Rosemount 644 Temperature Transmitter
Purchase options
From$387.83
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Head- and rail-mount temperature transmitter for RTD, thermocouple, mV and ohm sensors. It runs 4-20 mA with HART revision 7, supports single or dual sensor inputs, and is certified to SIL 3 for safety instrumented systems.
Key features
- Head-mount and rail-mount versions on one electronics platform
- Single or dual inputs for RTD, thermocouple, millivolt and ohm sensors
- 4-20 mA with HART revision 7
- Certified to SIL 3 (IEC 61508) by an accredited third party
- Sensor backup and drift alert on dual-input units
- Optional local LCD for head-mount housings
Key specifications
- Measurement principle
- RTD, thermocouple, millivolt and ohm measurement, single or dual input
- Accuracy
- ±0.15 C on Pt100 input; stated per sensor type
- Process temperature
- Sensor dependent; transmitter ambient -40 to 85 C (-40 to 185 F)
- Process connection
- Head-mount on the sensor connection head, or DIN rail module
- Enclosure rating
- IP66 / IP67 on head-mount housing; rail module mounts in the panel
- Output signal
- 4-20 mA with HART revision 7
What this transmitter is
The 644 takes a temperature sensor signal and turns it into a 4-20 mA value the control system can read over a long run. The same electronics are supplied in a head-mount housing, which rides on top of the sensor, or as a rail-mount module for the panel.
Sensor inputs
- Single or dual inputs for RTD, thermocouple, millivolt and ohm sensors.
- User-selectable sensor type, so one stock unit covers several sensor families.
- Dual-input units can average two sensors or keep one in reserve.
Electronics
Output is 4-20 mA with HART revision 7. Configuration and trim are done over HART, and a local LCD is available for the head-mount version when the reading has to be visible at the sensor.
Safety
The 644 is certified to SIL 3 by an accredited third-party agency under IEC 61508, which makes it usable in safety instrumented systems without a separate logic solver change.
Where it fits
Typical duty is a single temperature point on a vessel, line or furnace where the sensor lives in the field and the cable run is long enough that a direct-wired signal would drift or pick up noise.
Manufacturer reference: Emerson document 00813-0100-4728.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | RTD, thermocouple, millivolt and ohm measurement, single or dual input |
| Accuracy | ±0.15 C on Pt100 input; stated per sensor type |
| Process temperature | Sensor dependent; transmitter ambient -40 to 85 C (-40 to 185 F) |
| Process connection | Head-mount on the sensor connection head, or DIN rail module |
| Enclosure rating | IP66 / IP67 on head-mount housing; rail module mounts in the panel |
| Output signal | 4-20 mA with HART revision 7 |
| Power supply | 12 to 42.4 Vdc (HART, loop powered) |
| Wetted materials | Not wetted — the sensor is the wetted part |
| Diagnostics | Sensor backup, drift alert and open-circuit detection on dual-input units |
| Certifications | SIL 3 (IEC 61508) certified by an accredited third party |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer