Overview
WirelessHART gas monitor for H2S, CO, oxygen deficiency and combustible gas, with hot-swappable 628 sensor modules that carry their own calibration.
Key features
- WirelessHART gas monitor for hydrogen sulfide (0-100 ppm), carbon monoxide (0-1000 ppm), oxygen deficiency (0-25 percent) and combustible gas (0-100 percent LEL)
- Response times published as T20, T50 and T90, not just T90: H2S reaches T50 in under 10 seconds and T90 in under 45
- Takes the 628 series hot-swappable sensor modules, changed in the field without tools, with end-of-life diagnostics on the H2S and CO sensors
- The 628 sensor retains its own calibration and can move between transmitters, but must be connected to a transmitter to be calibrated
- Power module life over 3 years with a 628EC toxic sensor and 1.5 years with a 628MP combustible sensor - the sensor type, not the radio, sets it
- IP66 is achieved with the IP filter fitted to the 628, so the rating belongs to the transmitter and sensor assembly; optional discrete output for a local alarm
Key specifications
- Accuracy
- H2S +/-3 ppm or 10 percent of reading; CO +/-6 ppm or 10 percent; O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below; combustible +/-3 percent LEL on methane and +/-5 percent LEL on hydrogen. Response times T20/T50/T90: H2S under 8/10/45 s, CO under 7/12/29 s, O2 under 2/4/15 s, combustible under 16 s T50 and 24 s T90
- Output signal
- WirelessHART to the gateway, plus an optional discrete output for activating a field alarm so a local horn does not depend on the host being reachable
- Diagnostics
- The 628 sensor retains its own calibration rather than storing it in the transmitter, so a sensor can be moved between monitors already calibrated - but calibration requires the sensor to be connected to a transmitter, so a spare cannot be calibrated on the bench alone. End-of-life diagnostics on H2S and CO give warning before a sensor stops responding
- Pressure range
- Not applicable - an ambient air gas monitor with no process connection; it samples the atmosphere around the sensor head rather than a line
- Variants
- Gas options per the 628 sensor module: 628EC electrochemical for H2S, CO and O2; 628MP for combustible gas. Power module life over 3 years with 628EC and 1.5 years with 628MP. Sensor options SS (specified and shipped with the transmitter) and UT (universal transmitter, no sensor)
- Application
- Remote and intermittent-occupancy locations where gas can accumulate unobserved: tank farms, wellheads, produced water tanks, pump and compressor skids, unmanned utility rooms and confined spaces a wired network never reached
A gas detector that alarms in seconds, and a sensor that carries its own calibration
The Rosemount 928 is a WirelessHART gas monitor for hydrogen sulfide, carbon monoxide, oxygen deficiency and combustible gas, built for the places a wired detector is too expensive to reach: remote wellheads, tank farms, pump skids, unmanned rooms. It takes the 628 series hot-swappable sensor modules, which can be changed in the field without tools.
The four gases, and the numbers that decide whether you are protected
| Gas | Range | Accuracy | T20 | T50 | T90 | Default alarm |
|---|---|---|---|---|---|---|
| H2S | 0–100 ppm | ±3 ppm or 10% of reading | <8 s | <10 s | <45 s | 10 ppm |
| CO | 0–1000 ppm | ±6 ppm or 10% of reading | <7 s | <12 s | <29 s | 100 ppm |
| O2 | 0–25% by volume | ±0.5% of reading (≥4%), ±1.2% (<4%) | <2 s | <4 s | <15 s | 19.5% |
| Combustible | 0–100% LEL | ±3% LEL (methane), ±5% LEL (hydrogen) | — | <16 s | <24 s | 20% LEL |
Datasheets usually quote only T90, and T90 alone hides the part that matters. T50 is when the reading has travelled half its distance to the true value, which is roughly when a controller looking at a threshold can be expected to act. For H2S this monitor reaches T50 in under ten seconds, so an alarm at 10 ppm is credible within the time a person at the source would take to notice — that is the difference between a detector that warns and one that records.
