Rosemount 8712 Flow Transmitter
Purchase options
From$1,334.10
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Remote-mount transmitter for Rosemount magnetic flowtubes, keeping the electronics off a hot, wet or vibrating line while delivering 4-20 mA with HART or a fieldbus output.
Key features
- Remote-mount transmitter for the Rosemount 8700 series flowtubes
- Electronics separated from a hot, wet or vibrating line
- 4-20 mA with HART; FOUNDATION Fieldbus and PROFIBUS PA versions
- Backlit display showing flow, total and diagnostics
- IP66 housing; IP68 only when mounted as the instructions require
- Dedicated shielded sensor cable
Key specifications
- Measurement principle
- Magnetic induction: the remote transmitter drives the sensor coils and converts the electrode voltage into flow
- Accuracy
- System accuracy with a matched sensor: 0.25% of rate as standard, 0.15% with the high-accuracy option
- Process temperature
- Transmitter ambient -40 to 74 C (-40 to 165 F); process limits belong to the flowtube
- Process connection
- Remote mount: the transmitter sits apart from the sensor and connects by the dedicated shielded cable
- Enclosure rating
- IP66; IP68 only when mounted as the installation guide requires
- Output signal
- 4-20 mA with HART; FOUNDATION Fieldbus and PROFIBUS PA versions available
What the 8712 is
A remote-mount transmitter for Rosemount magnetic flowtubes. The electronics sit in their own housing — on a wall, a stand or a rail — and connect to the sensor by a dedicated cable, so the part that must be read and configured is not bolted to a wet, hot or vibrating pipe.
Why remote mount
An integral transmitter is convenient until the line is at 150 C, the area is washed down daily, or the meter sits in a pit. Moving the electronics away fixes all three at once and puts the display at eye level where an operator can actually read it.
What it does
Drives the sensor coils, conditions the electrode signal, and produces flow, total and diagnostics on a backlit display. Output is 4-20 mA with HART as standard, with FOUNDATION Fieldbus and PROFIBUS PA versions for plants on a digital bus.
Installation notes
The sensor cable is part of the measurement, not just wiring: it is a specific shielded cable, cut to length, with the shield terminated as the instructions show. A substituted cable is the most common cause of a noisy reading on a remote-mounted magnetic meter.
Where it fits
Paired with the 8705 flanged, 8711 wafer or 8721 hygienic flowtubes in water, wastewater, chemical and food service, where the transmitter needs to be somewhere a person can reach it.
Manufacturer reference: Emerson 8712 installation guide and reference manual.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Magnetic induction: the remote transmitter drives the sensor coils and converts the electrode voltage into flow |
| Accuracy | System accuracy with a matched sensor: 0.25% of rate as standard, 0.15% with the high-accuracy option |
| Process temperature | Transmitter ambient -40 to 74 C (-40 to 165 F); process limits belong to the flowtube |
| Process connection | Remote mount: the transmitter sits apart from the sensor and connects by the dedicated shielded cable |
| Enclosure rating | IP66; IP68 only when mounted as the installation guide requires |
| Output signal | 4-20 mA with HART; FOUNDATION Fieldbus and PROFIBUS PA versions available |
| Power supply | 90-250 V AC or 12-42 V DC depending on the model |
| Wetted materials | Not applicable - the transmitter does not contact the process |
| Diagnostics | Sensor and process diagnostics on the display and over the protocol |
| Certifications | Hazardous-area approvals per model code |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer