control functions, relay assignments, pump routines, HART support tiers and mounting options.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | The control unit works from the transmitter's 4-20 mA or HART value, so measurement accuracy belongs to the transmitter. Control is exercised through user-entered process values and five SPDT voltage-free relays |
| Output signal | Five freely assignable SPDT voltage-free contact relays, with relay 5 defaulting to a fault relay, plus two digital input ports for contact closure signals that override the controller. Versions differ in channel output and logging, not in the control vocabulary |
| Diagnostics | Two tiers of HART support: any HART transmitter is recognised as an unknown instrument and handled through Universal and Common Practice commands, while a Rosemount 3100 Series transmitter gives full access to its configuration parameters from the front panel |
| Pressure range | Not applicable - a wall or panel mounted control unit with no process connection and no wetted parts |
| Variants | 3491 Standard Control Unit, 3492 Differential Control Unit with a second channel output, and 3493 Logging Control Unit with data logging and log download. Software release 4.00.00 and above |
| Application | Wet wells and sumps with one or two pumps, tank level with high and low alarms, open channel flow with a flume or weir, differential level across a screen or filter, and tank volume from a level reading |
| Mounting | Wall mount in IP65 or NEMA 4X, or panel mount. The two wall versions are not interchangeable in a wet or chemical environment: NEMA 4X is the corrosion-resistant and washdown-rated construction for a pump station |
| Operating temperature (°C) | Set by the enclosure choice: IP65 wall mount with a weatherproof enclosure for internal or external installation, NEMA 4X wall mount for corrosion and washdown, or a black panel mount enclosure for a control room panel |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer