Ir al contenido principal
Vendido y enviado por Sproh

Monitor de gas inalámbrico Rosemount 928

Número de pieza928FabricanteEmerson

Opciones de compra

Desde1497,65 US$

Disponibilidad
Consultar disponibilidad Original
Seleccionar opción

Configurable: elija las opciones para construir el número de pieza exacto.

Proveedor independiente

Sproh es un proveedor independiente y no es un distribuidor autorizado ni representante oficial de Rosemount o Emerson.

Resumen

Monitor de gas WirelessHART para H2S, CO, deficiencia de oxígeno y gas combustible, con módulos de sensor 628 intercambiables en caliente que conservan su propia calibración.

Especificaciones principales

Exactitud
H2S +/-3 ppm or 10 percent of reading; CO +/-6 ppm or 10 percent; O2 +/-0.5 percent of reading at or above 4 percent and +/-1.2 percent below; combustible +/-3 percent LEL on methane and +/-5 percent LEL on hydrogen. Response times T20/T50/T90: H2S under 8/10/45 s, CO under 7/12/29 s, O2 under 2/4/15 s, combustible under 16 s T50 and 24 s T90
Señal de salida
WirelessHART to the gateway, plus an optional discrete output for activating a field alarm so a local horn does not depend on the host being reachable
Diagnósticos
The 628 sensor retains its own calibration rather than storing it in the transmitter, so a sensor can be moved between monitors already calibrated - but calibration requires the sensor to be connected to a transmitter, so a spare cannot be calibrated on the bench alone. End-of-life diagnostics on H2S and CO give warning before a sensor stops responding
Rango de presión
Not applicable - an ambient air gas monitor with no process connection; it samples the atmosphere around the sensor head rather than a line
Variantes
Gas options per the 628 sensor module: 628EC electrochemical for H2S, CO and O2; 628MP for combustible gas. Power module life over 3 years with 628EC and 1.5 years with 628MP. Sensor options SS (specified and shipped with the transmitter) and UT (universal transmitter, no sensor)
Aplicación
Remote and intermittent-occupancy locations where gas can accumulate unobserved: tank farms, wellheads, produced water tanks, pump and compressor skids, unmanned utility rooms and confined spaces a wired network never reached
Ver todas las especificaciones