Rosemount 928 Wireless Gas Monitor

Part number928ManufacturerEmerson

Purchase options

From$1,497.65

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

WirelessHART gas monitor for H2S, CO, oxygen deficiency and combustible gas, with hot-swappable 628 sensor modules that carry their own calibration.

Key features

  • WirelessHART gas monitor for hydrogen sulfide (0-100 ppm), carbon monoxide (0-1000 ppm), oxygen deficiency (0-25 percent) and combustible gas (0-100 percent LEL)
  • Response times published as T20, T50 and T90, not just T90: H2S reaches T50 in under 10 seconds and T90 in under 45
  • Takes the 628 series hot-swappable sensor modules, changed in the field without tools, with end-of-life diagnostics on the H2S and CO sensors
  • The 628 sensor retains its own calibration and can move between transmitters, but must be connected to a transmitter to be calibrated
  • Power module life over 3 years with a 628EC toxic sensor and 1.5 years with a 628MP combustible sensor - the sensor type, not the radio, sets it
  • IP66 is achieved with the IP filter fitted to the 628, so the rating belongs to the transmitter and sensor assembly; optional discrete output for a local alarm

Key specifications

Accuracy
H2S +/-3 ppm or 10 percent of reading; CO +/-6 ppm or 10 percent; O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below; combustible +/-3 percent LEL on methane and +/-5 percent LEL on hydrogen. Response times T20/T50/T90: H2S under 8/10/45 s, CO under 7/12/29 s, O2 under 2/4/15 s, combustible under 16 s T50 and 24 s T90
Output signal
WirelessHART to the gateway, plus an optional discrete output for activating a field alarm so a local horn does not depend on the host being reachable
Diagnostics
The 628 sensor retains its own calibration rather than storing it in the transmitter, so a sensor can be moved between monitors already calibrated - but calibration requires the sensor to be connected to a transmitter, so a spare cannot be calibrated on the bench alone. End-of-life diagnostics on H2S and CO give warning before a sensor stops responding
Pressure range
Not applicable - an ambient air gas monitor with no process connection; it samples the atmosphere around the sensor head rather than a line
Variants
Gas options per the 628 sensor module: 628EC electrochemical for H2S, CO and O2; 628MP for combustible gas. Power module life over 3 years with 628EC and 1.5 years with 628MP. Sensor options SS (specified and shipped with the transmitter) and UT (universal transmitter, no sensor)
Application
Remote and intermittent-occupancy locations where gas can accumulate unobserved: tank farms, wellheads, produced water tanks, pump and compressor skids, unmanned utility rooms and confined spaces a wired network never reached