Rosemount 975MR Flame Detector
Purchase options
From$1,591.76
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Triple infrared QuadSense flame detector for hydrocarbon fires: 300 ft range, 100 x 95 degree field of view, SIL3 compatible.
Key features
- Triple infrared (IR3) QuadSense flame detector for hydrocarbon fuel and gas fires, without the hydrogen channel
- Detection up to 300 ft (90 m) for gasoline and n-heptane, 207 ft for diesel and kerosene, 185 ft for alcohol
- Field of view 100 x 95 degrees - the widest in the 975 range, shared with the UV/IR models; the HR is narrower at 80 x 80
- Response: under 2 s at 131 ft, 10 s at 300 ft, under 1 s ultra-fast at 100 ft, 50 ms for an LPG/air explosion at 66 ft
- Operating range -76 to +185 F (-60 to +85 C), SIL3 compatible, hazardous area certified, factory calibrated
- Power at 24 Vdc: 60 mA (1.4 W) without heater, up to 280 mA (7.6 W) in standard heater mode with alarm
Key specifications
- Accuracy
- Detection at the highest sensitivity on a 1 ft2 pan fire: gasoline and n-heptane 300 ft (90 m), diesel and kerosene 207 ft (63 m), alcohol 185 ft (55 m); coverage area 68,200 ft2 (6,336 m2)
- Output signal
- Alarm and fault outputs to the fire and gas system with analog voltage output for the ultra-fast and high-speed modes; 24 Vdc at 60 mA (1.4 W) without heater
- Diagnostics
- Smart field of view integrity test reports a blocked or dirty window as a fault; SIL3 compatible, certified for hazardous areas, and heater modes take consumption to 280 mA (7.6 W) with alarm
- Pressure range
- Not applicable to the sensing function; the detector is housed for hazardous area service and bracket mounted, not installed in the process
- Variants
- 975MR with QuadSense triple infrared; six sensitivity ranges; field of view 100 degrees horizontal by 95 degrees vertical, the widest in the 975 range and shared with the UV/IR models
- Application
- Hydrocarbon fuel and gas fire detection in tank farms, loading racks, turbine and compressor enclosures and solvent areas, where a wide area must be covered per detector and welding, sunlight or hot exhaust must not alarm it
The standard IR3 flame detector, with the widest field of view in the range
The Rosemount 975MR is the baseline QuadSense model: three infrared bands compared against each other to detect hydrocarbon fuel and gas fires while rejecting the false alarms that a single-band detector cannot. It is the version to specify when the hazard is a conventional hydrocarbon fire and hydrogen is not in the picture — and it has the widest field of view in the 975 range, a figure it shares with the UV/IR models.
Range and coverage
On a 1 ft² (0.1 m²) pan fire at the highest sensitivity, the 975MR sees gasoline and n-heptane at 300 ft (90 m), diesel and kerosene at 207 ft (63 m), alcohol at 185 ft (55 m). The published coverage is 68,200 ft² (6,336 m²) — a volume of 15.8 million cubic feet — which is the figure that decides how many detectors a tank farm or a turbine hall actually needs.
Field of view is where it differs from the HR
The 975MR has a 100 degree horizontal by 95 degree vertical field of view. The 975HR, which uses the same IR3 element, narrows to 80 by 80 for conventional fuels because its hydrogen channel imposes a different optical arrangement. So the MR covers more of a room per unit, and the HR trades some of that coverage for hydrogen detection. Six sensitivity ranges let either model be matched to the environment without changing part number.
Three response times, three different questions
Standard response is typically under 2 seconds at 131 ft (40 m) and 10 seconds at 300 ft (90 m). Ultra-fast response is under 1 second at 100 ft (30 m) on the analog voltage output. High-speed response is 50 ms for a 1 ft (0.3 m) LPG/air explosion at 66 ft (20 m). The first number is the one for a pool fire across a plant; the last is the one that matters when the hazard is an explosive release.
Power, environment, approval
Power at 24 Vdc runs from 60 mA (1.4 W) in normal operation without a heater to 280 mA (7.6 W) in standard heater mode with alarm — so the heater roughly doubles the load and has to be in the loop calculation. The operating range is -76 to +185 °F (-60 to +85 °C) with non-condensing humidity to 100 percent, which is the range that covers an LNG site and a desert terminal with the same part. The detector is SIL3 compatible, certified for hazardous areas, factory calibrated, and carries the smart field-of-view integrity test that reports a blocked window as a fault instead of quietly losing coverage.
Where it fits
Fuel storage and tank farms, loading racks, turbine and compressor enclosures, paint and solvent areas, and any hydrocarbon hazard where the detection has to cover a wide area per detector and where a welding arc, sunlight or a hot exhaust must not produce an alarm. Where hydrogen is present as well, the 975HR is the same detector with that channel added.
Manufacturer reference: Rosemount 975 Flame Detectors Product Data Sheet, 975MR detection ranges and general specifications.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Detection at the highest sensitivity on a 1 ft2 pan fire: gasoline and n-heptane 300 ft (90 m), diesel and kerosene 207 ft (63 m), alcohol 185 ft (55 m); coverage area 68,200 ft2 (6,336 m2) |
| Output signal | Alarm and fault outputs to the fire and gas system with analog voltage output for the ultra-fast and high-speed modes; 24 Vdc at 60 mA (1.4 W) without heater |
| Diagnostics | Smart field of view integrity test reports a blocked or dirty window as a fault; SIL3 compatible, certified for hazardous areas, and heater modes take consumption to 280 mA (7.6 W) with alarm |
| Pressure range | Not applicable to the sensing function; the detector is housed for hazardous area service and bracket mounted, not installed in the process |
| Variants | 975MR with QuadSense triple infrared; six sensitivity ranges; field of view 100 degrees horizontal by 95 degrees vertical, the widest in the 975 range and shared with the UV/IR models |
| Application | Hydrocarbon fuel and gas fire detection in tank farms, loading racks, turbine and compressor enclosures and solvent areas, where a wide area must be covered per detector and welding, sunlight or hot exhaust must not alarm it |
| Mounting | Bracket mounted, with a field of view limiter available as an accessory; factory calibrated for immediate use in an existing detection system |
| Operating temperature (°C) | -76 to +185 F (-60 to +85 C) operating and storage, non-condensing relative humidity up to 100% |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer