Rosemount 8800D Series Vortex Flow Meter
Purchase options
From$1,939.81
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Vortex flow meter with a shedder bar and no moving parts, in wafer or flanged bodies, with an internal temperature sensor option for compensated steam and gas mass flow.
Key features
- Vortex shedding meter with a shedder bar and no moving parts
- Wafer or flanged body styles
- Internal temperature sensor and pressure input for compensated mass flow
- 4-20 mA with HART; FOUNDATION Fieldbus option
- No impulse tubing, so no condensate legs or freeze risk
- Suits steam, compressed air, gas and low-viscosity liquids
Key specifications
- Measurement principle
- Vortex shedding: the shedder bar produces alternating vortices whose frequency is proportional to velocity
- Accuracy
- ±0.65% of rate for liquids and ±1.0% of rate for gases, measured on the shedder-bar vortex frequency
- Line size range
- 1/2 in to 12 in (15 mm to 300 mm)
- Process temperature
- Up to 427 C (800 F) with the high-temperature extension, depending on the body and sensor option
- Pressure rating
- Set by the flange class and line size selected
- Process connection
- Wafer body clamped between flanges, or flanged body with the line's flange standard
What the 8800D is
A vortex flow meter: a shedder bar stands across the bore and the flow sheds alternating vortices behind it. The frequency of that shedding is proportional to velocity, so the meter counts vortices and reports flow — no moving parts, nothing to wear, and no impulse lines to freeze or plug.
Why vortex for steam and gas
Differential pressure meters need impulse tubing and a separate transmitter; a vortex meter is a single spool with the electronics on top. On saturated steam that removes the condensate legs that are the usual source of error, and on compressed gas it removes the leak paths.
Multivariable output
The 8800D can carry an internal temperature sensor and a pressure input, so the same device reports compensated mass flow as well as volumetric flow. That matters on steam, where density changes with pressure and a volumetric number alone is not the number the plant is paid on.
Installation
Needs a straight run upstream and downstream — the data sheet gives the lengths for each disturbance — and the shedder bar must be aligned with the flow. Wafer bodies fit between existing flanges; flanged bodies are used where the line cannot be spread or where the pipe class demands it.
Where it fits
Steam distribution, compressed air, natural gas, nitrogen and low-viscosity liquids in chemical, power and food plants.
Manufacturer reference: Emerson document 00813-0100-4004.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Vortex shedding: the shedder bar produces alternating vortices whose frequency is proportional to velocity |
| Accuracy | ±0.65% of rate for liquids and ±1.0% of rate for gases, measured on the shedder-bar vortex frequency |
| Line size range | 1/2 in to 12 in (15 mm to 300 mm) |
| Process temperature | Up to 427 C (800 F) with the high-temperature extension, depending on the body and sensor option |
| Pressure rating | Set by the flange class and line size selected |
| Process connection | Wafer body clamped between flanges, or flanged body with the line's flange standard |
| Output signal | 4-20 mA with HART; FOUNDATION Fieldbus option; pulse output for totalising |
| Power supply | Four-wire, 12-42 V DC or 90-250 V AC depending on the model |
| Wetted materials | 316L stainless steel shedder bar and body as standard; duplex and other alloys per model code |
| Certifications | Hazardous-area approvals per model code, including intrinsically safe and explosion-proof |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer