Rosemount 405 Compact Orifice Flow Element
Purchase options
From$557.61
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Compact orifice element that clamps between existing raised-face flanges with no new pipe penetrations, self-centering, 1/2 to 8 in line sizes, beta 0.4 and 0.65.
Key features
- Compact orifice element that installs between existing raised-face flanges
- No additional pipe penetrations, no spool piece, no welded taps
- Self-centering design independent of flange rating, machined as a single cast piece
- Line sizes 1/2 to 8 in (15 to 200 mm); beta ratios 0.4 and 0.65
- Discharge coefficient uncertainty +/-0.5%; system accuracy from +/-0.85% with a 3051SFC transmitter
- Pressure retention per ANSI B16.5 Class 600 or DIN PN 100; 316 stainless steel element
Key specifications
- Measurement principle
- Differential pressure across a machined orifice; standard and conditioning (four-hole) versions available, the conditioning version removing the long straight run requirement
- Accuracy
- Discharge coefficient uncertainty +/-0.5%; system reference accuracy with a 3051SFC transmitter from +/-0.85% of volumetric flow (conditioning element, beta 0.4, liquid) to +/-2.00% (standard element, 1/2 to 1 1/2 in lines); repeatability +/-0.1%
- Pressure rating
- Pressure retention per ANSI B16.5 Class 600 or DIN PN 100, matching the flange class it is installed between
- Measurement range
- Line sizes 1/2 to 8 in (15 to 200 mm); beta ratios 0.4 and 0.65; 8:1 flow turndown
- Application
- Compact orifice primary element installed between existing raised-face flanges for liquid, gas and steam flow measurement, including retrofits where no new pipe penetration is possible
- Mounting
- Clamps between existing raised-face flanges with no additional pipe penetrations, no spool piece and no welded taps; self-centering independent of flange rating
An orifice that fits between the flanges you already have
The Rosemount 405 is a compact orifice element: a machined disc that clamps between two existing raised-face flanges. There is no new spool, no additional pipe penetration, and no welded tap — the element sits where a plate would sit, and the pressure is taken from the flange taps that are already there.
Why that matters more than it sounds
A conventional orifice installation is a small construction project: cut the line, weld a spool, drill and weld taps, pressure test, and hope the plate ends up centred. On an existing line that work means a shutdown. The 405 replaces it with a flange spread, a disc, and a torque wrench — and the element self-centres, which is the part that decides whether the measurement is right.
Centring is the accuracy story
A plate that sits off centre in a small line produces an error that can reach several percent, and it is invisible afterwards. The 405 centres itself mechanically, independent of flange rating, which is why the discharge coefficient uncertainty holds at ±0.5% rather than drifting with the installation. Machined as a single cast piece, the element also avoids the dimensional variation of an assembly.
System accuracy, when paired with a transmitter
As a complete flowmeter with a 3051SFC transmitter, system reference accuracy runs from ±0.85% of volumetric flow for a conditioning element at beta 0.4 in liquid, to ±2.00% for a standard element in half-inch to inch-and-a-half lines. Gas and steam figures are slightly worse, which is normal: the properties that enter the calculation are themselves less certain. Repeatability is ±0.1% and turndown is 8:1.
Sizes and limits
Half-inch through 8 in (15 to 200 mm), with beta ratios of 0.4 and 0.65. Pressure retention follows ANSI B16.5 Class 600 or DIN PN 100, which is also the ceiling on the flange it can be sandwiched into. The element is 316 stainless steel, and it is available in standard and conditioning versions — the conditioning pattern being the four-hole arrangement that removes the long straight run requirement.
Where it fits
Retrofits, closed-loop control points and general monitoring on lines where nobody is going to cut pipe: utility headers, existing process lines during a turnaround, and anywhere the measurement is wanted but the capital project is not.
Manufacturer reference: Rosemount 405 Compact Orifice Series Product Data Sheet, 00813-0100-4810 Rev CB.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Differential pressure across a machined orifice; standard and conditioning (four-hole) versions available, the conditioning version removing the long straight run requirement |
| Accuracy | Discharge coefficient uncertainty +/-0.5%; system reference accuracy with a 3051SFC transmitter from +/-0.85% of volumetric flow (conditioning element, beta 0.4, liquid) to +/-2.00% (standard element, 1/2 to 1 1/2 in lines); repeatability +/-0.1% |
| Pressure rating | Pressure retention per ANSI B16.5 Class 600 or DIN PN 100, matching the flange class it is installed between |
| Measurement range | Line sizes 1/2 to 8 in (15 to 200 mm); beta ratios 0.4 and 0.65; 8:1 flow turndown |
| Application | Compact orifice primary element installed between existing raised-face flanges for liquid, gas and steam flow measurement, including retrofits where no new pipe penetration is possible |
| Mounting | Clamps between existing raised-face flanges with no additional pipe penetrations, no spool piece and no welded taps; self-centering independent of flange rating |
| Material of construction | 316 stainless steel element, machined as a single cast design based on ASME/ISO corner tap geometry |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer