Rosemount 4x5 Torque Type Power Positioner
Purchase options
From$3,701.13
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Pneumatic torque type power positioner for damper drives: 4 x 5 cylinder, 240 ft-lb stall torque, 1% repeatability, 45 to 120 psig air supply.
Key features
- Pneumatic torque type power positioner, 4 in cylinder with 5 in stroke, for damper and valve actuation
- Stall torque 240 ft-lb (325 N·m) at the recommended 100 psig air supply
- Repeatability 1.0% of full stroke; full stroke time 2 seconds or less unloaded
- Air supply 45 to 120 psig clean dry instrument air, 0.4 scfm consumption
- Characterized cam positioner with integral feedback for a linear signal-to-airflow relationship
- Wall, swivel or floor mounting; manual operator, limit switches and position transmitters available
Key specifications
- Accuracy
- Repeatability 1.0% of full stroke with the characterized cam positioner and integral feedback; full stroke time 2 seconds or less unloaded
- Output signal
- Stall torque 240 ft-lb (325 N·m) from a 4 in. cylinder with a 5 in. stroke at the recommended air supply
- Diagnostics
- On air supply failure the positioner drives to the configured full open or full closed position and holds it until air pressure is restored
- Pressure range
- Clean dry instrument air 45 to 120 psig (310 to 827 kPa gauge), 100 psig recommended; air consumption 0.4 scfm of free air
- Variants
- Manual operator available on the torque type models; limit switches and position transmitters available for feedback; large cylinder option for plants whose air supply is below 100 psig
- Application
- Pneumatic actuation of dampers, butterfly valves and jackshafts in combustion control on small packaged boilers, fired heaters and reheat or combustion air systems
The muscle between the controller and the damper
The Rosemount 4x5 torque type power positioner is a pneumatic damper drive: a 4 inch cylinder with a 5 inch stroke, a characterized cam positioner and an integral feedback linkage, packaged to move a damper, butterfly valve or jackshaft to the position the control signal asks for. It is the part of a combustion control loop that does the physical work, and on a fired heater it is the part that decides whether the fuel/air ratio actually follows the setpoint.
Why a positioner and not just a cylinder
A bare pneumatic cylinder moves when it is pressurised and stops when friction, linkage weight or duct pressure decides to stop it. A power positioner closes that loop internally: the cam and feedback arm compare the actual shaft position with the commanded signal and keep correcting, which is why the published repeatability is 1.0 percent of full stroke rather than "depends on load". The characterized cam is the other half — it lets the damper's non-linear characteristic be bent into a straight relationship between input signal and airflow, so the controller's tuning means the same thing at 10% and at 90% firing.
Torque and speed
Stall torque for this model is 240 ft-lb (325 N·m) at the recommended air supply, with a full stroke time of 2 seconds or less unloaded and air consumption of 0.4 scfm of free air. The torque figure is what selects the model against the damper: a 4x5 suits applications up to roughly that class, and the 6x10 and 8x14 models exist for the heavier shafts.
Air supply is the specification to check first
The positioner takes clean, dry instrument air from 45 to 120 psig, with 100 psig recommended. On plants whose instrument air runs below 100 psig, Emerson offers a large-cylinder option so the same torque is available at lower pressure — that option is the difference between a drive that works and one that stalls on a cold morning when the compressor is struggling.
Failure behaviour and mounting
On loss of air the positioner drives the damper to its configured failure position, full open or full closed, and holds there until air is restored: on a combustion application that is a safety function, not a convenience, and the failure direction must match the burner management philosophy. Mounting options are wall, swivel and floor, and the torque models accept a manual operator for use when air is unavailable.
Options that show up in a real installation
Limit switches and position transmitters provide the feedback the control system needs to confirm the damper actually moved, and the manual operator lets an operator position the damper during commissioning or an air outage. All of these are ordered with the drive rather than added later, because retrofitting a limit switch to a mounted damper drive is a shutdown task.
Where it fits
Small packaged boilers, fired heaters, reheat and combustion air dampers, butterfly valves and jackshafts — anywhere a pneumatic control signal has to become a repeatable mechanical position on a damper that is too heavy for a direct-mounted actuator.
Manufacturer reference: Rosemount Analytical Damper Drives Product Data Sheet, and the Hagan 4 x 5 Torque Type Power Positioner manual, Rev J.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Repeatability 1.0% of full stroke with the characterized cam positioner and integral feedback; full stroke time 2 seconds or less unloaded |
| Output signal | Stall torque 240 ft-lb (325 N·m) from a 4 in. cylinder with a 5 in. stroke at the recommended air supply |
| Diagnostics | On air supply failure the positioner drives to the configured full open or full closed position and holds it until air pressure is restored |
| Pressure range | Clean dry instrument air 45 to 120 psig (310 to 827 kPa gauge), 100 psig recommended; air consumption 0.4 scfm of free air |
| Variants | Manual operator available on the torque type models; limit switches and position transmitters available for feedback; large cylinder option for plants whose air supply is below 100 psig |
| Application | Pneumatic actuation of dampers, butterfly valves and jackshafts in combustion control on small packaged boilers, fired heaters and reheat or combustion air systems |
| Mounting | Wall, swivel or floor mounting; characterized positioner provides a straight line relationship between input signal and damper position |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer