Rosemount 490A Optical Dissolved Oxygen Sensor

Part number490AManufacturerEmerson

No product images are published for this product yet.

Purchase options

From$1,586.46

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Optical dissolved oxygen sensor using EPA-approved luminescence quenching: 0-60 mg/L, 0.01 mg/L resolution, two-year cap, no flow dependence.

Key features

  • Optical dissolved oxygen sensor using the EPA-approved luminescence-quenching method, 0 to 60 mg/L or 0 to 600 percent saturation, with 0.01 mg/L resolution
  • It consumes no oxygen and has no electrolyte, so the sensing cap is replaced every two years rather than being recalibrated and rebuilt
  • The measurement does not need flow past the sensor: an amperometric cell consumes oxygen at its own surface and reads low in still water, which the optical method does not do
  • Measures accurately in both liquid and gas without separate calibrations, and reads accurately within 90 seconds of going from dry to wet, so a cleaned sensor is valid as soon as it is back in
  • Accuracy is 0.1 mg/L from 0 to 20 mg/L and 2 percent from 20 to 60 mg/L, with response under 45 seconds to 90 percent of final value
  • Temperature accuracy of 0.1 C is part of the oxygen measurement, because mg/L is derived from partial pressure using the solubility of oxygen, which depends on temperature

Key specifications

Accuracy
0.1 mg/L from 0 to 20 mg/L, and 2 percent from 20 to 60 mg/L - so a sensor quoted as 0.1 mg/L is that good in the lower band, which is where aeration control actually operates. Resolution 0.01 mg/L. Temperature accuracy 0.1 C, which is part of the oxygen figure because mg/L is derived from partial pressure using the solubility of oxygen, and solubility depends on temperature
Output signal
Digital Modbus over RS-485, with an M12 connector and either 0.5 ft (0.15 m) or 32.8 ft (10 m) of integral cable
Diagnostics
The failure mode to watch is a temperature element, because a failed one does not stop the oxygen reading, it makes it plausible and wrong. Otherwise the maintenance drivers are physical: biofilm on the sensing face reads as falling oxygen, which is why an anti-fouling guard, an air-blast guard and a weighted guard are offered - choose from the water, not from the catalogue
Pressure range
150 psi (10.3 bar) from +32 to +122 F (0 to +50 C). In an aeration basin at atmospheric pressure that is margin; in a pressurised line it is the difference between a reading and a leak
Application
Dissolved oxygen in wastewater aeration basins and ponds, surface water and aquaculture, where the sensing face can be cleaned on a two-year cycle rather than a weekly calibration routine. Clean, warm, low-fouling streams where someone is on site daily are still a fair application for an amperometric cell
Operating temperature (°C)
+23 to +122 F (-5 to +50 C)