The calibration lives in the sensor, and that has a consequence
The 628 module retains its own calibration information, not the transmitter's. A sensor can be moved from one 928 to another and arrives already calibrated, which is genuinely useful for a fleet of monitors on a site. The other half of the same fact is the constraint: calibration requires the sensor to be connected to a transmitter, so a spare sensor cannot be calibrated on the bench by itself. The swap procedure and the calibration procedure are different tasks, and only the first one can be done standing at the post.
Power module life is set by the sensor, not the radio
The published figures are more than three years with a 628EC toxic sensor and 1.5 years with a 628MP combustible sensor. That factor of two is not a battery quality difference: an electrochemical toxic sensor draws microamps, while a combustible sensor runs a heated element at milliamps. The practical consequence is that a site with a mix of the two types has two replacement intervals to plan, and one of them is half as long as the other. The figure also depends on wireless update rate, display settings and ambient conditions, so it is a planning number rather than a commitment.
Wireless, which is the reason this product exists
The monitor joins a WirelessHART network, so the cost that disappears is the cable — the trench, the conduit, the penetration and the labour — rather than the instrument. On a tank farm or a remote well pad that is the whole business case. There is also an optional discrete output for driving a local alarm, which matters because a wireless alarm that depends on the gateway and the host is not the same as a horn at the post.
The IP rating is a system property
IP66 is achieved with the IP filter fitted to the 628 sensor. That phrasing is deliberate: the ingress protection belongs to the transmitter-plus-sensor assembly, not to the housing alone, so a sensor fitted without its filter is not an IP66 device however well the cover is closed. The transmitter operates from -40 to +140 °F (-40 to +60 °C) ambient, with the combustible sensor limited to +122 °F (+50 °C).
Where it fits
Remote and intermittent-occupancy locations where gas can accumulate and nobody is watching: tank farms, wellheads, produced-water tanks, pump and compressor skids, unmanned utility rooms, and confined spaces that a fixed wired network never reached. End-of-life diagnostics on the H2S and CO sensors give warning before a sensor stops responding, which on an unmanned site is the difference between planned and unplanned maintenance.
Manufacturer reference: Rosemount 928 Wireless Gas Monitor Product Data Sheet 00813-0100-4928 for gas ranges, response times, sensor options and power module life; 928 reference manual for installation and calibration.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | H2S +/-3 ppm or 10 percent of reading; CO +/-6 ppm or 10 percent; O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below; combustible +/-3 percent LEL on methane and +/-5 percent LEL on hydrogen. Response times T20/T50/T90: H2S under 8/10/45 s, CO under 7/12/29 s, O2 under 2/4/15 s, combustible under 16 s T50 and 24 s T90 |
| Output signal | WirelessHART to the gateway, plus an optional discrete output for activating a field alarm so a local horn does not depend on the host being reachable |
| Diagnostics | The 628 sensor retains its own calibration rather than storing it in the transmitter, so a sensor can be moved between monitors already calibrated - but calibration requires the sensor to be connected to a transmitter, so a spare cannot be calibrated on the bench alone. End-of-life diagnostics on H2S and CO give warning before a sensor stops responding |
| Pressure range | Not applicable - an ambient air gas monitor with no process connection; it samples the atmosphere around the sensor head rather than a line |
| Variants | Gas options per the 628 sensor module: 628EC electrochemical for H2S, CO and O2; 628MP for combustible gas. Power module life over 3 years with 628EC and 1.5 years with 628MP. Sensor options SS (specified and shipped with the transmitter) and UT (universal transmitter, no sensor) |
| Application | Remote and intermittent-occupancy locations where gas can accumulate unobserved: tank farms, wellheads, produced water tanks, pump and compressor skids, unmanned utility rooms and confined spaces a wired network never reached |
| Mounting | Fixed installation at the point of potential gas accumulation, typically at breathing height for toxic gases and near the potential release for combustible. The 628 module is changed in the field without tools |